5. REGULATOR FUNCTIONS.

 

The regulator is equipped with a number of functions that, together with the possibility 
of creating your own program, enable adjusting the regulator's work to the individual 
needs of the user. Some of the functions listed below are activated after the appropriate 
programming of the regulator (see 

6. PROGRAMMING

 and 

9. SETTING TABLE

). 

1.

 

Continuous  temperature  measurement  function,  regardless  of  whether  
the regulator is on (regulator must be connected to the power supply) 

 parameter 

d1

 is set to 1. 

2.

 

The  function  of  controlling  the  refrigeration  system  (unit),  depending  on  the 
measured temperature 

 parameter 

C9

 is set to the value 0. 

3.

 

Light signaling function for switching on the cooling (heating) operation 

 blue LED 

is on. 

4.

 

Control function of the heating system, depending on the measured temperature 

 

parameter 

C9

 is set to 1. 

5.

 

The  stirrer  or  fan  control  function  enabling  the  implementation  of  the  following 
variants of this control 

 depending on the 

F0

 parameter settings: 

a.

 

automatic operation: 

 

cyclic operation of the stirrer (fan), independent of the operating condition 
of the unit (heating system), 

 

stirrer operates continuously during the operation of the unit, when the unit 
is switched off, the stirrer goes into cyclic operation, 

 

stirrer (fan) works only when the unit (heating system) is switched on, 

 

continuous stirrer (fan) operation while the regulator's operation is on (main 
application in dryers), 

Summary of Contents for SMT-01

Page 1: ...rature measuring range between 40 OC and 120 OC control temperature range between 40 OC and 120 OC decreased by a set hysteresis measuring resolution of the temperature measurer resolution of control...

Page 2: ...er ventilator 10 A 250 V AC power supply 230 V AC 50 HZ protection class IP 55 safety class CE 3 CONSTRUCTION Regulator SMT is placed in a compact casing including all control and executive elements T...

Page 3: ...own depending on the type of regulator The regulator SMT 02H v 3 apart from cable entry through glands has a sealing connection of the front part of the casing with its back which ensures splash proof...

Page 4: ...LATOR In order to connect the regulator to the device with which it is to be controlled the following should be done prepare the hole in the refrigeration device to install the regulator place the reg...

Page 5: ...d temperature parameter C9 is set to the value 0 3 Light signaling function for switching on the cooling heating operation blue LED is on 4 Control function of the heating system depending on the meas...

Page 6: ...g visual and audible of exceeding the set temperature range parameters HA and HE This function is connected with the possibility of delaying the time of switching on the alarm system of the regulator...

Page 7: ...motoreducer The work for the control settings of the refrigeration system will be discussed below ATTENTION Parameter dE is the delay of switching on the unit and the stirrer after switching on the re...

Page 8: ...e difference at which the switching off occurs and then the unit is switched on For example if the control temperature is set to 4 OC and hysteresis to 2 OC then the unit will be switched off after re...

Page 9: ...lapses the manual operation of the stirrer is switched off ATTENTION No light signaling of the stirrer operation 7 8 when the regulator is switched off means that the automatic stirrer operation has b...

Page 10: ...e delay time of enabling this function allows for pre cooling of the milk after the start of cooling and thus not taking into account the maximum temperature when the device is started This time shoul...

Page 11: ...in the initial cooling phase Exceeding the set temperature range is signaled visually and sound In the event of activation of the alarm the buzzer is triggered cyclically every 1 minute for 5 seconds...

Page 12: ...to 120 OC every 1 0 OC 10 OC control hysteresis HI the possibility of setting the temperature from 0 2 OC to 10 OC every 0 2 OC for the range from 10 OC to 100 OC and from 1 0 OC to 10 OC every 1 0 OC...

Page 13: ...1 the possibility of setting the temperature from 40 OC to 120 OC every 1 0 OC 2 OC upper temperature of the alarm A2 the possibility of setting the temperature from 40 OC to 120 OC every 1 0 OC 12 OC...

Reviews: