background image

3 ENGLISH

Vibration

The vibration total value (tri-axial vector sum) deter

-

mined according to EN62841-2-5:

Work mode: cutting wood

Vibration emission (a

h,W

) : 2.5 m/s

2

 or less

Uncertainty (K) : 1.5 m/s

2

NOTE:

 The declared vibration total value(s) has been 

measured in accordance with a standard test method 

and may be used for comparing one tool with another.

NOTE:

 The declared vibration total value(s) may also 

be used in a preliminary assessment of exposure.

WARNING:

 

The vibration emission during actual 

use of the power tool can differ from the declared val

-

ue(s) depending on the ways in which the tool is used 

especially what kind of workpiece is processed.

WARNING:

 

Be sure to identify safety measures 

to protect the operator that are based on an estima-

tion of exposure in the actual conditions of use (tak-

ing account of all parts of the operating cycle such 

as the times when the tool is switched off and when 

it is running idle in addition to the trigger time).

EC Declaration of Conformity

For European countries only

The EC declaration of conformity is included as Annex A 

to this instruction manual.

SAFETY WARNINGS

General power tool safety warnings

WARNING:

 

Read all safety warnings, instruc-

tions, illustrations and specifications provided with this 

power tool.

 Failure to follow all instructions listed below 

may result in electric shock, fire and/or serious injury.

Save all warnings and instruc-

tions for future reference.

The term "power tool" in the warnings refers to your 

mains-operated (corded) power tool or battery-operated 

(cordless) power tool.

Work area safety

1. 

Keep work area clean and well lit.

 Cluttered or 

dark areas invite accidents.

2. 

Do not operate power tools in explosive atmo-

spheres, such as in the presence of flammable 

liquids, gases or dust.

 Power tools create sparks 

which may ignite the dust or fumes.

3. 

Keep children and bystanders away while operating 

a power tool.

 Distractions can cause you to lose control.

Electrical safety

1. 

Power tool plugs must match the outlet. Never 

modify the plug in any way. Do not use any 

adapter plugs with earthed (grounded) power 

tools. 

Unmodified plugs and matching outlets will 

reduce risk of electric shock.

2. 

Avoid body contact with earthed or grounded 

surfaces, such as pipes, radiators, ranges and 

refrigerators.

 There is an increased risk of elec-

tric shock if your body is earthed or grounded.

3. 

Do not expose power tools to rain or wet con-

ditions.

 Water entering a power tool will increase 

the risk of electric shock.

4. 

Do not abuse the cord. Never use the cord for 

carrying, pulling or unplugging the power tool. 

Keep cord away from heat, oil, sharp edges 

or moving parts.

 Damaged or entangled cords 

increase the risk of electric shock.

5. 

When operating a power tool outdoors, use an 

extension cord suitable for outdoor use.

 Use of 

a cord suitable for outdoor use reduces the risk of 

electric shock.

6. 

If operating a power tool in a damp location 

is unavoidable, use a residual current device 

(RCD) protected supply.

 Use of an RCD reduces 

the risk of electric shock.

7. 

Power tools can produce electromagnetic 

fields (EMF) that are not harmful to the user.

 

However, users of pacemakers and other similar 

medical devices should contact the maker of their 

device and/or doctor for advice before operating 

this power tool.

Personal safety

1. 

Stay alert, watch what you are doing and use 

common sense when operating a power tool. 

Do not use a power tool while you are tired or 

under the influence of drugs, alcohol or med

-

ication.

 A moment of inattention while operating 

power tools may result in serious personal injury.

2. 

Use personal protective equipment. Always 

wear eye protection.

 Protective equipment such 

as a dust mask, non-skid safety shoes, hard hat or 

hearing protection used for appropriate conditions 

will reduce personal injuries.

3. 

Prevent unintentional starting. Ensure the 

switch is in the off-position before connecting 

to power source and/or battery pack, picking 

up or carrying the tool.

 Carrying power tools with 

your finger on the switch or energising power tools 

that have the switch on invites accidents.

4. 

Remove any adjusting key or wrench before 

turning the power tool on.

 A wrench or a key left 

attached to a rotating part of the power tool may 

result in personal injury.

5. 

Do not overreach. Keep proper footing and 

balance at all times.

 This enables better control 

of the power tool in unexpected situations.

6. 

Dress properly. Do not wear loose clothing or 

jewellery. Keep your hair and clothing away 

from moving parts.

 Loose clothes, jewellery or 

long hair can be caught in moving parts.

7. 

If devices are provided for the connection of 

dust extraction and collection facilities, ensure 

these are connected and properly used.

 Use of 

dust collection can reduce dust-related hazards.

8. 

Do not let familiarity gained from frequent use 

of tools allow you to become complacent and 

ignore tool safety principles.

 A careless action 

can cause severe injury within a fraction of a 

second.

Summary of Contents for HS011GZ

Page 1: ...INSTRUCTION MANUAL Cordless Circular Saw HS011G ENGLISH Original instructions Read before use ...

Page 2: ...trical and electronic appliances or batteries with household waste In accordance with the European Directive on waste electrical and electronic equip ment and on accumulators and batteries and waste accumulators and batteries as well as their adaptation to national law waste electrical equipment batteries and accumulators should be stored separately and delivered to a separate collection point for...

Page 3: ...power tools to rain or wet con ditions Water entering a power tool will increase the risk of electric shock 4 Do not abuse the cord Never use the cord for carrying pulling or unplugging the power tool Keep cord away from heat oil sharp edges or moving parts Damaged or entangled cords increase the risk of electric shock 5 When operating a power tool outdoors use an extension cord suitable for outdo...

Page 4: ...parts may result in personal injury Battery tool use and care 1 Recharge only with the charger specified by the manufacturer A charger that is suitable for one type of battery pack may create a risk of fire when used with another battery pack 2 Use power tools only with specifically desig nated battery packs Use of any other battery packs may create a risk of injury and fire 3 When battery pack is...

Page 5: ...s Position your body to either side of the blade but not in line with the blade Kickback could cause the saw to jump backwards but kickback forces can be controlled by the operator if proper precautions are taken 2 When blade is binding or when interrupting a cut for any reason release the trigger and hold the saw motionless in the material until the blade comes to a complete stop Never attempt to...

Page 6: ...g Leaving blade exposed is VERY DANGEROUS and can lead to serious personal injury Additional safety warnings 1 Use extra caution when cutting damp wood pressure treated lumber or wood containing knots Maintain smooth advancement of tool with out decrease in blade speed to avoid overheating the blade tips 2 Do not attempt to remove cut material when blade is moving Wait until blade stops before gra...

Page 7: ...orts e g by third parties forwarding agents special requirement on pack aging and labeling must be observed For preparation of the item being shipped consult ing an expert for hazardous material is required Please also observe possibly more detailed national regulations Tape or mask off open contacts and pack up the battery in such a manner that it cannot move around in the packaging 11 When dispo...

Page 8: ...the tool Doing so may cause a malfunction of the wireless unit 18 Do not remove the sticker on the wireless unit 19 Do not put any sticker on the wireless unit 20 Do not leave the wireless unit in a place where static electricity or electrical noise could be generated 21 Do not leave the wireless unit in a place sub ject to high heat such as a car sitting in the sun 22 Do not leave the wireless un...

Page 9: ...ed remove the batteries from the tool and charge the batteries Protections against other causes Protection system is also designed for other causes that could damage the tool and allows the tool to stop automatically Take all the following steps to clear the causes when the tool has been brought to a temporary halt or stop in operation 1 Turn the tool off and then turn it on again to restart 2 Cha...

Page 10: ...ening the lever For cleaner safer cuts set cut depth so that no more than one blade tooth projects below workpiece Using proper cut depth helps to reduce potential for danger ous KICKBACKS which can cause personal injury 1 Fig 10 1 Lever NOTICE If the base doesn t slide up or down smoothly the depth guide may have been tilted In this case adjust the depth guide refer the section about adjusting th...

Page 11: ...he lamp goes out 10 seconds after releasing the switch trigger 1 Fig 15 1 Lamp NOTE Use a dry cloth to wipe the dirt off the lens of the lamp Be careful not to scratch the lens of lamp or it may lower the illumination Electric brake This tool is equipped with an electric blade brake If the tool consistently fails to quickly stop the circular saw blade after switch lever release have tool serviced ...

Page 12: ...1 Clamping screw 2 Sub base Installing or removing circular saw blade CAUTION Be sure the circular saw blade is installed with teeth pointing up at the front of the tool CAUTION Use only the Makita wrench to install or remove the circular saw blade 1 Loosen the lever on the depth guide and move the base down 1 Fig 18 1 Lever 2 Install the inner flange ring country specific circular saw blade outer...

Page 13: ...that the correct side of protrusion on the inner flange faces outward and then place saw blade and outer flange 1 2 3 4 5 Fig 22 1 Mounting shaft 2 Inner flange 3 Circular saw blade 4 Outer flange 5 Hex bolt WARNING BE SURE TO TIGHTEN THE HEX BOLT CLOCKWISE SECURELY Also be careful not to tighten the bolt forcibly Slipping your hand from the hex wrench can cause a personal injury WARNING Make sure...

Page 14: ...1 2 3 Fig 25 1 Hose of the vacuum cleaner 2 Front cuff 24 3 Dust nozzle Adjusting angle of dust nozzle The angle of the dust nozzle can be adjusted by rotating the dust nozzle When operating the tool without connecting a vacuum cleaner bring the dust nozzle downward to prevent the operator from being exposed to sawdust When operating the tool with connecting a vacuum cleaner bring the dust nozzle ...

Page 15: ...is completed To get clean cuts keep your sawing line straight and your speed of advance uniform If the cut fails to prop erly follow your intended cut line do not attempt to turn or force the tool back to the cut line Doing so may bind the circular saw blade and lead to dangerous kickback and possible serious injury Release switch wait for cir cular saw blade to stop and then withdraw tool Realign...

Page 16: ...ard corresponds to the cutting edge 1 Fig 32 1 Adjusting screws When bevel cutting with the guide rail use the slide lever to prevent the tool from falling over Move the slide lever on the tool base in the direction of arrow so that it engages the undercut groove in the guide rail 1 Fig 33 1 Slide lever WIRELESS ACTIVATION FUNCTION What you can do with the wireless activation function The wireless...

Page 17: ... 3 Lid 4 Recessed portion When removing the wireless unit open the lid slowly The hooks on the back of the lid will lift the wireless unit as you pull up the lid 1 2 3 Fig 37 1 Wireless unit 2 Hook 3 Lid After removing the wireless unit keep it in the supplied case or a static free container NOTICE Always use the hooks on the back of the lid when removing the wireless unit If the hooks do not catc...

Page 18: ...vation button on the tool while the wireless acti vation lamp on the cleaner is blinking If the wireless activation lamp does not blink in green push the wire less activation button briefly and hold it down again NOTE When performing two or more tool registra tions for one vacuum cleaner finish the tool registra tion one by one Starting the wireless activation function NOTE Finish the tool registr...

Page 19: ...ction Description of the wireless activation lamp status 1 Fig 43 1 Wireless activation lamp The wireless activation lamp shows the status of the wireless activation function Refer to the table below for the meaning of the lamp status Status Wireless activation lamp Description Color On Blinking Duration Standby Blue 2 hours The wireless activation of the vacuum cleaner is available The lamp will ...

Page 20: ...n become red After that press the wireless activation button on the tool in the same way 1 2 1 Fig 38 1 2 1 2 Fig 45 1 Wireless activation button 2 Wireless activation lamp If the cancellation is performed successfully the wire less activation lamps will light up in red for 2 seconds and start blinking in blue NOTE The wireless activation lamps finish blinking in red after 20 seconds elapsed Press...

Page 21: ... the power button on the vacuum cleaner is turned on Push the wireless activation button briefly and perform the tool registration cancellation procedures again The tool registration procedures for the tool or vacuum cleaner have not finished Perform the tool registration procedures for both the tool and the vacuum cleaner at the same timing Radio disturbance by other appliances which generate hig...

Page 22: ...mation or cracks may result To maintain product SAFETY and RELIABILITY repairs any other maintenance or adjustment should be performed by Makita Authorized or Factory Service Centers always using Makita replacement parts Adjusting 0 cut or 45 cut accuracy NOTICE Do not engage the levers for 1 bevel angle when adjusting 0 cut accuracy NOTICE Do not engage the positive stopper for 22 5 or 60 bevel a...

Page 23: ...ctory But if it is off you can adjust it as the following procedure 1 Set the tool to the maximum cutting depth 2 Make sure all levers and screws are tightened 3 Loosen the screws shown in the figure 4 While opening the lower guard move the rear of the base so that the distance A and B becomes equal 1 1 2 A B Fig 50 1 Screw 2 Base 5 Tighten the screws and make a test cut to check the parallelism O...

Page 24: ...www makita com Makita Europe N V Makita Corporation 3 11 8 Sumiyoshi cho Anjo Aichi 446 8502 Japan Jan Baptist Vinkstraat 2 3070 Kortenberg Belgium 885938 224 EN 20211005 ...

Reviews: