background image

6

Leading by professional

1. Treble protection for overheating

There are three protection devices, preventing over temperature, preventing heating 
water over heat, prevent domestic hot water over heat. If there is overheating these 
devices will stop the gas supply and working.

2.  the earlier safe ignition device

For the sake of avoiding deflagration, this device only supply minimum gas in the 
earlier ignition. 

3. Induction system for unusual combustion

When there is unusual combustion, the gas supply will be cut automatically.

4. Device for trash elimination

There are different filter screens in the machine, which can extend the product’s life.

5. Device for preventing empty-combustion

This device can induce whether there is water leakage in the heating pipe. If there is 
leakage, combustion will be cut automatically. Machine reruns after pouring the water 

according to the way to first operation.

6.  self-diagnoses device

This device can avoid system safety losing control which is caused by protection 
damage and make sure that the system operates in the safe and reliable environment. 

7. Device for blaze detection

After operation, this device detects the blaze signal any time and distinguish whether 
the present working is normal or not.

8. Safe device for water flow volume

Detect the water flow volume ( super-low water flow protection) to make sure that the 

machine works safely.

9.  other safe device

Safe device for preventing flue building up, safe device for refiring, protection for 
overpressure, automatic safe device for air pressure adjustment, safe device for 
preventing frostbite, anti-creepage protection, de-energize/water/gas protection and so 
on.. please use it without any worry.

don’t worry! we have safe device as follows

Summary of Contents for Condense

Page 1: ...MMAKTEK CONDENSING BOILER kk 03 rev no 01 04 2016 28kW User s Guide Read carefully Keep for future referance ...

Page 2: ...rent rules and instructions of manufacturer Manufacturer will not take any responsibility for those person harm and property damage causing by incorrect installation Gas boiler only use for supplying heating and hot water can not change to other use Warning Please follow the instruction of user s guide to operate the machine Manufacturer will not take any responsibility for those person harm and p...

Page 3: ... Items for safety 9 Function and use for main control panel 12 First operation 14 Turn on off the machine correctly 15 Cleaning and maintenance 16 Make sure the following items before repairing 17 Technical data 18 Appearance and dimension APPENDIX Packing List in A Whole Unit ...

Page 4: ...which is above the temperature you have set so that you can save much energy 3 Adopt multiple safe protection device Our products have the most safe protection device in the same trade Adopt equilibrium force air exhaust system in which the combustion chamber and air exhaust channels are completely hermetic It can absorb the fresh air exhaust the waste air after burning and eliminate the harm of C...

Page 5: ...De energize performance If the power breaks when the machine is running this performance will save all the orders which is saved before the power breaks it will carry out all the orders automatically as soon as the power works like before 8 Microcomputer chip controls and prevents incrustation Heat exchange system with good quality and prevent incrustation design connected modern microcomputer chi...

Page 6: ...here is leakage combustion will be cut automatically Machine reruns after pouring the water according to the way to first operation 6 Self diagnoses device This device can avoid system safety losing control which is caused by protection damage and make sure that the system operates in the safe and reliable environment 7 Device for blaze detection After operation this device detects the blaze signa...

Page 7: ... had better allocate a manostat if pressure is unstable 3 Use Except heating and D H W gas boiler can t be used in other ways 4 Check the switch for gas before use Check the middle switch connected on the gas pipe to see if there is leakage Ensure whether pressure of gas and flow volume of gas supply meet requirement of our product 5 Make sure the connecting state of the valve for heating Make sur...

Page 8: ...y and contact local gas supplier 8 Prevent frostbite in winter When heating heater must be unimpeded including water electricity gas There is a prevent frostbite device in the heater so the heater will work automatically in low temperature During freezing season or no one at home for a long period please exhaust the water in the machine and in the heating pipe cut off the gas supply and pull out t...

Page 9: ... Fire power grade sign Hot water temperature indication Operation sign works Winter mode Malfunction Display lock Anti freezing Summer mode Overheat protector Pump Water pressure switch Fan Air pressure switch Room thermostat 1 2 3 4 5 6 1 Information Indication Display 2 Mode Button 3 Up Button 4 On Off Power Button 5 Down Button 6 Reset Button Condense ...

Page 10: ... heating and hot water temperature Down button Reduce the heating and hot water temperature Reset button It will reset the malfunction and restart the gas boiler when malfunction occurs After entering the menu and set the situation press Reset Button to keep memory and quit the menu Key press on the Main control panel function and use for the main control panel The method for turning on off gas bo...

Page 11: ...lve s circuit malfuntion Ignition failure Fake fire malfuntion Gas pipe malfuntion Cold air block device malfunction Slash fire malfuntion Communication malfuntion Pipe malfunction Malfunction Reason The malfunction of air pressure or air speed NTC open circuit and short circuit NTC open circuit and short circuit The pipe water temperature is higher than 93 degree The output circuit of the gas val...

Page 12: ...range is from 30 55 C The speed of water output depends on the length of the pipe After all cold water flows out hot water will flow out 1 Pour Water For the Heating System 1 Open the valve for the pouring water turn left Open all the valves for exhausting air in each room as soon as open the valve for pouring water and then close the valves for exhausting air until the water comes out 2 When the ...

Page 13: ...ater will overflow from the condensing water outlet 1L h before using the product a water pipe must be connected to the condensing water to lead it to the floor drain FIRST OPERATON NOTICE Because of installing acreage or environment factors valve for decompression may drain some water automatically That is the reason that water in circulator has thermal expansion To connect a rubber duct with the...

Page 14: ...1 2kgf cm2 2 Not Be Used For A Short Period Gas boiler needs to be off if it won t be used for a short period Press and then the machine turns off When the gas boiler is under OFF state please keep the current and gas supply Gas boiler will run according to self protection program 3 Not Be Used For A Long Period Gas boiler needs to be off if it won t be used for a long period Press and then the ma...

Page 15: ... year Attention necessary not necessary Maintenance Check the obturator Clean the heat exchanger beyond the flue Clean the combustion chamber fan and inner pipe Check the device for electricity and gas Check the gas flow volume and pressure Check all the smoke pipes Clean the burner and exam the fire performance Check the water system Analyze combustion state Check the lubrication of components Ch...

Page 16: ... ignite Some unusual noise when start A smoke smell Bad heating effect No hot water or hot water isn t hot Way to Maintain Close the mid valve connected by gas pipe Don t turn on or off the electrical equipments and then ventilate Contact the supplier or the local after sales service department to make it repaired Use the suds termly to make sure whether there is gas leakage on the connection of t...

Page 17: ...ting frostbite system s start temperature Minimum effluent volume of D H W Maximum pressure of D H W Minimum pressure of D H W Expansion vessel capacity Expansion vessel preload capacity Maximum heating system pressure Nominal nature gas pressure PERFORMANCE Maximum heating water temperature Minimum heating water temperature Maximum D H W temperature Minimum D H W temperature D H W flowing rate T ...

Page 18: ...as Inlet G3 4 B D H W Outlet G1 2 C C W Inlet G1 2 D B F W Inlet G3 4 E W O H Outlet G3 4 F Condensate water outlet Ø18 D H W Domestic Hot Water C W Cold Water B F W Back Flow Water W O H Water Of Heating Attention 74mm is the dimension of B C D E 88mm is the dimension of A ...

Page 19: ...Packing List in A Whole Unit appendix 1 Host machine 2 Installation bag Two pothooks Two expansion bolts used for fix the pothook 3 Accessory bag One user s guide ...

Page 20: ...CONDENSING BOILER USER S GUIDE 10013 Sk No 14 A O S B Çiğli IZMIR Phone O 232 328 21 06 07 08 Fax O 232 328 04 86 www maktek com tr info maktek com tr ...