MAKOT SMT-01 User Manual Download Page 13

Page 

13

 of 

13

 

 

parameters E1 and E2 

 as in setting 1, but disabling with the 

stirrer's working button causes its operation 
only during the operation of the unit 

 as in setting 1, but the button that disables 

the stirrer operation is inactive 

 continuous operation, regardless of the 

operation of the unit and times set in the 
parameters E1 and E2 

standstill time of the stirrer 

E1 

the possibility of setting the time from 1 min.  
to 60 min., every 1 min. 

15 (min.) 

working time of the stirrer 

E2 

the possibility of setting the time from 1 min.  
to 60 min., every 1 min. 

2 (min.) 

manual stirrer operation 
mode 

CP 

 continuous work 

>0 

 stirrer operation for a specified time in the 

range of from 1 min. to 60 min., every 1 minute 

5 (min.) 

delay of registering of the 
max. / min. values  
of temperature and delay  
of activation of the 
temperature alarm  

AA 

the possibility of setting the time from 0 h to  
24 h, every 0,1 h 

2 (h) 

lower temperature of the 
alarm 

A1 

the possibility of setting the temperature from  
-40 

O

C to +120 

O

C, every 1.0 

O

2 (

O

C) 

upper temperature of the 
alarm 

A2 

the possibility of setting the temperature from  
-40 

O

C to +120 

O

C, every 1.0 

O

12 (

O

C) 

sound of the alarm 

HE 

 

on

 

 off 

visual and sound alarm  
of exceeding the set 
temperature range 
(parameters A1 and A2) 

HA 

 

on

 

 off 

scaling the control sensor** 

CU 

every 0,2 

O

scalable 

value 

setting the operation of the 
limit switch of opening the 

tank’s flap

 

UU 

 closing the limit switch: raising the flap 

 opening the limit switch: raising the flap 

delay of switching on the unit  
and the stirrer after 
connecting  
the regulator to the mains or 
when power supply decay 
occurs 

dE 

from 1 s. to 999 s., every 1 s. 

5 (s.) 

display status when the 
control is switched off 

d1 

 the dot is displayed 

 the currently measured temperature is 

displayed 

return to factory settings 

FA 


 after setting "1" and turning off the 

regulator from the power supply, switching on 
again restores the factory settings and the 
parameter value goes back to "0" 

leaving the settings 

EE 

 

 

** set at the manufacturing stage (do not change without obvious need)

 

Summary of Contents for SMT-01

Page 1: ...rature measuring range between 40 OC and 120 OC control temperature range between 40 OC and 120 OC decreased by a set hysteresis measuring resolution of the temperature measurer resolution of control...

Page 2: ...er ventilator 10 A 250 V AC power supply 230 V AC 50 HZ protection class IP 55 safety class CE 3 CONSTRUCTION Regulator SMT is placed in a compact casing including all control and executive elements T...

Page 3: ...own depending on the type of regulator The regulator SMT 02H v 3 apart from cable entry through glands has a sealing connection of the front part of the casing with its back which ensures splash proof...

Page 4: ...LATOR In order to connect the regulator to the device with which it is to be controlled the following should be done prepare the hole in the refrigeration device to install the regulator place the reg...

Page 5: ...d temperature parameter C9 is set to the value 0 3 Light signaling function for switching on the cooling heating operation blue LED is on 4 Control function of the heating system depending on the meas...

Page 6: ...g visual and audible of exceeding the set temperature range parameters HA and HE This function is connected with the possibility of delaying the time of switching on the alarm system of the regulator...

Page 7: ...motoreducer The work for the control settings of the refrigeration system will be discussed below ATTENTION Parameter dE is the delay of switching on the unit and the stirrer after switching on the re...

Page 8: ...e difference at which the switching off occurs and then the unit is switched on For example if the control temperature is set to 4 OC and hysteresis to 2 OC then the unit will be switched off after re...

Page 9: ...lapses the manual operation of the stirrer is switched off ATTENTION No light signaling of the stirrer operation 7 8 when the regulator is switched off means that the automatic stirrer operation has b...

Page 10: ...e delay time of enabling this function allows for pre cooling of the milk after the start of cooling and thus not taking into account the maximum temperature when the device is started This time shoul...

Page 11: ...in the initial cooling phase Exceeding the set temperature range is signaled visually and sound In the event of activation of the alarm the buzzer is triggered cyclically every 1 minute for 5 seconds...

Page 12: ...to 120 OC every 1 0 OC 10 OC control hysteresis HI the possibility of setting the temperature from 0 2 OC to 10 OC every 0 2 OC for the range from 10 OC to 100 OC and from 1 0 OC to 10 OC every 1 0 OC...

Page 13: ...1 the possibility of setting the temperature from 40 OC to 120 OC every 1 0 OC 2 OC upper temperature of the alarm A2 the possibility of setting the temperature from 40 OC to 120 OC every 1 0 OC 12 OC...

Reviews: