background image

4 ENGLISH

WARNING:

 

The vibration emission during 

actual use of the power tool can differ from the 

declared value(s) depending on the ways in which 

the tool is used especially what kind of workpiece 

is processed.

WARNING:

 

Be sure to identify safety mea-

sures to protect the operator that are based on an 

estimation of exposure in the actual conditions of 

use (taking account of all parts of the operating 

cycle such as the times when the tool is switched 

off and when it is running idle in addition to the 

trigger time).

EC Declaration of Conformity

For European countries only

The EC declaration of conformity is included as Annex A 

to this instruction manual.

SAFETY WARNINGS

General power tool safety warnings

WARNING:

 

Read all safety warnings, instruc-

tions, illustrations and specifications provided 

with this power tool.

 Failure to follow all instructions 

listed below may result in electric shock, fire and/or 

serious injury.

Save all warnings and instruc-

tions for future reference.

The term "power tool" in the warnings refers to your 

mains-operated (corded) power tool or battery-operated 

(cordless) power tool.

Work area safety

1. 

Keep work area clean and well lit.

 Cluttered or 

dark areas invite accidents.

2. 

Do not operate power tools in explosive atmo-

spheres, such as in the presence of flammable 

liquids, gases or dust.

 Power tools create sparks 

which may ignite the dust or fumes.

3. 

Keep children and bystanders away while 

operating a power tool.

 Distractions can cause 

you to lose control.

Electrical safety

1. 

Power tool plugs must match the outlet. Never 

modify the plug in any way. Do not use any 

adapter plugs with earthed (grounded) power 

tools. 

Unmodified plugs and matching outlets will 

reduce risk of electric shock.

2. 

Avoid body contact with earthed or grounded 

surfaces, such as pipes, radiators, ranges and 

refrigerators.

 There is an increased risk of elec-

tric shock if your body is earthed or grounded.

3. 

Do not expose power tools to rain or wet con-

ditions.

 Water entering a power tool will increase 

the risk of electric shock.

4. 

Do not abuse the cord. Never use the cord for 

carrying, pulling or unplugging the power tool. 

Keep cord away from heat, oil, sharp edges 

or moving parts.

 Damaged or entangled cords 

increase the risk of electric shock.

5. 

When operating a power tool outdoors, use an 

extension cord suitable for outdoor use.

 Use of 

a cord suitable for outdoor use reduces the risk of 

electric shock.

6. 

If operating a power tool in a damp location 

is unavoidable, use a residual current device 

(RCD) protected supply.

 Use of an RCD reduces 

the risk of electric shock.

7. 

Power tools can produce electromagnetic 

fields (EMF) that are not harmful to the user.

 

However, users of pacemakers and other similar 

medical devices should contact the maker of their 

device and/or doctor for advice before operating 

this power tool.

Personal safety

1. 

Stay alert, watch what you are doing and use 

common sense when operating a power tool. 

Do not use a power tool while you are tired or 

under the influence of drugs, alcohol or med

-

ication.

 A moment of inattention while operating 

power tools may result in serious personal injury.

2. 

Use personal protective equipment. Always 

wear eye protection.

 Protective equipment such 

as a dust mask, non-skid safety shoes, hard hat or 

hearing protection used for appropriate conditions 

will reduce personal injuries.

3. 

Prevent unintentional starting. Ensure the 

switch is in the off-position before connecting 

to power source and/or battery pack, picking 

up or carrying the tool.

 Carrying power tools with 

your finger on the switch or energising power tools 

that have the switch on invites accidents.

4. 

Remove any adjusting key or wrench before 

turning the power tool on.

 A wrench or a key left 

attached to a rotating part of the power tool may 

result in personal injury.

5. 

Do not overreach. Keep proper footing and 

balance at all times.

 This enables better control 

of the power tool in unexpected situations.

6. 

Dress properly. Do not wear loose clothing or 

jewellery. Keep your hair and clothing away 

from moving parts.

 Loose clothes, jewellery or 

long hair can be caught in moving parts.

7. 

If devices are provided for the connection of 

dust extraction and collection facilities, ensure 

these are connected and properly used.

 Use of 

dust collection can reduce dust-related hazards.

8. 

Do not let familiarity gained from frequent use 

of tools allow you to become complacent and 

ignore tool safety principles.

 A careless action 

can cause severe injury within a fraction of a 

second.

9. 

Always wear protective goggles to protect 

your eyes from injury when using power tools. 

The goggles must comply with ANSI Z87.1 in 

the USA, EN 166 in Europe, or AS/NZS 1336 

in Australia/New Zealand. In Australia/New 

Zealand, it is legally required to wear a face 

shield to protect your face, too.

Summary of Contents for HR004GZ

Page 1: ...INSTRUCTION MANUAL Cordless Combination Hammer HR001G HR002G HR003G HR004G ENGLISH Original instructions Read before use ...

Page 2: ...epending on your region of residence WARNING Only use the battery cartridges and chargers listed above Use of any other battery cartridges and chargers may cause injury and or fire Symbols The followings show the symbols used for the equip ment Be sure that you understand their meaning before use Read instruction manual Ni MH Li ion Only for EU countries Do not dispose of electric equipment or bat...

Page 3: ...ccording to applicable standard Model HR001G Work mode Vibration emission Uncertainty K Applicable standard Hammer drilling into concrete ah HD 7 0 m s 2 1 5 m s 2 EN60745 2 6 Hammer drilling into concrete with DX12 ah HD 7 0 m s2 1 5 m s 2 EN60745 2 6 Chiselling function with side grip ah Cheq 6 5 m s 2 1 5 m s 2 EN60745 2 6 Drilling into metal ah D 2 5 m s 2 or less 1 5 m s 2 EN60745 2 1 Model H...

Page 4: ...n extension cord suitable for outdoor use Use of a cord suitable for outdoor use reduces the risk of electric shock 6 If operating a power tool in a damp location is unavoidable use a residual current device RCD protected supply Use of an RCD reduces the risk of electric shock 7 Power tools can produce electromagnetic fields EMF that are not harmful to the user However users of pacemakers and othe...

Page 5: ...r one type of battery pack may create a risk of fire when used with another battery pack 2 Use power tools only with specifically desig nated battery packs Use of any other battery packs may create a risk of injury and fire 3 When battery pack is not in use keep it away from other metal objects like paper clips coins keys nails screws or other small metal objects that can make a connection from on...

Page 6: ...esult in loss of your eyesight 5 Do not short the battery cartridge 1 Do not touch the terminals with any con ductive material 2 Avoid storing battery cartridge in a con tainer with other metal objects such as nails coins etc 3 Do not expose battery cartridge to water or rain A battery short can cause a large current flow overheating possible burns and even a breakdown 6 Do not store the tool and ...

Page 7: ... 10 The wireless unit is an accurate instrument Be careful not to drop or strike the wireless unit 11 Avoid touching the terminal of the wireless unit with bare hands or metallic materials 12 Always remove the battery on the product when installing the wireless unit into it 13 When opening the lid of the slot avoid the place where dust and water may come into the slot Always keep the inlet of the ...

Page 8: ...en If not it may accidentally fall out of the tool causing injury to you or someone around you CAUTION Do not install the battery cartridge forcibly If the cartridge does not slide in easily it is not being inserted correctly Indicating the remaining battery capacity Press the check button on the battery cartridge to indi cate the remaining battery capacity The indicator lamps light up for a few s...

Page 9: ... not turn the adjusting dial when the tool is running Failure to do so may result in the loss of control of the tool and cause an injury NOTICE If the tool is operated continuously at low speed for a long time the motor will get over loaded resulting in tool malfunction NOTICE The speed adjusting dial can be turned only as far as 5 and back to 1 Do not force it past 5 or 1 or the speed adjusting f...

Page 10: ...the neutral posi tion the switch trigger cannot be pulled Changing the quick change chuck for SDS plus For HR002G HR004G The quick change chuck for SDS plus can be easily exchanged for the quick change drill chuck Removing the quick change chuck for SDS plus CAUTION Before removing the quick change chuck for SDS plus be sure to remove the bit Grasp the change cover of the quick change chuck for SD...

Page 11: ...ng knob Rotation only For drilling in wood metal or plastic materials rotate the action mode changing knob to the symbol Use a twist drill bit or wood drill bit 1 1 Rotation only Hammering only For chipping scaling or demolition operations rotate the action mode changing knob to the symbol Use a bull point cold chisel scaling chisel etc 1 1 Hammering only Hook CAUTION Always remove the battery whe...

Page 12: ... tool drop from the hook and result in personal injury The hook is also used for connecting the lanyard tether strap Be sure to connect the lanyard tether strap to the double looped portion of the hook 1 2 3 1 Double looped portion of the hook 2 Lanyard tether strap 3 Locking carabiner multi action and screw gate type Adjusting the nozzle position of the dust collection system Optional accessory P...

Page 13: ...era tion during operation the motor is forcibly stopped to reduce the burden on the wrist NOTE This function does not work if the acceleration does not reach the predetermined one when the tool is swung NOTE If the bit is swung at the predetermined acceleration during chipping scaling or demolishing the motor is forcibly stopped In this case release the switch trigger and then pull the switch trig...

Page 14: ...e chisel angle rotate the action mode chang ing knob to the O symbol Turn the chisel to the desired angle 1 1 Action mode changing knob Rotate the action mode changing knob to the sym bol Then make sure that the chisel is securely held in place by turning it slightly Depth gauge The depth gauge is convenient for drilling holes of uniform depth Press and hold the lock button and then insert the dep...

Page 15: ...tool and on yourself when performing overhead drilling operations Attach the dust cup to the bit as shown in the figure The size of bits which the dust cup can be attached to is as follows Model Bit diameter Dust cup 5 6 mm 14 5 mm Dust cup 9 12 mm 16 mm 1 1 Dust cup Dust cup set Optional accessory Before installing the dust cup set remove the bit from the tool if installed Install the dust cup se...

Page 16: ...llection system for core drilling or chiseling NOTICE Do not use the dust collection system for drilling in wet concrete or use this system in wet environment Failure to do so may cause malfunction NOTE If the battery cartridge is in low temperature the tool s capability may not be fully obtained In this case warm up the battery cartridge by using the tool with no load for a while to fully obtain ...

Page 17: ... will come off when reversing the tool NOTICE Pressing excessively on the tool will not speed up the drilling In fact this excessive pressure will only serve to damage the tip of your drill bit decrease the tool performance and shorten the service life of the tool Set the action mode changing knob to the symbol For HR001G HR003G Optional accessory Attach the chuck adapter to a keyless drill chuck ...

Page 18: ...t Optional accessory CAUTION Always be sure that the tool is switched off and the battery cartridge is removed before carrying out any work on the tool CAUTION Be sure to wear dust mask when disposing of dust CAUTION Empty the dust case regularly before the dust case becomes full Failure to do so may decrease the dust collection performance and cause dust inhalation CAUTION The performance of dust...

Page 19: ...6 Do not wrap lanyards around or allow them to come in contact with sharp or rough edges 7 Fasten the other end of the lanyard outside the working area so that a falling tool is held securely 8 Attach the lanyard so that the tool will move away from the operator if it falls Dropped tools will swing on the lanyard which could cause injury or loss of balance 9 Do not use near moving parts or running...

Page 20: ...e wireless unit align the projections with the recessed portions on the slot 3 1 4 2 1 Wireless unit 2 Projection 3 Lid 4 Recessed portion When removing the wireless unit open the lid slowly The hooks on the back of the lid will lift the wireless unit as you pull up the lid 1 2 3 1 Wireless unit 2 Hook 3 Lid After removing the wireless unit keep it in the supplied case or a static free container N...

Page 21: ... button on the tool while the wireless acti vation lamp on the cleaner is blinking If the wireless activation lamp does not blink in green push the wire less activation button briefly and hold it down again NOTE When performing two or more tool registra tions for one vacuum cleaner finish the tool registra tion one by one Starting the wireless activation function NOTE Finish the tool registration ...

Page 22: ...eless activation function Description of the wireless activation lamp status 1 1 Wireless activation lamp The wireless activation lamp shows the status of the wireless activation function Refer to the table below for the meaning of the lamp status Status Wireless activation lamp Description Color On Blinking Duration Standby Blue 2 hours The wireless activation of the vacuum cleaner is available T...

Page 23: ...nd then become red After that press the wireless activation button on the tool in the same way 1 2 1 2 1 Wireless activation button 2 Wireless activation lamp If the cancellation is performed successfully the wire less activation lamps will light up in red for 2 seconds and start blinking in blue NOTE The wireless activation lamps finish blinking in red after 20 seconds elapsed Press the wireless ...

Page 24: ... power button on the vacuum cleaner is turned on Push the wireless activation button briefly and perform the tool registration cancellation procedures again The tool registration procedures for the tool or vacuum cleaner have not finished Perform the tool registration procedures for both the tool and the vacuum cleaner at the same timing Radio disturbance by other appliances which generate high in...

Page 25: ...1 Remove the dust case while pressing down the lever of the dust case 1 1 Lever 2 Insert the flat blade screwdriver into the slots of the filter cover to remove the filter cover 2 1 1 Flat blade screwdriver 2 Filter cover 3 Remove the filter from the filter case 1 2 1 Filter 2 Filter case 4 Attach a new filter to the filter case and then attach the filter cover 5 Close the cover of the dust case a...

Page 26: ...ur local Makita Service Center Carbide tipped drill bits SDS Plus carbide tipped bits Core bit Bull point Diamond core bit Cold chisel Scaling chisel Grooving chisel Chuck adapter Keyless drill chuck Bit grease Depth gauge Blow out bulb Dust cup Dust cup set Hook set Dust case set Drill chuck set Filter set Tool holder set Joint set Dust collection system Wireless unit Makita genuine battery and c...

Page 27: ...27 ...

Page 28: ...www makita com Makita Europe N V Makita Corporation 3 11 8 Sumiyoshi cho Anjo Aichi 446 8502 Japan Jan Baptist Vinkstraat 2 3070 Kortenberg Belgium 885753A226 EN 20190827 ...