background image

10

TROUBLESHOOTING

All repairs must be performed by qualified persons. The device contains electrical compo-
nents that can only be repaired by a qualified electrician.

Problem

Cause 

Action

The pump 
will not 
run

No power supply

Check cables, plugs, sockets and fuses

The motor is overheated

Check if the water temperature is too high or if 
the pump is clogged. Eliminate the cause.

The residual current  
device has tripped

Reset the RCD. Contact a qualified electrician if 
the RCD trips regularly.

The motor is faulty

Contact an authorised service representative

The pump 
runs, but 
delivers 
no liquid

Suction opening is clogged Clear the suction opening
The pump sucks air

Tilt the pump when it is submersed into the liq-
uid. Switch the pump on and off several times 
to remove the air.

The pump is clogged

Clean the pump

The pump 
gives in-
sufficient  
water

Lifting head too high

Do not exceed the max. permitted head

Pressure pipe diameter too 
small

Use a larger pressure pipe

Pressure pipe is clogged

Clear the pressure pipe

Suction opening is clogged Clear the suction opening
The pressure pipe is bent

Straighten out the pressure pipe

Pressure pipe leakage

Seal the pressure pipe and all connections

Noisy 
pump

The pump sucks air

Make sure the water level is adequate
Tilt the pump when it is submersed into the 
liquid

Pump 
running  
continu-
ously

Float body blocked

Clean the float body

Switch set incorrectly

Adjust the switch correctly

Pump is 
always 
off

Float body blocked

Clean the float body

Water level too low

MAINTENANCE

Before Use

Make sure there is no damage to cables or housing.

After Use

Clean the outside of the pump and run it for a while with clean water in a bucket/con-
tainer to clean the inside.

Storage

The pump must be stored in a frost-free place, since it might contain water which can 
burst the pump when the water freezes.

Summary of Contents for SVQ250F

Page 1: ...Modell Malli Model SVQ250F 750F 1500F 88 792 56 58 BRUKSANVISNING EN FI SE S nkbar pump INSTRUCTION MANUAL Submersible Pump K YTT OHJEET Upotettava pumppu...

Page 2: ...grant innan du anv nder apparaten och spara den f r framtida bruk SE HUOMIO Lue k ytt ohjeet huolellisesti ennen kuin otat laitteen k ytt si ja s ilyt ohjeet tulevaa k ytt varten FI NOTE Please read t...

Page 3: ...Pumpen skall kontinuerligt vervakas under drift Uttag som pumpen str mf rs rjs fr n ska vara skyddade av en jordfelsbrytare med max utl sningsstr m 30mA ANV NDNINGSOMR DEN Sandblandat vatten dock ej s...

Page 4: ...tt Rensa pumpen Pumpen ger f r lite vatten F r h g pumph jd verskrid inte h gsta till tna pumph jd F r liten trycklednings diameter Anv nd gr vre tryckledning Igensatt tryckledning Rensa tryckledninge...

Page 5: ...5 m 5 m 5 m Max partikelstorlek 15 mm 25 mm 10 mm verhettningsskydd Bimetall Bimetall Bimetall M rksp nning 230V 50Hz 230V 50Hz 230V 50Hz Effekt 250W 750W 1500W Vikt 9 5 21 27 Tekniska data Prestandak...

Page 6: ...ytt n Pumppua tulee jatkuvasti valvoa k yt n aikana Pistorasia jossa pumppua k ytet n tulee olla varustettuna 30mA laukaisuvirralla olevalla vikavirtasuojalla K YTT KOHTEET Hiekansekaista vett ei kuit...

Page 7: ...unut Puhdista pumppu Pumppu pumppaa liian v h n nestett Liian suuri nostokorkeus l ylit sallittua nostokorkeutta Liian pieni letkun halkaisija K yt suurempaa letkua Tukkeutunut letku Puhdista letku Im...

Page 8: ...a 5 m 5 m 5 m Max hiukkaskoko 15 mm 25 mm 10 mm Ylikuumenemissuoja Bimetalli Bimetalli Bimetalli Nimellisj nnite 230V 50Hz 230V 50Hz 230V 50Hz Teho 250W 750W 1500W Paino 9 5 21 27 TEKNISET TIEDOT SUOR...

Page 9: ...powered from shall be protected with a residual current device with a max tripping current of 30mA Applications For water mixed with sand no grains larger than specified though wastewater during flood...

Page 10: ...p gives in sufficient water Lifting head too high Do not exceed the max permitted head Pressure pipe diameter too small Use a larger pressure pipe Pressure pipe is clogged Clear the pressure pipe Suct...

Page 11: ...5 m Max particle size 15 mm 25 mm 10 mm Overheating protection Bimetal Bimetal Bimetal Rated voltage 230V 50Hz 230V 50Hz 230V 50Hz Power 250W 750W 1500W Weight 9 5 21 27 Technical data Performance cu...

Page 12: ...Malmbergs Elektriska AB PO Box 144 SE 692 23 Kumla SWEDEN Phone 46 19 58 77 00 Fax 46 19 57 11 77 info malmbergs com www malmbergs com MJ JA JZ 151210...