B
44
08.06
CHAPTER
PAGE
ISSUE
ELECTRIC SYSTEM TROUBLESHOOTING
ENGLISH
SECTION 2
Signal System
SECTION 2
B
- TROUBLESHOOTING
FAULTY MIXTURE OIL INDICATOR
1.
Check oil probe
-
Take oil probe out of tank, disconnect
connector and connect Tester in “ ”
-
Tester (+) terminal
coupling 1
-
Tester (-) terminal
coupling 2
-
Whilst keeping probe upright, float “A” must run
freely and position itself at the base of the probe:
continuity
-
Overturn probe: no continuity
COMPLIANT
B)
Check continuity of grounding
of black cable plugged into probe
-
Disconnect connector from probe and connect
tester “ ” (F23).
-
Tester (+) terminal
Black cable (1)
-
Tester (-) terminal
Chassis grounding
(2)
CONTINUITY
White cable between probe and digital instrument
interrupted; repair.
See “Circuit Diagram”
NOT COMPLIANT
Replace oil probe
NO CONTINUITY
Black cable interrupted; repair by providing a
jumper between black cable and grounded point
of chassis.
1
2