W
iring diagram
P 1
4
/1
6
Switch
Field
Noise suppressor
(if used)
rib A
rib B
rib C rib D
Fig. D-2
Route Field lead wires
into Handle section
through this groove.
Field lead wires must be
tight in Motor housing.
If Noise suppressor is used,
route Noise suppressor’s lead
wires between
rib A and rib B
.
Be careful not to put them on
Noise suppressor, ribs A and B.
Fix Field lead wires
in these Lead wire
holders.
Be careful not to put Lead wire (blue or white)
of Power supply cord on Noise suppressor
after connecting it to Terminal block.
Be careful not to put
Lead wires on the boss
and ribs A, B, C, D.
Field lead wires must be
tight in Motor housing.
Strain relief
Terminal block
Set Terminal block in Handle section
with each terminal positioned as follows:
*On Strain relief side, the terminal with which
the Lead wire of Power supply cord is connected
must be positioned.
*On Field side, the terminal with which the Field
lead wire is connected must be positioned.
boss
HS6100 & HS7100
(without Electric brake and LED light)