(3) How to Check the Pre-set Number of Blows  

(5) Relation Between Preset Number of Blows and Time Required to Finish the Blows

(4) Relation Between Pre-set Number of Blows and its function

Release the switch trigger, install the battery on the machine, and then check how many times the green or the red
light of the LED blinks.
As mentioned in page I-3, the green light blinking indicates the second digit of the pre-set number of blows,
and the red light blinking indicates the first digit.
Therefore, when the pre-set number of blows is 12, you can see the following states on the LED:
    First, the green light blinks once.
    Second, the red light blinks twice.
    Third, the lights turn off.

The equation for this relation is:
Time required = ( Preset number of hammer blows X *2 ) X **20ms

       Note*  : "X2" means two blows per spindle rotation.   
                     Consequently, when the preset number of hammer-blows is 10, the hammer actually blows 20 times.
       Note**: ms = micro second

The following graph shows this relation.

Preset number of hammer-blows

T

ime r

equir

ed (sec.)

0

10

20

30

40

50

60

70

80

90

100

0

0.5

1

1.5

2

2.5

3

3.5

4

Automatic Blow-Stop System does not
work.

Automatic Blow-Stop System does not
work.

Automatic Blow-Stop System does not
work.

When you keep on pulling the trigger until
the blow action finish the pre-set number of
blows, the green light turns on to notify you
that the bolt has been completely tightened.

On Forward Rotation

On Reverse Rotation

Pre-set number
of blows

Forward or

Reverse

00

01 to 99

When you release the trigger before
the blow action finish the pre-set number of
blows, the red light turns on to notify you
that the bolt has been poorly tightened.

Summary of Contents for BTD042

Page 1: ...3 8 version of the existing model BTW062 Of course it is equipped with Automatic Blow Stop System and indication lamp showing complete and incomplete fastening like as BTD042 and BTD062 BTW072 BTD042...

Page 2: ...otector optional accessory can be installed for protecting work piece from the accidental scratch Rubber protector Easily operatable variable speed control switch Battery power warning lamp on B90117A...

Page 3: ...blowing time Note The required fastening torque N m can not be set with this system Push button type reverse switch Light and compact body Model No BTD072 BTD072 Overall length Net weight 162mm 1 09...

Page 4: ...he lights blink ten times they come to be on continuously 2 Softly hit the foot of the machine only once with a driver etc The lights turn off The lights turn off Fig 1 4 While pulling the switch trig...

Page 5: ...required Preset number of hammer blows X 2 X 20ms Note X2 means two blows per spindle rotation Consequently when the preset number of hammer blows is 10 the hammer actually blows 20 times Note ms micr...

Page 6: ...D062 BTW072 When Fastening High Tensile Bolt M6 When Fastening Standard Bolt M8 When Fastening High Tensile Bolt M8 Torque N m in lbs Torque N m in lbs Torque N m in lbs Time sec 0 0 0 25 20 10 15 5 0...

Page 7: ...ousing R and L Remove hammer case from housing by taking off 4 pan head screws M4x20 and disassemble housing R and L as illustrated in Fig 1 Fig 1 Pan head screws M4x20 Hammer case Housing 2 Disassemb...

Page 8: ...Spindle Cam groove top of spindle Opening for steel ball inserting Steel ball 4 8 x 2pcs BTD042 Steel ball 5 6 x 2pcs BTD062 BTW072 Steel ball 3 x 29 pcs Hammer 1R045 Large gear extractor L L 85mm L...

Page 9: ...ll bearing 6801LLB Internal gear case Fig 6 6 Fastening FET spacer with tapping screw ST 3x8 When assembling FET spacer the fastening torque of tapping screw ST 3x8 is approx 1 1 Nm 1 5 Nm 11Kgf cm 15...