PRODUCT INFORMATION 

 

SAFETY INFORMATION 

 

 

WARNING

 

Read this manual 

thoroughly

 before operating your 

generator. Failure to follow instructions could result in 
serious injury or death 

 

 

WARNING

 

MAKINEX GEN-6PGenerator designed for 
professional operators only, instruct operators in care 
and use of the machine before use! 

 

 

DANGER

 

 

GENERAL SAFETY PRECAUTIONS 

 

 

 

ALWAYS 

use in a well-ventilated area. 

 

ALWAYS 

ensure the applied load does not exceed the generators rating. 

Overloading the generator is dangerous and could cause serious damage. 

 

ALWAYS 

disconnect the generator when carrying out any maintenance. 

 

ALWAYS 

ensure the generator reaches operating speed before connecting 

a load. 

 

ALWAYS 

start the engine BEFORE connecting any appliances to the output 

receptacles. 

 

ALWAYS 

check the generator for damage before use. 

 

ALWAYS 

keep well clear of all moving parts on the generator at all times. 

 

NEVER 

allow children or animals near the generator. 

 

NEVER 

connect to a commercial or mains power supply, or any other 

electrical source. 

 

NEVER 

allow the generator to run out of fuel when a load is connected. 

 

NEVER 

alter or tamper with the internal wiring of the generator. 

 

NEVER 

climb or stand on the generator as dents may cause overheating of 

the acoustic lining. 

 

NEVER 

touch any part of the engine, alternator or exhaust when the 

generator is in use as these get hot and could burn. 

Summary of Contents for GEN-6P

Page 1: ...6KVa Generator GEN 6P 2 x 15A OUTLET OPERATOR S MANUAL...

Page 2: ...ATIONS 9 OVERALL MACHINE DIMENSIONS 10 FEATURES 10 OPERATION 11 BEFORE USE 11 OPERATING GENERATOR 13 STARTING THE ENGINE 13 CONNECTING ELECTRICAL DEVICES 13 SHUTTING DOWN THE GENERATOR 13 MAINTENANCE...

Page 3: ...rt of this publication may be reproduced in any form or by any means electronic or mechanical including photocopying without express written permission from MAKINEX Any type of reproduction or distrib...

Page 4: ...that should be paid careful attention CAUTION CAUTION indicates a potential hazardous situation which if not avoided may result in minor or moderate injury WARNING WARNING indicates a potentially haz...

Page 5: ...out any maintenance ALWAYS ensure the generator reaches operating speed before connecting a load ALWAYS start the engine BEFORE connecting any appliances to the output receptacles ALWAYS check the ge...

Page 6: ...spill Any spillage must be wiped clean and the generator allowed to dry before attempting to start the engine DANGER RISK OF BREATHING Running engine gives off Carbon Monoxide an odourless colourless...

Page 7: ...generator Keep children away from the generator at all times They may not be able to recognise the hazards of this product WARNING POSITIONING THE GENERATOR FOR USE ALWAYS leave at least a 1 metre gap...

Page 8: ...Page 8 of 22 SAFETY DECAL...

Page 9: ...UTPUT 3900W SOCKETS 2 X 15A SINGLE PHASE SOCKETS WITH RCBO PROTECTION WEIGHT 74 kg NOISE LEVEL 7M NO LOAD 70dB 50 LOAD 72dB 100 LOAD 74dB RATED POWER FACTOR 0 8 ENGINE TYPE SINGLE CYLINDER AIR COOLED...

Page 10: ...S FEATURES Durable Galvanised frame Multi cushion isolators for vibration reduction Compact design for easy storage and transport Lifting point for transportation RFL permanent magnet alternator OVERA...

Page 11: ...can damage it and shorten its life DO NOT attempt to start the engine before it has been properly serviced with the recommended oil This may result in an engine failure Adding Fuel WARNING FAILURE TO...

Page 12: ...g fuel cap 2 2 Loosen fuel cap slowly to release pressure 2 2 Slowly add unleaded gasoline to fuel tank DO NOT fill fuel above baffle This allows appropriate space for fuel expansion 2 3 Wait for spil...

Page 13: ...r until it is in the fully open position CONNECTING ELECTRICAL DEVICES The generator can supply 230V AC through 2 x 15amp sockets Before connecting any devices uncoil the earth stake and push firmly i...

Page 14: ...subjected to operator abuse or negligence To receive full value from the warranty the operator must maintain the generator as instructed in this manual and in the engine manual including proper stora...

Page 15: ...ING Fuel and fuel vapour are extremely flammable and explosive Fire or explosion from misuse of fuel can cause severe burns and even death To protect against rust formation during storage oil the cyli...

Page 16: ...erator to be free from defects in material and workmanship under normal domestic and industrial use and service for the period specified below conditional to the limitations and exclusions printed on...

Page 17: ...warranty excludes Cosmetic defects such as paint decals etc Wear items such as filter elements Pistons O rings etc Accessory parts such as starting batteries and storage covers Failures due to acts o...

Page 18: ...ivered within Australian territory USA units will be delivered within USA territory and European units will be delivered within its designated country s territories Where the specific warranty compone...

Page 19: ...Tel 407 446 1966 j spencer makinexusa com EUROPE Tel 31 0 6 24881203 31 0 6 50841849 SERVICE PART ORDERING For service and ordering parts please call AUS 1300 795 953 or 61 2 9460 8071 USA 407 446 19...

Page 20: ...Page 20 of 22 CONTACT INFORMATION AUSTRALIA NEW ZEALAND UNITED STATES OF AMERICA EUROPE W makinex com E sales makinex com...

Page 21: ...Page 21 of 22 APPENDICES APPENDIX A WIRING CIRCUIT DIAGRAM APPENDIX B RISK ASSESSMENT APPENDIX A WIRING CIRCUIT DIAGRAM...

Page 22: ...APPENDIX B RISK ASSESSMENT...

Reviews: