![Malm Fireplaces Imperial Carousel Installation Instructions Manual Download Page 4](http://html1.mh-extra.com/html/malm-fireplaces/imperial-carousel/imperial-carousel_installation-instructions-manual_3918724004.webp)
Imperial Carousel - Page 4
Hood Assembly
Position the hood on the basic unit. Secure hood to basic
unit using the 13 sheet metal screws provided.
IMPORTANT:
Failure to install these screws will result in
permanet damage to the unit and void the warranty.
Hood
Sheet Metal Screws
13- 14 x 1/2 Hex.
Basic Unit
All Screws Must Be Installed
DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERV-
ING ANOTHER APPLIANCE.
This stove must be connected to (1) a chimney complying with
the requirements for Type HT chimneys in the Standard for
Chimneys, Factory-Built, Residential Type and Building Heating
Appliance, UL 103, or (2) a code-approved masonry chimney
with a flue liner.
Chimney Connector Installation
It is required to install a 8 inch all-fuel class "A" chimney system
prior to the chimney connector installation. The connector pipe
included with the Imperial is 1 - 8" x 30" starter pipe, and 1 - 8"
x 30" slip connector. The slip connector is identified by 3 holes
at the top of the pipe. The slip connector has one flair at the top
with the 3 holes. The bottom is smooth. The starter pipe section
has flairings at both ends. The male end is always at the bottom.
Hearth Requirements
A floor protector is required to
protect the floor in front of the
fireplace opening from sparks.
The floor protector must be a
minimum of 2 1/2 inch thick com-
mon solid brick over 26 gauge
sheet metal or equivalent.
The floor protector must extend
a minimum of 16 inches in front
of the fireplace opening and 8
inches to either side of the fire-
place and 8 inches behind the
back of the unit. Refer to Figure
#3.
8"
8"
48"
54"
16"
Figure 3
54" Diameter Circle Hearth.
8" Minimum is measured from
the fire-box
8"
8"
8"
16" From Door
Simpson Dura-Vent Chimney System
It is required to use a Dura-Vent Universal Connector part
number 8874 to install the chimney connector.
1. The universal connector is installed into the support box.
The 8" x 30" slip pipe is then connected to the universal
connector.
2. The 8" x 30" starter pipe section is then slid over the slip
connector pipe. Slide the 30 inch pipe over the slip pipe
only far enough as necessary to facilitate installation of the
8" x 30" starter pipe in to the unit.
3. There must be a minimum of 2 inches of overlap between
the 8" x 30" and 8" x 30" slip connector pipe.
Metalbestos or Security
When using Metalbestos or Security chimney systems it is
required to use the Metalbestos DS-CPA Single Wall Conector
pipe. Security users must use the UP adapter.
1.Installation of the Metalbestos DS-CPA or the Security UP
adapter must be done first.
2.Attach the 8" x 30" slip connector to the DS-CPA or UP
adapter with 3 - #8 x 3/8 inch screws.
3.The 8" x 30" starter pipe section is then slid into the slip
connector pipe. Slide the 30 inch pipe into the slip pipe only
far enough as necessary to facilitate installation of the 8" x
30" starter pipe into the unit.
4.Slide the 8" x 30" pipe down onto the Imperial.
5.There must be a minimum of 2 inches of overlap between the
8" x 30" and 8" x 30" slip connector pipe.
Other Chimney Systems
There are many other manufacturer's of chimney systems. It
is beyond the scope of this publication to cover installation with
all of the different systems available. Most systems have a
method of connection to the Imperial's connector pipe. Confirm
installation procedures with your dealer or the manufacturer of
the chimney system you have purchased.
Fire Bowl
8"
Door