background image

4B

6B

1A

4A

6A

2A 3A

1B 2B 3B

VCO SINE Shape and Amplitude

Trims for SINE shape (1A, 1B) and Amplitude (3A, 3B) are accessed through the top side of the module. 

Take care in lifting the top half of the module out of case for calibration.

1.Monitor the SINE (2A, 2B) from the VCO to be calibrated. If possible view the signal on an oscillo\

        scope and/ or spectrum analyzer as well. 

2. Set VCO to be calibrated near to frequency of C4. (4A, 4B)

3. Set oscilloscope for 2V/ div. by 2ms/ div. (skip to step 4. if no oscilloscope will be used).

4. Trim SINE Shape (1A, 1B) for least amount of audible harmonics (skip to step 5 if using oscilloscope).

5. If using an oscilloscope or spectrum analyzer adjust so the SINE shape is pure as possible, meaning    

        both the top and bottom arches are smooth, rounded and glitch free, and harmonics are minimized.

6. Amplitude is adjusted by trim 3A, 3B. Amplitude should be set using oscilloscope for measurement, to      

        roughly 10.5V peak to peak for VCO A and roughly 10.2V peak to peak for VCO B. There is some 

        cases where amplitude of VCO B will need to be greater or less than the above specification in order    

        for the, FM Bus and Fold circuits to operate correctly. See the last step of the VCO B FINAL OUT 

        Calibration for more details.

NOTE: Amplitude should not require adjustment in most cases.

Expect some small amount of harmonics in the SINE shape. Trim to satisfaction and then go make noise!

Summary of Contents for DPO

Page 1: ...DPO...

Page 2: ...defective products will be repaired or replaced at the option of Make Noise on a return to Make Noise basis with the customer paying the transit cost to Make Noise Please contact Make Noise for Return...

Page 3: ...nd 28HP of space in your euro rack synthesizer system confirm proper installation of included power cable on backside of module see picture below plug the 16 pin end power cable into the euro rack sty...

Page 4: ...nterrupt them completely by simply patching into the associated modulation destinations The DPO has two modulation buses each with multiple destinations the depth of which is adjustable per destinatio...

Page 5: ...avior Indicated by LED No LED Standard BLUE Phase LOCK to VCO B PINK Hard SYNC to VCO B AMBER Low Frequency Oscillator VCO B 1B Sine Waveform OUT 10Vpp 2B Square Waveform OUT 9Vpp Asymmetrical 3B FINA...

Page 6: ...CO B With nothing patched to FOLLOW CV IN works as standard panel control With Signal Patched to FOLLOW CV IN works as an attenuator for that signal 4 FM BUS INDEX unipolar panel control that sets the...

Page 7: ...ontrol signal input Normalled into the MOD BUS Range 8V 1C FOLD Panel Control unipolar control that continuously varies the low order harmonics of the signal by folding the waveform into itself 2C FOL...

Page 8: ...bad thing These errors manifest themselves in a looser interpretation of the ratio programmed making each note have subtle differences The BLUE LED indicates LOCK an extremely weak synchronization of...

Page 9: ...re or pulse shaped signal however just about any signal could be used with varying degrees of success The Duty Cycle width and Amplitude height of the signal will have some affect on the outcome FOLLO...

Page 10: ...ight sound like an odd collection of waveforms and functions but the selection is quite useful The SINE wave is the classic waveform that would feed a wave folder as utilized in both the Buchla 259 an...

Page 11: ...it dances atop the long wave cycles of the lower octaves Perfect for animating bass lines It also adds shimmer to the upper octaves especially when the rate of modulation is increased to the lower aud...

Page 12: ...n the fundamental VCO A also offers a unique SAW shape that is derived from the TRIANGLE core It is not the typical saw waveform as it has a stronger fundamental then is usually heard in a sawtooth sh...

Page 13: ...Output Tune the two oscillators to a simple interval such as unison a fifth or an octave Adjust FOLLOW panel control to about 3 00 Turn up VCO B Lin FM attenuator to 12 00 Turn FM BUS to 12 00 Send a...

Page 14: ...Calibrate the DPO while installed in the system in which it will be utilized 1 Monitor VCO B SINE 1B 2 Patch quantizer or MIDI to CV interface to 1V Octave INput 6 set FOLLOW 5 to 0 full counter cloc...

Page 15: ...d FINE TUNE 4A Panel Controls so the DPO VCO A pitch matches that of the reference DPO VCO B 10 Send note C3 to the DPO and adjust the VCO A 1V Octave Trimmer 3A on the DPO so the pitch matches that o...

Page 16: ...using oscilloscope 5 If using an oscilloscope or spectrum analyzer adjust so the SINE shape is pure as possible meaning both the top and bottom arches are smooth rounded and glitch free and harmonics...

Page 17: ...s a SPIKE 6 Set SHAPE to 100 and check that the maximum shape waveform appears as it did at end of step 4 If not adjust SHAPE trim 3 minimally splitting the difference between the optimal maximum sett...

Reviews: