8
Using the laser in vertical mode on tripod:
1)
Use the tripod mount (16) to attach the laser to the
tripod.
2)
Level vertical bubble vial as described under
“Vertical Setup.”
Slope
The
SKR60
can be inclined up to 90° to lay out
stairways and cathedral ceilings.
1)
Holding the laser in vertical position, attach laser
to the tripod using the 5/8-11 mount on the wall
mount.
2)
Unlock the adjustable slope clamp(15). Tilt the
laser 90° (the full extent you can move it) and lock.
3)
Center the bubbles to level the laser (see p.4)
4)
Unlock the adjustable slope clamp. Tilt the laser
until you reach the desired grade as shown on slope
angle index (17) and lock.
Changing the batteries
When battery power is low, the laser will stop
rotating and the laser beam will blink.
1)
The battery compartment (13) is located behind
the wall mount. Release clamp (15) to access it.
2)
Replace batteries with 3 new AA alkaline
batteries, matching polarity (– and +) as indicated in
the compartment. Replace all 3 at once.