2 ENGLISH
SPECIFICATIONS
Model:
DUR194
Type of handle
Loop handle
No load speed
2: 6,000 min
-1
1: 4,500 min
-1
Overall length
(without cutting tool)
1,580 mm
Nylon cord diameter
2.0 mm
Applicable cutting tool and
cutting diameter
8-tooth blade
(P/N 191Y44-2)
200 mm
Nylon cutting head
(P/N 198893-8, 191D89-4)
280 mm
Plastic blade
(P/N 191Y45-0)
230 mm
Rated voltage
D.C. 18 V
Net weight
2.6 - 2.9 kg
•
Due to our continuing program of research and development, the specifications herein are subject to change
without notice.
•
Specifications may differ from country to country.
•
The weight may differ depending on the attachment(s), including the battery cartridge. The lightest and heavi
-
est combination, according to EPTA-Procedure 01/2014, are shown in the table.
Applicable battery cartridge and charger
Battery cartridge
BL1815N / BL1820B / BL1830B / BL1840B / BL1850B / BL1860B
Charger
DC18RC / DC18RD / DC18RE / DC18SD / DC18SE / DC18SF /
DC18SH / DC18WC
•
Some of the battery cartridges and chargers listed above may not be available depending on your region of residence.
WARNING:
Only use the battery cartridges and chargers listed above.
Use of any other battery cartridges
and chargers may cause injury and/or fire.
Recommended cord connected power source
Portable power pack
PDC01
•
The cord connected power source(s) listed above may not be available depending on your region of residence.
•
Before using the cord connected power source, read instruction and cautionary markings on them.
Noise
Cutting tool
Sound pressure level (L
pA
)
dB(A)
Sound power level (L
WA
)
dB(A)
Applicable
standard
L
pA
dB(A)
Uncer-
tainty (K)
dB(A)
L
WA
dB(A)
Uncer-
tainty (K)
dB(A)
8-tooth blade
73.5
2.9
88.6
2.9
ISO22868
(ISO11806-1)
Nylon cutting head
72.6
2.6
85.3
3.0
ISO22868
(ISO11806-1)/
EN50636-2-91
Plastic blade
75.8
0.7
86.2
2.5
ISO22868
(ISO11806-1)/
EN50636-2-91
•
Even if the sound pressure level listed above is 80 dB (A) or less, the level under working may exceed 80 dB
(A). Wear ear protection.
NOTE:
The declared noise emission value(s) has been measured in accordance with a standard test method and
may be used for comparing one tool with another.
NOTE:
The declared noise emission value(s) may also be used in a preliminary assessment of exposure.