3.4 Checking voltage level
- Connect
Tester (DC 20 V)
to horn (3), as follows:
- Terminal (+) of tester
Blue cable (1).
- Terminal (-) of tester
Chassis grounding (2).
- Turn key “ON”.
-
Value read must be
12 V.
NOT COMPLIANT
- Blue cable between key switch and
horn is interrupted.
- Repair (see wiring diagram).
COMPLIANT
- Orange cable between left hand switch and horn is
interrupted.
- Repair.
- See “Wiring Diagram”.
- Fuel probe is faulty.
- Replace.
INDICATOR HAND ON
INSTRUMENT BOARD
DOES NOT MOVE
INDICATOR HAND IS POINTING TO “FULL” (1)
4. FUEL LEVEL INDICATOR IS NOT WORKING
4.1 Fuel probe
- Detach connector of probe.
- Provide jumper (1) between white/green cable and black
cable of three-way connector of wiring.