5) Built-in DIP Sw itch

 

AL-2016A 

 

NO. 

Function 

Setting 

ON 

ON 

Remotely Control by phone (Def ault is “ON”) 

OFF 

ON 

ON 

Switch for restoring password (Def ault is “2”), when forgot 

password, please open the cov er of mainframe, pull the 

switch from “2” to “ON”, then power off, power on after 

2sec., pull it to be “2” again. Password restored to be 

“000000” 

OFF 

ON 

ON 

Arm/Disarm dial CMS or not (Def ault is “3”). If pull to “ON” 

and input CMS No. & User ID, it will dial CMS, when 

Arm/Disarm. Pull to “3”, it will not dial CMS when 

Arm/Disarm. 

OFF 

Undefined

 

 

AL-2016A GSM 

 

NO. 

Function 

Setting 

ON 

ON 

Switch f or restoring password(Def ault is “1”), when 

f orgot password, please open the cover of mainf rame, 

pull the switch f rom “1” to “ON”, then power off, power 

on after 2sec., pull it to be “1” again. Password restored 

to be “000000” 

OFF 

ON 

ON 

Sending SMS & dial CMS or not, when Arm/Disarm 

(Def ault is “2”). If pull to “ON” and input CMS No., it will 

dial CMS. If no input CMS No., it will send SMS to user. 

OFF 

 

6) Remote Control

 

 

OR

 

 

Button 

Enable/Disable 

Function 

ARM KEY

 

Press

key 

Sound “Bi”, enter normal ARM 

status. 

To be 

Armed  

Press

key  again 

Sound “Bi Bi”, enter mute ARM 

status. 

DISARM 

KEY

 

Press

key 

Disarm immediately & exit 

alarming status 

To be 

Disarmed 

EMERGENCY 

KEY

 

Press

key 

Warn & Dial at once 

To be 

Emergency 

PERIMETER 

ARM KEY

 

Press

key 

Sound “Bi”, enter perimeter 

Armed 

To be 

Perimeter 

Armed  

Press

&

key  at 

the same time 

Enter v ocal armed status without 

any delay. 

Summary of Contents for AL-2016A

Page 1: ...1...

Page 2: ...ic Configure 01 2 Words Explain 02 3 Attention before using 03 4 Feature Function 04 5 Main part instruction 04 6 Setting Operation 10 7 Receive the Alarming phone 19 8 Remote Control Function 21 9 Sy...

Page 3: ...f Siren Warning time of Siren User Password Password for Disarm or remote control 3 Attention before using 1 Make sure all theArming zones are on duty 2 Avoid heavy impact and unnecessary disassembly...

Page 4: ...o selectw ired w ireless PIR sensor Door Sensor Gas Smoke Detector and so on 14 12V output port forwired accessories 5 Main part instruction 1 Main unit front 1 Pow er indicator Always on On duty Off...

Page 5: ...ire directly connect with mainf rame If more than two before connect with mainf rame please connect the detectors in series Wired 3 zone wiring same as above Wired 2 zone wiring same as above Wired 1...

Page 6: ...ult is 1 when f orgot password please open the cover of mainf rame pull the switchf rom 1 to ON then power off power on after 2sec pull it to be 1 again Password restored to be 000000 1 OFF 2 ON ON Se...

Page 7: ...7 6 System Setting and Operation Pow er on LCDw ill be on then operating as below NORMAL 1 PHONE 2 CMS 3 P ASSWORD 4 TIME DATE ADVANCED...

Page 8: ...8 1 LEARN CODE 2 REMOVE...

Page 9: ...9 3 SETTING 4 SELF CHECK 5 ALARM LOG 6 AUTOARM DISARM...

Page 10: ...nw ill be warning in any status Except the above two vocal alarming situation If under mute alarm status the sirenw ill notwarn 2 Phone Alarm When alarming the systemw ill dial in order If not being s...

Page 11: ...r Press 0 key Disarm Sound Bi Bi once Press 1 key ARM Sound Bi once Press 3 key Monitor Local Sound Bi once 9 System Installing 1 Before using allw ireless should learn code Security zone need to be u...

Page 12: ...12 AL 2016A AL 2016A GSM...

Page 13: ...0 5sec 13 Security Zone Wireless 80 Wired 4 11 Normal Fault Solution Fault The possible reasons Solution Power LED is OFF LCD screen does notwork Backup batter run out or power is cut Charge the batte...

Page 14: ...always on Working Method PIC2A Magnetic Stripe abuts against Door Sensor closely and then takes magnetic stripe away more than 20mm LED1 will f lash once sending warning signal Technology Parameter B...

Page 15: ...3 92MHz Transmitting Distance 200m openv iew place PIR Detector Diagram View PIC2A Sensor Germany Hayman Sensor Detecting angle horizontal 100 Vertical 70 Detecting range 6 12m Size 10 7 5 8 4 7cm Wor...

Page 16: ...check mode and the Red LEDw ill be flashing If without being triggered it w ill enter testing mode Code learning mode Under testing or working mode press code learning switch the Green LED will be on...

Page 17: ...7 4 NOTE A Avoid to drop or impacts orw ill cause damage B Avoid touching sensor to keep mirror surface clean C After testing please set to normally work mode D Do regularly checking for better status...

Page 18: ...18...

Reviews: