5
WARNING:
MISUSE or failure to follow the safety rules stated in
this instruction manual may cause serious personal
injury.
USB098-2
ADDITIONAL SAFETY RULES
FOR THE LASER
CAUTION:
•
LASER RADIATION DO NOT STARE INTO
BEAM.
•
AVOID EXPOSURE - LASER RADIATION IS
EMITTED FROM APERTURE.
•
USE OF CONTROLS OR ADJUSTMENTS OR
PERFORMANCE OF PROCEDURES OTHER
THAN THOSE SPECIFIED HEREIN MAY RESULT
IN HAZARDOUS RADIATION EXPOSURE.
CAUTION /PRECAUCIÓN
LASER RADIATION DO NOT STARE INTO BEAM
Maximum Output
< 1mW, Wavelength : 650 nm
CLASS LASER PRODUCT
RADIACIÓN LÁSER NO DIRIJA LA
VISTA HACIA EL RAYO LÁSER
COMPLIES WITH 21CFR 1040.10 AND
1040.11
AVOID EXPOSURE – LASER RADIATIONS
IS EMITTED FROM THIS APERTURE
CONFORME A 21CFR 1040.10 ET 1040.11
EVITEZ L'EXPOSITION - UN
RAYONNEMENT LASER EST EMIS PAR
CETTE OUVERTURE.
011388
INSTALLATION
Bench mounting
1
011380
When the tool is shipped, the handle is locked in the
lowered position by the stopper pin. Release the stopper
pin by simultaneously applying a slight downward
pressure on the handle and pulling the stopper pin.
WARNING:
•
Ensure that the tool will not move on the
supporting surface.
Movement of the miter saw
on the supporting surface while cutting may result
in loss of control and serious personal injury.
1
1
011383
This tool should be bolted with four bolts to a level and
stable surface using the bolt holes provided in the tool's
base. This will help prevent tipping and possible injury.
FUNCTIONAL DESCRIPTION
WARNING:
•
Always be sure that the tool is switched off and
unplugged before adjusting or checking
function on the tool.
Failure to switch off and
unplug the tool may result in serious personal injury
from accidental start-up.
Blade guard
1
010230
When lowering the handle, the blade guard rises
automatically. The blade guard returns to its original
position when the cut is completed and the handle is
raised.
WARNING:
•
Never defeat or remove the blade guard or the
spring which attaches to the guard.
An exposed
blade as a result of defeated guarding may result in
serious personal injury during operation.
In the interest of your personal safety, always maintain
the blade guard in good condition. Any irregular operation
of the blade guard should be corrected immediately.
Check to assure spring loaded return action of guard.
WARNING:
•
Never use the tool if the blade guard or spring
are damaged, faulty or removed.
Operation of
the tool with a damaged, faulty or removed guard
may result in serious personal injury.
1. Blade guard
1. Bolts
1. Stopper pin
Summary of Contents for LS1018-R