P 10/10
W
iring diagram
[2] Handle (cont.)
Route Field lead wires as described below in Fig. D-5.
Fig. D-5
Terminal block
(h)
(g)
(a, b, c, d)
[1] When connecting Lead wire (c) to No.4 Terminal of Switch,
insert it from the direction shown in the figure on right.
[2] Before setting Switch in place, fix the following Lead wires
with Lead wire holders under Switch:
(b), (d), (h)
[3] Put Insulated connector in this portion.
[4] Fix the following Lead wires with this Lead wire holder:
(a), (b), (c), (d)
[5] Fix the following Lead wires with this Lead wire holder:
(g), (h)
[6] Route the following Lead wires between the inside wall
of Handle and the rib for fixing Controller:
(e), (f); (g), (h)
[7] Put Noise suppressor in this portion if used.
Handle
GA5021C/ GA6021C
(k)
(e, f)
Lead wires of Controller:
(a) White, to Insulated connector
(b) Black, to No.3 Terminal of Switch
(c) Red or Purple or Blue,
to No.4 Terminal of Switch
(d) Orange, to No.2 Terminal of Switch
(e) Black, to Pickup coil
(f) White, to Pickup coil
Field lead wires:
(g) White, to Insulated connector
(h) Orange, to No.2 Terminal of Switch
Lead wires of Noise suppressor (if used):
(i) White, to Controller
(j) Black, to Controller
Relay wire:
(k) Black, from No.3 Terminal of Switch to Terminal block
Index of Lead wire
Insulated
connector
[4]
[3]
Switch
Contr
oller
(i, j)
Noise suppressor
(if used)
[5]
[6]
[6]
[7]
rib for fixing
Controller
[1]
No.4 Terminal
(c)
Lead wire holders
(h)
(b), (d)
[2]