background image

R

epair

C

omparison of products

P 3 / 4 

Specifications

Model No.

Chargeable battery voltage

* Charging 
         time : min.

Dimensions 
          : mm ( " )

Length

Width

Height

Net weight : Kg (lbs)

MAKITA

DC1413

DC1411

7.2V - 14.4V

7.2V - 14.4V

1.3Ah

1.7Ah

2.0Ah

2.2Ah

2.6Ah

3.0Ah

Approx. 30 min.

Approx. 40 min.

Approx. 50 min.

Approx. 60 min.

Approx. 70 min.

Approx. 45 min.

Approx. 40 min.

Approx. 50 min.

Approx. 65 min.

Approx. 75 min.

Approx. 90 min.

Approx. 60 min.

193  (7-5/8)

92 (3-5/8)

78 (3-1/16)

0.41  (0.9)

<Note> The charging time can be different from conditions to conditions of batteries and room temperature.

<1> The circuit board can not be repaired, because the circuit itself are molded on the board .
       It has to be replaced as a set with new one.
<2> In case of damaged varistor or fuse, they can be repaired according to the following procedure without 
        replacing the circuit board.

(1) How to find broken varistor
  a. In case that the surface of varistor (ref. to the following illustration) has broken or has become black, and 
      fuse has been cut, the varistor has been damaged.
  b. Varistor can be damaged easily, if the charger is plugged in a double voltage of the rating one.
  c. It is considered that the varistor has been broken for other reasons, if the fuse is broken while the surface
     of  varistor is not damaged. In this case circuit board has to be replaced.

Fuse

Varistor

Circuit board

Charger case set

Summary of Contents for DC1413

Page 1: ...60 60 60 60 Output voltage V Output current A Charging time minute Ni Cd battery of 1 3Ah Ni Cd battery of 2 0Ah Ni MH battery of 2 6Ah Ni MH battery of 3 0Ah 7 2 9 6 12 14 4 2 6 Approx 30 Approx 45 Approx 60 Approx 70 Protection of circuit from over current by Fuse Both of Ni Cd and Ni MH batteries from 7 2V to 14 4V can be charged with DC1413 LG125 in shorter time comparing with the existing cha...

Page 2: ...he charging process in 150 minutes after starting the charge if the full charged condition would not be perceiving with any of the above 3 systems Battery s voltage and temperature Charging time Full charged line 1 2 3 Minus delta V system Delta T system T system 1 Battery s voltage 2 Heated battery s temperature It can not be charged completely 3 Battery s normal temperature in charging process T...

Page 3: ...oard can not be repaired because the circuit itself are molded on the board It has to be replaced as a set with new one 2 In case of damaged varistor or fuse they can be repaired according to the following procedure without replacing the circuit board 1 How to find broken varistor a In case that the surface of varistor ref to the following illustration has broken or has become black and fuse has b...

Page 4: ...ing iron b Assemble new fuse to the circuit board by soldering c Cut the surplus of fuse s wire with nipper b Assemble new varistor to the circuit board by soldering c Cut the surplus of varistor s wire with nipper Varistor Circuit board When removing varistor melt this part with soldering iron and remove varistor Varistor Circuit board Less than 3mm Fig 2 Fig 3 Fig 4 Fuse When removing fuse melt ...