![Makita MT952 Technical Information Download Page 6](http://html.mh-extra.com/html/makita/mt952/mt952_technical-information_227033006.webp)
W
iring diagram
P 6 / 7
Wiring on switch box
Bottom view
Bottom view
Inflecting the insulated terminals, connect them with
the switch terminals as illustrated in Fig. B.
Terminal
block
Switch
Fix the following lead wires with
these lead holders.
* Noise suppressor's lead wire
to be connected with terminal block
* Field's lead wire (black) to be
connected with terminal block
Pass the following lead wires between
rib A and B.
* Noise suppressor's lead wire
to be connected with switch
* Field's lead wire (white) to be
connected with switch
Rib A
Rib B
Fig. B
Right view
Fix the following lead wires
with this lead holder.
* Noise suppressor's lead wire
to be connected with switch
* Field lead wire (white) to be
connected with switch.
Do not slack these lead wires
between lead holder and switch.
Insulated terminals
to be connected with switch
have to be inflected as illustrated
in Fig. B.
Fix the lead wires of power supply
cord with this lead holder.
Field lead wire (white
Noise suppressor
Field lead wire
(white)
Right view