61 / 71
4-5-14
Connecting Control cable to Blower body (for Model EB5300TH)
Fig. 145
1
Pass the barrel nipple of Control cable through Adjust
screw [1]. Then turn Throttle [2] clockwise and hold it
with finger, and then attach the barrel nipple to Swivel
[3].
Tips
Note the orientation of Swivel [3]. If it is oriented wrong,
the barrel nipple cannot be attached.
Fig. 146
2
Connect two Straight terminals [1] of Lead unit with
those from Ignition coil and Earth terminal, and then put
the terminals and Corrugated tube [2] in the space of
Front volute case [3].
Tips
Position Corrugated tube [2] so that the end face of
the tube is aligned with the marking (indicated by the
red dotted line) on Front volute case.
Be careful not to twist the cable.
Fig. 147
3
Fix Control cable [3] in Clamp (2 pcs) [2] by tightening
4x14 Tapping screw [1].
Fig. 148
4
By tightening two M5x16 Hex socket head bolts [1],
fasten Fuel tank [2] to Frame.
[2]
[1]
[1]
[2]
[3]
[1]
[2]
[3]
[1]
[2]
[3]