9
Appliance errors are the errors which generate the deactivation of the whole
hob.
When an appliance error is detected, all heaters are switched of
f, a beep
sounds (only if one or more heaters are active) and all displays show a ‘F’
letter
and the error code alternately.
While in error status all the heater keys are not operative .
Appliance errors
Error
(Visualization Priority Order)
Error recovery
Action
All Heater Dis
-
plays
(fore 0.5 sec./ back
0.5 sec)
Microcontroller fault
-------
App. off
F0
On/Off key emitter fault
When the fault disappears
App. off
FA
On/Off key receiver fault
When the fault disappears
App. off
FC
User interface temperature
sensor short-circuit
When the fault disappears
App. off
FE
User interface temperature
sensor open-circuit
When the fault disappears
App. off
Ft
User interface overtempera -
ture
When user interface
temperature < 90ºC
App. off
Fc
EEPROM fault
-------
App. off
FH
Microcontroller A/D converter
multiplexer fault
When the fault disappears
App. off
FJ
Ambient Light fault
When satisfactory ambi -
ent lighting is detected
App. off
FL
Microcontroller A/D converter
conversion fault
When the fault disappears
App. off
FU
Appliance errors
Summary of Contents for MH-02IS
Page 1: ...Operating and Installation Instructions Induction hobs MH 02IS MH 03IS H ng D n S D ng...
Page 2: ......
Page 16: ...16 Guide to the hob MH 02IS Heaters Control panel 1 2 3 1 2 3...
Page 19: ...19 MH 03IS Heaters Control panel Guide to the hob 1 2 3 1 3 2 4...
Page 45: ...45 H ng D n S D ng MH 02IS V ng n u B ng i u khi n 1 2 3 1 2 3...
Page 48: ...48 MH 03IS V ng n u B ng i u khi n H ng D n S D ng 1 2 4 3 1 3 2 4...
Page 63: ......