mak DJ audio 60W SPOT MOVING HEAD User Manual Download Page 20

 

 

 

 

General Troubleshooting 

S

YMPTOM 

 

Breaker/Fuse 

keeps blowing 

 

Device does not 

power up 

 

 

 

 

Fixture is not 

responding to 

DMX 

 

 

 

 

 

 

 

Loss of signal 

P

OSSIBLE

 C

AUSE

(

S

 

Excessive circuit load 

Short circuit along the power 
wires 

No power 

Loose power cord 

Wrong DMX addressing 

Damaged DMX cables 

Wrong polarity settings on the 
controller 

Loose DMX cables 

Faulty DMX interface 

Faulty Main PCB 

Non DMX cables 

Bouncing signals 

Long cable / Low level signal 

Too many fixtures 

Interference from AC wires 

P

OSSIBLE

 A

CTION

(

S

 

Check total load placed on the electrical circuit. 

Check for a short in the electrical wiring (internal and/or 
external) 

Check for power on power outlet 

Check power cord 

Check Control Panel and unit addressing 

Check DMX cables 

 

Check polarity switch settings on the controller 

 

Check cable connections 

Replace DMX input 

Replace Main PCB 

Use only DMX compatible cables 

Install terminator as suggested 

Install amplifier right after fixture with strong signal 

Install an optically coupled DMX splitter after unit #32 

Keep DMX cables separated from power cables or 

black lights 

 
 

 
 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 
 

 
 
 

 
 
 

 
 
 

 
 
 

 
 

5. Appendix 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 
 

 
 
 

 
 
 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

20 

Summary of Contents for 60W SPOT MOVING HEAD

Page 1: ...Use on Dimmer Outdoor Use Sound Activated DMX Master Slave 115 V 230 V Voltage Selection Switch Replaceable Fuse User Serviceable Duty Cycle Snapshot 60W SPOT MOVING HEAD USER MANUAL...

Page 2: ...GING 10 4 OPERATING INSTRUCTIONS 11 CONFIGURING THE STARTING ADDRESS 11 CONTROL PANEL FUNCTIONS 11 MENU MAP 12 DMX OPERATION 13 STANDALONE OPERATION 13 AUTOMATIC FAST 13 AUTOMATIC SLOW 13 SOUND ACTIVE...

Page 3: ...512 50 60 Settings MENU Settings ON MEANING A LCD display to be configured A key to be pressed on the fixture s control panel A range of values A set of values of which only one can be chosen A menu...

Page 4: ...rfaces Be sure that no ventilation slots are blocked Always disconnect from power source before servicing or replacing fuse and be sure to replace with same fuse source Secure fixture to fastening dev...

Page 5: ...ic dimmer 0 100 Remote fixture reset vector speed channel Individual reset of pan tilt color gobo prism focus Move in black for pan tilt color gobo Built in movement macros via DMX automated and sound...

Page 6: ...Product Dimensions 2 Introduction 6...

Page 7: ...Product Overview Front lens Control Panel Standing feet DMX IN Power Fuse Holder DMX OUT 2 Introduction 7 Pan Tilt...

Page 8: ...a rheostat variable resistor or dimmer circuit even if the rheostat or dimmer channel is used only as a 0 to 100 switch Always connect the fixture to a circuit with a suitable electrical ground The ma...

Page 9: ...explanation Fuse Replacement Disconnect the power cord before replacing a fuse and always replace with the same type fuse With a flat head screwdriver unscrew the fuse holder out of its housing turni...

Page 10: ...Please see the following steps for installation If the power link out is intended to be used with multiple fixture take into account the length of each power cable and mount the fixtures close enough...

Page 11: ...DMX channels If this is your first time using DMX we recommend reading the DMX Primer section in the Appendix Control Panel Functions Access control panel functions using the four buttons located dir...

Page 12: ...Menu Map 4 Operating Instructions 4 Operating Instructions 4 Operating Instructions 3 Setup 3 Setup 3 Setup 2 Introduction 2 Introduction 2 Introduction 12...

Page 13: ...on the LCD screen 2 Press ENTER 3 Select AUTOFAT 4 Press ENTER This fixture has preprogrammed slow chases These are accessed via the control panel Please see the Instructions Below for further explana...

Page 14: ...ol panel It is not necessary to arrange the master fixture as the first fixture in the daisy chain It may be any fixture in the daisy chain For example fixture 2 5 10 or 12 etc Only 1 fixture may be s...

Page 15: ...ed 192 255 Rotating counter clockwise with increasing speed 8 Gobo Rotation 000 009 NO Function 010 116 Rotate clockwise slow fast 117 244 Rotate counter clockwise slow fast 245 255 Gobo bounce CHANNE...

Page 16: ...o 1 038 056 Gobo 2 057 075 Gobo 3 076 094 Gobo 4 095 113 Gobo 5 114 127 Gobo 6 128 191 Rotating clockwise with increasing speed 192 255 Rotating counter clockwise with increasing speed 8 Gobo Rotation...

Page 17: ...e to female connectors The shield connection is pin 1 while pin 2 is Data Negative S and pin 3 is Data positive S General Maintenance To maintain optimum performance and minimize wear fixtures should...

Page 18: ...es that can carry a high quality signal and are less prone to electromagnetic interference DMX Data Cable Use a Belden 9841 or equivalent cable which meets the specifications for EIA RS 485 applicatio...

Page 19: ...lowing fixture and so on Pin 4 Pin 5 Universal DMX Controller This drawing provides a general illustration of the DMX input output panel of a lighting fixture Continue the link Setting the Starting Ad...

Page 20: ...y fixtures Interference from AC wires POSSIBLE ACTION S Check total load placed on the electrical circuit Check for a short in the electrical wiring internal and or external Check for power on power o...

Page 21: ...sh Power Consumption 230 VAC 50 Hz 144 W 0 5 A max 1 A inrush Power output 4 units max Fuse F 2 A 250 V LIGHT SOURCE LED 1 white 60 W 13 5 A 50 000 hrs PHOTOOPTIC Luminance 1 m 18 000 lux Beam Angle 1...