R
epair
P 8 / 9
< 6 > Separating base from motor section
( 2 ) Take off ring spring 12 from lever 54. Remove lever 54 together with hex nut M8 from cap square neck
bolt M8x90. See Fig. 23 and Fig. 24.
( 1 ) Remove safety cover as illustrated in Fig. 2 and Fig. 3 in page 2/9 before the step in Fig. 23.
( 3 ) Take off cap square neck bolt M8x90 from blade case. The rear side of motor section has been disconnected
from base in this step. See Fig. 24.
( 4 ) Unscrew hex nut M6-10 and remove
pan head screw M6. See Fig. 25.
The motor section has been disconnected
from base completely. See Fig. 26.
Fig. 24
Fig. 23
Fig. 26
Fig. 25
Hex nut M6-10
Pan head screw M6
< Note >
Be careful, not to lose flat washer 8 which is
mounted between pipe 9 and depth guide of
base, when removing cap square neck bolt M8x90.
Pipe 9
Base
Ring spring 12
Lever 54
Lever 54
Hex nut M8
Cap square
neck bolt M8x90
Flat washer 8