gEnEraL spEciFicaTiOns

• 

Display:  

4 digits LcD with a max. reading of 1999.

• 

range control:  

automatic.

• 

polarity:  

yes.

• 

Zero adjustment:  

automatic.

• 

Overrange indication:   Display shows "OL".

• 

Low battery indication:   The display shows "

" when the battery is low.

• 

auto power off:  

15 minutes after stopping the switch or no key-input, the meter automatically    

 

enters to power off mode.

• 

safety standards:  

cE EMc/LvD. The meter is up to the standards of iEc1010. pollution degree 2.   

 

Overvoltage caT iii 600v.

• 

clamp opening size:  

42 mm.

• 

Operating environment:  Temperature 32 to 104ºF (0ºc to 40ºc), humidity < 85 % rH.

• 

storage environment:   Temperature -4 to 140ºF (-20ºc to 60ºc), humidity <95 % rH.

• 

power:  

2x1.5v aaa batteries.

• 

Dimension HxwxD:  

197.5x76x30 mm.

• 

weight:  

approx. 215 g (including batteries).

usagE

DC Voltage Measurement

1.  connect the black test lead to the cOM socket, and the red test lead to the red v

Ω

 socket.

2.  Turn the function switch to v .
3.  connect the test leads and check the reading.

AC Voltage Measurement

1.  connect the black test lead to the cOM socket, and the red test lead to the red v

Ω

 socket.

2.  Turn the function switch to v .
3.  connect the test leads and check the reading.

AC Current Measurement

1.  Disconnect any test leads connected to the meter.
2.  set the selector switch to desired ”2a/20a~” or ”200a/1000a~” position.
3.  Open the clamp by pressing the jaw-opening handle and insert the cable to be measured into the jaw.  

Measure only one cable at the time.

4.  close the clamp and check the reading from the LcD display.

Resistance Measurement

1.  connect the black test lead to ”cOM” socket and red test leads to the ”v

Ω

” socket.

2.  set the selector switch to “

Ω

” position.

3.  connect and check the reading.
caution: Ensure that the circuit to be tested is voltage free. Max. input overload: 250v rms. and <10 sec.

Diode, Continuity Test

1.  connect the black test lead to “cOM” socket and red test leads to the “v

Ω

” socket.

2.  set the selector switch to ”

” position and press ”sEL” key to choose function.

3.  connect and check the reading.
caution: Ensure that the circuit to be tested is ”dead”. Max. input overload: 250v rms. and <10 sec.

Summary of Contents for A908

Page 1: ...f r att s kerst lla korrekt m tning F r att undvika elektrisk chock skall m tning ske under st rsta m jliga f rsiktighet Anv nd inte instrumentet i fuktig utrymmen VERSIKT Funktionsv ljaren V Liksp n...

Page 2: ...1 Koppla den svarta m tsladden till COM uttaget och den r da till V uttaget 2 Vrid funktionsv ljaren till V l get 3 Anslut m tsladdarna och avl s m tv rdet AC str mm tning 1 Koppla bort ev m tsladdar...

Page 3: ...rms Kontinuitetstest H rbar indikering Mindre n ca 100 verbelastningsskydd 250V DC AC rms underh ll Reng ring Se till att instrument inte r anslutet till n gon m tkrets Reng r endast med fuktig trasa...

Page 4: ...mediately to ensure that the readings are correct To avoid electric shock be very cautious while measuring Do not use the meter in locations with high humidity Overview Function switch V DC Voltage me...

Page 5: ...ds and check the reading AC Voltage Measurement 1 Connect the black test lead to the COM socket and the red test lead to the red V socket 2 Turn the function switch to V 3 Connect the test leads and c...

Page 6: ...Test Audible indication less than 100 approx Overload protection 250V DC AC rms MAINTENANCE Cleaning Make sure the meter is not connected to any circuits Clean with a damp cloth and a mild detergent...

Page 7: ...varmistaaksesi oikean mittaustuloksen Mittauksen aikana on k ytett v varovaisuutta v ltt kseen s hk iskua l k yt mittaria kosteissa tiloissa YLEISPIIRRE Toimintavalitsin V Tasaj nnitemittaus V Vaihtoj...

Page 8: ...Vaihtoj nnitemittaus 1 Liit musta testijohto COM ulosottoon ja punainen testijohto V ulosottoon 2 V nn toimintavalitsin V asentoon 3 Yhdist testijohdot ja katso lukema AC virtamittaus 1 Ota testijohdo...

Page 9: ...ms Jatkuvuus testi Kuuluva indikointi Pienempi kuin n 100 Ylikuormitussuoja 250V DC AC rms HUOLTO Puhdistus Varmista ett mittari ei ole yhdistetty mink nlaiseen mittaus kohteeseen Puhdista vain kostea...

Reviews: