MAKELSAN UPS

1  BRIEF INTRODUCTION

1.1 Prolegomenon

The product is designed specially aiming at the requirement of MINI and MICRO

level computer with exquisite quality and excellent function, easy to operate. With the

development of customer office automatism and computerism, considering the bulk and

the position of positing space, the noise disturbance to personnel in office, the light,

thin, short and small product is our design direction, and we stress low noise. So this

product is optimum supply power partner for office and makes you can attain optimal

clean power quality.

1.2 Five design points

1. Small bulk and no occupation space

2. Light weight and convenience to transit

3. Beauty and nature, easy to install

4. Convenient to maintain and easy to operate

5. Package material with environment protection and no pollution to environment

1.3 Note

The manual makes you can operate and maintain the system easily. To normally exert

all functions of the system, please note the following:

1. Read the manual carefully before use

2. Perform the operation strictly according to operating process

3. Place the equipment carefully and lightly when moving the equipment

4. Install the power according to illumination in the manual

5. Please do not open the cover to avoid injury caused by electrical shock

6. Please charge batteries once every a period if no used for long time

7. Do not use UPS on the condition of overload to avoid UPS fault

8. Please carefully keep the manual for the future reference

9. Please handle the system according to "ABNORMITY HANDLING PROCESS" if

there presents any abnormal phenomenon in machine.

10. Please keep UPS neatness and cleanness

BRIEF INTRODUCTION

Summary of Contents for 1K

Page 1: ...ntain and easy to operate 5 Package material with environment protection and no pollution to environment 1 3 Note The manual makes you can operate and maintain the system easily To normally exert all...

Page 2: ...Welcome screen WELCOME TO 2 Display of system status _Pro AC IN BAT OK Note AC indicates utility BAT indicates battery AC IN indicates utility power is normal AC LOSS indicates utility power is abnorm...

Page 3: ...input frequency value INPUT FREQUENCY 50HZ 4 8 6 Display of output frequency value OUTPUT FREQUENCY 50HZ 5 8 7 Display of battery voltage value BATTERY VOLTAGE 220V 6 8 8 Display of output power perce...

Page 4: ...onvert to UPS inverter power output 20s later UPS pure AC output power is supplied by UPS internal power supply equipment 2 Turn off UPS inverter by pressing the OFF button UPS convert to utility bypa...

Page 5: ...terface receptacle Standard communication interface between UPS and computer 13 Power switch Power switch controls input output and battery power switch at the same time 14 Wiring terminal support Pow...

Page 6: ...ff before performing 2 Place lightly and carefully forbid to hit 3 Please do not move UPS inverted 3 2 Placement 1 Do not place the UPS on the slope or scraggy land Figure 4 2 Please place the UPS in...

Page 7: ...rain and damp place Figure 6 7 4 Please keep away from fire source and high temperature to avoid over high temperature Figure 8 5 Do not lay goods on the UPS Figure 9 6 Do not install UPS in the place...

Page 8: ...7 Running environment temperature INSTALLATION 4 INSTALLATION 4 1 Input 1 Prohibit using general household socket because the Max current of general socket is 15A the socket may be burned down becaus...

Page 9: ...ith screw driver Figure 12 2 Open the back panel and inspect the wiring terminal below the power switch Figure13 4 Relock the special cover after completing connection 5 Please first fetch in the powe...

Page 10: ...10 MAKELSANUPS INSTALLATION...

Page 11: ...11 MAKELSANUPS INSTALLATION...

Page 12: ...ize is as follows 9 The power cable and the impaction terminal must be first grade product manu factured by authentic manufacturer Prohibit use spent and inferior product 10 The power cable must be im...

Page 13: ...0V then connect L cable of UPS to the cable whose voltage measured is the highest means supply power of this phase is lighter than that of other two phase the N cable of UPS is con nected to utility n...

Page 14: ...current do not use over thin cable Please refer to Table 2 4 Avoid short circuit and overload 5 The comparison between output current rating and output cable size is listed in Table 2 Model Max input...

Page 15: ...ease ask professional personnel for handling immediately 7 User offers a good grounding system 8 Try to make the ground close to connecting point of grounding club or origination point in switch board...

Page 16: ...if there is any looseness retighten them if looseness 4 Do not connect load 5 Inspect if input voltage meet the demand of UPS 220V 10 with ammeter 5 2 Operation process for first start up After verif...

Page 17: ...t panel is lit on bypass indi cator is off and output indicator is lit on The welcome information is displayed on LCD output is UPS inverter powered 4 Shutdown input power of UPS utility indicator lig...

Page 18: ...mantle the unimportant load till the value displayed is less than 100 5 3 Operation process for routine turn off If you want to switch on off UPS when daily using please operate UPS according to the f...

Page 19: ...the right figure 1 UPS running status Utility is normal UPS runs normally and UPS is used under full load 2 Handling way needn t handling 6 2 UPS run status indication and handling ways when normal Pl...

Page 20: ...andling 3 panel indicator status is as the right figure 1 UPS running status Utilitysuppliespowerof220Vacnor mally and UPS runs normally 2 Handling way needn t handling 4 panel indicator status is as...

Page 21: ...PS panel 2 Handling way Please deal with it refer to status dealing flow Chart 20 6 panel indicator status is as the right figure 1 UPS running status Utility supplies power Under over load 125 overlo...

Page 22: ...ight figure 1 UPS running status Utility power is disconnected UPS is battery powered and load is full load Buzzer beeps once every four seconds The indicator of battery energy flashes every four seco...

Page 23: ...ease save files and close your computer 10 panel indicator status is as right figure 1 UPS running status Utility power may have been discon nected and battery power has been exhausted shutdown UPS au...

Page 24: ...rmonic noise in utility power is filtered by the filter on one hand utility power charges battery pack via the inverter and keeps battery power on full voltage level on the other hand utility power is...

Page 25: ...and the filter to avoid power disturbance to load 7 4UPS s running way when UPS runs on bypass mode There are five kinds of status when UPS runs on bypass mode 1 overload 2 inverter failure 3 when st...

Page 26: ...3 If you want to extend the time that the battery supplies power please ask the professional to increase the battery number and don t make bold to install the battery to avoid any danger 4 Please kee...

Page 27: ...TERFACE 8 Communication interface 8 1 The great mass of computer system have equipped UPS to avoid system failure and datum damage due to utility power fault you can monitor and control the power stat...

Page 28: ...h RS232 communication series port and computer The datum that UPS offers includes input voltage value output voltage value output frequency input frequency battery capacity percent used load percent U...

Page 29: ...ine wave Power factor 0 8 Distortion 3 linear load Battery Voltage 48VDC 192VDC Model Lead acid free from maintenance Offer time Refer to figure 27 Charging time 90 capacity after 8 10 hours Alarm Uti...

Page 30: ...o bypass and supplied power by utility Noise filter 10 100KHz at 40Db 100KHz 100KHz at 70dB LCD display Display input input voltage frequency battery voltage output power temperature Battery BVL One L...

Page 31: ...31 MAKELSANUPS Order Consent Number 1 UPS 1 2 UPS use manual 1 3 Intelligent monitoring software 1 4 Computer port cable 1 SHIPPINGLIST 10 Shipping list...

Page 32: ...32 MAKELSANUPS SHIPPINGLIST...

Page 33: ...33 MAKELSANUPS SHIPPINGLIST...

Page 34: ...34 MAKELSANUPS SHIPPINGLIST...

Page 35: ...RODUCTION 1 2 CONFIGURATION AND FUNCTION 2 3 PLACEMENT NOTES 6 4 INSTALLATION 8 5 OPERATION PROCESS 16 6 STATUS HANDLING 19 7 MOVEMENT HANDLING 24 8 COMMUNICATION INTERFACE 27 9 SPECIFICATION 29 10 SH...