background image

MJ-JA-131007

Wireless online smoke alarm

Model: LM-101LD

63 022 41-42

insTruCTion ManuaL

Malmbergs Elektriska aB, po Box 144, sE-692 23 kumla, sWEDEn   

phone: +46 (0)19 58 77 00     fax: +46 (0)19 57 11 77     [email protected]     www.malmbergs.com

EN

The wireless online smoke alarm can be included in a same 
system by a LEarn button. When one of the detectors 
emits the high frequency digital signal (433.92MHz), the 
others receive the same signal and will alarm together to 
remind users to take measures. Easy to install and operate, 
no wiring required. suitable for both households an public 
places.

TEsT of aLarM funCTion

1.  put the DC 9v battery and 3xaa, Lr06 batteries into 

the battery box separately. Ensure that the batteries are 
installed correctly, check the plus and minus poles.

2.  The alarm indicator (red LED) flashes every 43 seconds 

when in normal working state.

3.  press the TEsT button and hold it until the TEsT indica-

tor (red LED) and online/LEarn indicator (red LED) are 
flashing, the alarm will go off to show that the smoke 
alarm is in normal working state.

onLinE/LEarn opEraTion

after finishing the test steps 1-3 above, to test if the alarm 
is in normal working state, we now move into the online/
LEarn operation. 
1.  press the LEarn button, the online/LEarn indicator will 

change from red to green, none orderly.

2.  Take one alarm as the MasTEr alarm and press the 

LEarn button until the LED turns green.

3.  Choose the second alarm as sLavE unit and press the 

LEarn button until the LED turns red. if you have more 
alarms, press all LEarn buttons until each lamp is red.

4.  press the TEsT button of MasTEr until the alarm indica-

tor (red LED) is flashing and alarming, and do not release 
the button before the online/Learn indicator is flashing 
and is sending the online signal.

5.  When the sLavE alarms receive the online signal, the 

online/Learn indicator will flash and begin to alarm too. 
When all the alarms you selected begin to alarm at the 
same time, then those alarms are in the same system.

TEsT of onLinE/LEarn opEraTion

push the TEsT button on one of the units and keep it down. 
The alarm will go off first on this unit and then, about 3 
seconds later, the other units will also sound. The reason for 
the delay is that one should be able to test them one by one 
without activating all smoke alarms.

insTaLLaTion

1.  fix the mounting plate to the ceiling with the screws 

provided (and the supplied wall plugs if necessary).

2.  Turn the main part of the alarm in clockwise direction 

and lock it into the mounting plate.

TECHniCaL paraMETErs

Rated voltage:

 

 

DC9v (for smoke detector) 
DC4.5v (for wireless online, 3xaa batteries Lr06)

Current:

  

DC9v Quiescent current in average <10µa 
DC9v alarm current in average <20ma 
DC4.5v Work current in average <120µa

Alarm decibel:

 

85dB/3 m

Alarm indicator:

 

red LED

Online/LEARN indicator: 

red/green LED

Frequency:

 433.92MHz

Control distance:

 

<60 m in open space

Temperature:

 

-10°C – +40°C

Size:

 

Ø 128×50 mm

LoW voLTagE aLarM

1.  The smoke alarm will beep every 60 seconds if the bat-

teries of 4.5v is in low power.

2.  The smoke alarm will beep every 43 seconds if the bat-

tery of 9v is in low power.

3.  please replace the battery when the battery reaches the 

end of its normal life.

poinTs for aTTEnTion

1.  avoid using the product in too hot, too cold, humid, 

dusty or smoky environment.

2.  please try to make self-test for the products once every 

week.

3.  if you find that the product is not in normal working 

state, please check the battery first, let the professional 
repair it.