Glass Installation

Wear eye protection during the assembly of
this unit.  Check all glass and parts for dam-
age.  Replace any damaged parts prior to
continuing the installation.  Do not assemble
this  unit  with  any  damaged  parts.    If  you
should happen to break a glass panel, it must
only be replaced with ceramic glass.

1. The door panel has had the latch assembly

and hinges installed at the factory.  Remove
the hinges leaving the glued on plate in posi-
tion.

2. Place the lower hinge in the hole in the firebowl,

with the washer under it.

3. Insert the upper hinge into the hole at the top

of the door opening.  Holding the upper hinge
in place, slide the glass door panel into the
hinges.

4. Hold the door panel in the closed position to

allow access to the hinge screws.

5. Maintaining a 1/8" clearance to the left door

post, tighten the screws in the hinges snugly.

DO NOT OVER TIGHTEN

.  Re-adjust as

necessary for proper alignment.

6. Note that two panels have gasket material on

one edge. These pieces go on either side of
the door. Make certain that these two pieces
are  placed  completly  into  the  channel  on
either side of the door. Failure to do this will
make the rest of the glass installation impos-
sible.

7. First loosen the glass retainers.  This is a

metal  strip  secured  by  one  screw  in  the
middle.  Start with the left door panel.  The
gasket must be on the right side of the panel.

8. Slide the gasketed edge completely into the

channel on the side of the door. The left edge of
the glass should now fit into the button at the
bottom of the glass.

9. Lower the glass into the lower glass button

channel.

10. Repeat steps 8 and 9 with the right door panel.

The gasket will be on the left side of the panel
with the  not polished edge at the top.

11. The remaining panels can now be installed.

The edge that is not polished is placed at the
top.    As  each  panel  is  installed  replace  the
glass retainer in place but do not tighten.

12. After all the glass panels are installed center the

panels to reduce any gaps that may be be-
tween the glass panels.

13. Tighten the glass retainers.

Hood

Retainer
and Screw

Glass

Lower Glass
Button

Upper
Glass
Channel

Summary of Contents for Imperial Carousel

Page 1: ...is necessary to get a somewhat dry mixture to much water in the mix may cause the refractory to crack exces sively and will reduce the strength of the refractory To test for proper water content cut vertically into the mixture with the trowel push the trowel sideways to open a 3 inch deep by 2 inch wide cut in the mixture then slide the trowel back up out of the cut The cut should stay open with v...

Page 2: ...terialon one edge These pieces go on either side of thedoor Makecertainthatthesetwopieces are placed completly into the channel on either side of the door Failure to do this will maketherestoftheglassinstallationimpos sible 7 First loosen the glass retainers This is a metal strip secured by one screw in the middle Start with the left door panel The gasketmustbeontherightsideofthepanel 8 Slide the ...

Page 3: ...e chimney the measurement is 63 from the backwall and 63 to the sidewall See figure 1 page 2 For corner installation the center of the chimney is 63 See figure 2 page 2 Clearance to Non combustibles The Imperial clearance to a combustible wall may be reduced with proper wall protection Accepted methods for wall protection would allow reduction of the wall clearances For appearance if desired a non...

Page 4: ...48 54 16 Figure 3 54 Diameter Circle Hearth 8 Minimum is measured from the fire box 8 8 8 16 From Door Simpson Dura Vent Chimney System It is required to use a Dura Vent Universal Connector part number 8874 to install the chimney connector 1 The universal connector is installed into the support box The 8 x 30 slip pipe is then connected to the universal connector 2 The 8 x 30 starter pipe section ...

Page 5: ...tion method of installing the connector pipe with the male end down allows for any moisture to remain on the inside of the connector pipe IMPORTANT THE SINGLE WALLCONNECTOR PIPE MUST NEVER PASS THROUGH A COMBUSTIBLE CEILING OR WALL At first glance you may become concerned that smoke will escape the pipe and enter the room This is not how the system will work The vacum in the chimney system will al...

Page 6: ...gns of deterioration It is best to have the chimney inspected by a professional Make certain the chimney is cleaned prior to installation of this fireplace The size of the chimney should be between 36 and 96 square inches Larger chimneys should be relined to meet these requirements Incorrect sizing of the chimney may affect the draft and result in poor fireplace performance Do not install more tha...

Page 7: ...g when using this or any other wood burning appli ance A partially open window or outside air register in the vicinity of the unit would be accept able Combustion air must be supplied in con formance with the Uniform Mechanical Code Imperial Carousel Page 7 7 CAUTION NEVERUSEGASOLINE GASOLINE TYPE LANTERN FUEL KEROSENE CHAR COAL LIGHTER FLUID OR SIMILAR LIQUIDS TO START OR FRESHEN UP A FIRE IN THI...

Page 8: ...ote has accumulated it should be removed to reduce the chance of a chimney fire HOW TO REMOVE CREOSOTE 1 Clean the chimney with brushes and equipment available at local fireplace shops 2 Chemical chimney cleaners are used by adding them to the fire but they are not intended for use in chimneys already containing heavy soot deposits Rather they are intended to inhibit soot buildup They can be used ...

Reviews: