5. REGULATOR FUNCTIONS.
The regulator is equipped with a number of functions that, together with the possibility
of creating your own program, enable adjusting the regulator's work to the individual
needs of the user. Some of the functions listed below are activated after the appropriate
programming of the regulator (see
6. PROGRAMMING
and
9. SETTING TABLE
).
1.
Continuous temperature measurement function, regardless of whether
the regulator is on (regulator must be connected to the power supply)
–
parameter
d1
is set to 1.
2.
The function of controlling the refrigeration system (unit), depending on the
measured temperature
–
parameter
C9
is set to the value 0.
3.
Light signaling function for switching on the cooling (heating) operation
–
blue LED
is on.
4.
Control function of the heating system, depending on the measured temperature
–
parameter
C9
is set to 1.
5.
The stirrer or fan control function enabling the implementation of the following
variants of this control
–
depending on the
F0
parameter settings:
a.
automatic operation:
−
cyclic operation of the stirrer (fan), independent of the operating condition
of the unit (heating system),
−
stirrer operates continuously during the operation of the unit, when the unit
is switched off, the stirrer goes into cyclic operation,
−
stirrer (fan) works only when the unit (heating system) is switched on,
−
continuous stirrer (fan) operation while the regulator's operation is on (main
application in dryers),