Unit Specifications
Volts
240V
Phase / Hz
1 ph / 50 Hz
Electrical Rating
Amps
13.8 Amps
Electrical Connection
IEC Power Cord with 3 Pin Plug
15 Amp (into standard GPO 240
Volt)
Elements
Rated
1500 watt x 2
Microprocessor Control Relay
PCB (SKCM325) Access via
compatible RS232
Control PCB
Overtemp Protection
Electronic cutout @ 5°C above set
point
Temperature Control
Incremental 1°C – 70°C
Factory set at 70°C
Secondary Overtemp Protection Hight Limit
Auto reset Bi-Metallic Disc 80°C
Doors
Bi-parting, protruding 330mm out
when open.
Door Gasket
Silicon Rubber
Materials
Cabinet
304/4 stainless steel
Air Vent
Automatic Damper Control, to be
vented to outside atmosphere.
Air Filter (mm)
150mm x 150mm x 15mm -
washable
Air Circulation
Air Bleed Off
Automatic Damper Control