6
ASSEMBLY
CAUTION:
•
Always disconnect the air hose before loading the
nailer.
Loading the nailer
CAUTION:
•
Make sure that the coil support plate is set to the
correct step for used nails.
1
2
013444
Disconnect the air hose from the tool. Select nails
suitable for your work. Depress the latch lever and open
the door and magazine cap.
1
2
3
013445
Turn the adjust shaft so that the arrow with nail size
indicated on the change plate will point to the
corresponding graduation increment marked on the
magazine. If the tool is operated with the change plate
set to the wrong step, poor nail feed or malfunction of
the tool may result.
1
2
3
013446
Place the nail coil over the change plate. Uncoil enough
nails to reach the nail guide. Place the first nail in the
feeder and the second nail in the feed claw. Place other
uncoiled nails on feeder body. After checking to see that
the nail coil is set properly in the magazine, close the
magazine cap slowly and then close the door until it locks.
Connecting air hose
Slip the air socket of the air hose onto the air fitting on
the nailer. Be sure that the air socket locks firmly into
position when installed onto the air fitting. A hose
coupling must be installed on or near the tool in such a
way that the pressure reservoir will discharge at the
time the air supply coupling is disconnected.
Changing the trigger for intermittent nailing
CAUTION:
•
Always disconnect the air hose and unload the
tool with nails before replacing the trigger.
•
After the trigger replacement, always check the
tool operates properly before actual work. Do not
load the tool with any nails before checking the
function to avoid unexpected nailing.
1
2
3
4
013502
The trigger for continuous nailing is factory-installed. To
change the nailing mode to intermittent nailing, replace
the switch trigger with the one for intermittent nailing.
1
2
3
013551
1.
Turn the lock lever to the "LOCK" position.
2. Push the pin securing the trigger from the
urethane washer side, and then remove the
urethane washer by fingers or flathead
screwdriver and so on. Pull the pin and remove it
from the hole in the housing.
3.
Set the trigger assembly for intermittent nailing. Turn
the hinged part inward the trigger, and then set the
part to contact the rod of the valve in the housing.
4.
Insert the pin to the hole and then secure it by
urethane washer.
5.
Connect the air hose, and then check whether the
tool operates properly. Refer to the section
“Changing intermittent nailing mode”.
1. Urethane
washer
2. Pin
3. Lock lever
1. Trigger for
continuous
nailing
2. Silver part
3. Trigger for
intermittent
nailing
4. Black part
1. Door
2. Feed Claw
3. Driver channel
1. Adjust shaft
2. Arrow
3. Change plate
1. Latch lever
2. Door
Summary of Contents for AN930H
Page 31: ...31 ...