background image

5 6 ,  c h e m i n   d e   l a   F l a m b è r e   •   3 1 3 0 0   To u l o u s e   •   F R A N C E   •   T é l .  3 3   ( 0 ) 5   6 1   3 1   8 6   8 7 
Fa x   3 3   ( 0 ) 5   6 1   3 1   8 7   7 3   •   c o m m e r c i a l @ m a j o r c o m . f r   •   w w w . m a j o r c o m . f r

2

5 6 ,  c h e m i n   d e   l a   F l a m b è r e   •   3 1 3 0 0   To u l o u s e   •   F R A N C E   •   T é l .  3 3   ( 0 ) 5   6 1   3 1   8 6   8 7 
Fa x   3 3   ( 0 ) 5   6 1   3 1   8 7   7 3   •   c o m m e r c i a l @ m a j o r c o m . f r   •   w w w . m a j o r c o m . f r

3

PX-6120

6*6 ZONES MATRIX AMPLIFIER WITH MP3/FM/BT PLAYER

Caution : Please read this manual carefully before using it. Damage caused by misuse is not covered by the 

warranty.

1.  Read and keep these instructions

2.  Heed all warnings and follow all instructions.

3.  Do not use this device near water.

4.  Do not block ventilation openings. Install the device according to the manufacturer’s instructions.

5.  Do not install the appliance near heat sources such as radiators, heat vents, stoves or any other heat-producing ap-

pliances.

6.  Donot neglect the safety objective of the polarized plug or grounding plug. A polarized plug has two blades, one being 

wider than the other. A grounding plug has two blades and a third grounding pin. The wide blade or third pin is provided for 

your safety. If the plug provided does not fit your outlet, consult an electrician for the replacement of the obsolete outlet.

7.  Protect the power cord so that it is not trampled or pinched, especially at the plugs, power outlets and where it comes out 

of the device

8.  Use only accessories specified by the manufacturer.

9.  Use only the cart, stand, tripod, console or table specified by the manufacturer or sold with the device. When using a 

trolley, be careful when moving the trolley/appliance assembly to avoid injury due to tipping.

10.  Unplug this device during thunderstorms or when not in use for long periods of time

11.  Entrust all repairs to qualified personnel. Maintenance is required when the device has been damaged in any way, such 

as when the power cord or plug is damaged, when a liquid has been spilled or objects have fallen into the device, when the 

device has been exposed to rain or moisture, when it is not working normally or when it has fallen

12.  This device should not be exposed to drops of water or splashes and no liquid-filled objects, such as a vase, should be 

placed on the device

13.  Plug this device into the appropriate wall outlet and make the plug to be unplugged easily usable.

14.  The main plug shall be used as a disconnection device and shall remain easily usable during the intended use. In order 

to completely disconnect the device from the mains, the mains plug must be completely disconnected from the power outlet

15.  WARNING: To reduce the risk of fire or electric shock, do not expose this device to rain or moisture.

16.  An appliance with a protective ground terminal must be connected to a power outlet with a protective ground connection.

SUMMARY

1. SAFETY WARNINGS

1. SAFETY WARNINGS...................................................................................................................p. 3
2. INTRODUCTION........................................................................................................................... p.4

 

2.1 DESCRIPTION GÉNÉRALE...........................................................................................

p.4

 

2.2 FRONT PANEL.................................................................................................................

p.5

 

2.3 BACK PANEL....................................................................................................................

p.6

3. USER GUIDE.................................................................................................................................p.6  

 

3.1 CONNECTION AND CONFIGURATION

........................................................................p.6 

 

3.2 DIP SWITCHES

............................................................................................................... p.7

 

3.3 ACTIVATION OF PRIORITIES AND EMERGENCIES

................................................. p.7

 

3.4 SIGNAL INPUTS AND OUTPUTS.....

.............................................................................p.7  

 

3.5 SPEAKER OUTPUTS......................................................................................................p.8

 

3.6 100V LINE SYSTEMS...........

...........................................................................................p.8

 

3.7 LOW IMPEDANCE SYSTEMS.......

.................................................................................p.8  

 

3.8 MEANING OF LED DISPLAY

..........................................................................................p.9

 

3.9 OPERATION.............

........................................................................................................p.9

 

3.10 EMBEDDED MULTI-SOURCE AUDIO PLAYER......

....................................................p.9

 

3.11 BLUETOOTH OPERATION

.........................................................................................p.10

 

3.12 TUNER FM

....................................................................................................................p.10

 

3.13 USB/SD DRIVE............................................................................................................p.10

4. APPLICATION..............................................................................................................................p.11
5. TECHNICAL CHARACTERISTICS............................................................................................p.12

6*6 ZONES MATRIX AMPLIFIER WITH MP3/FM/BT PLAYER

PX-6120

User manual

Manuel d’utilisation

TO PREVENT FIRE OR SHOCK HAZARD, DO NOT USE THE PLUG WITH AN EXTENSION CORD, RECEPTACLE OR 

OTHER OUTLET UNLESS THE BLADES CAN BE FULLY INSERTED TO PREVENT BLADE EXPOSURE. 

TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS APPLIANCE TO RAIN OR MOISTURE. 

TO PREVENT ELECTRICAL SHOCK, MATCH WIDE BLADE PLUG TO WIDE SLOT, FULLY INSERT.

CAREFUL !

The exclamation point within an 

equilateral triangle is intended to alert 

the user to the presence of important

operating and maintenance 

(servicing) instructions in the literature 

accompanying the appliance.

The  lightning  flash  with  arrowhead 

symbol within an equilateral triangle 

is intended to alert the user to

the presence of uninsulated «dangerous 

voltage» within the product’s enclosure that 

may  be  of  sufficient  magnitude  to  constitute

a risk of electric shock to persons.

WARNING 

:  TO  REDUCE  THE  RISK  OF 

ELECTRIC  SHOCK,  DO  NOT  REMOVE 

COVER (OR BACK). NO USER SERVICEABLE 

PARTS  INSIDE.  REFER  SERVICING  TO 

QUALIFIED 

SERVICE 

PERSONNEL.

RISK OF ELECTRIC SHOCK

DO NOT OPEN

CAUTION

Summary of Contents for PX-6120

Page 1: ...Manual to download in PDF format on www majorcom fr PX 6120 USER MANUAL 6 6 ZONES MATRIX AMPLIFIER WITH MP3 FM BLUETOOTH PLAYER...

Page 2: ...a vase should be placed on the device 13 Plug this device into the appropriate wall outlet and make the plug to be unplugged easily usable 14 The main plug shall be used as a disconnection device and...

Page 3: ...LM 6000 M 6000 Mic1 Mic2 Mic3 Trigger EMC Selective announcement microphone 6 zones Designed for all in one use that requires different audio sources USB SD FM audio player and built in remote control...

Page 4: ...to Mic Line 1 2 and 3 inputs 27 28 30 using good quality audio cables A stereo or mono line level source can be connected to the input of auxiliary channel 4 on 2 RCA connectors 26 To check the output...

Page 5: ...e 1 If you want to play your MP3s press the Z1 button on the MP3 line zone 1 will receive MP3 music and the screen in zone 1 will show C1 If zone 1 cannot be heard from the location of the P X 6120 us...

Page 6: ...back panel using a good quality RF coaxial cable If no channels are tuned in press the Play button to start auto tune which scans available stations and stores them as stations in the P X 6120 s FM t...

Page 7: ...microphone Up to 6 RM 6000 per matrix Volume source wall plate Up to 6 LM 6000 per matrix Bandwidth 80 Hz 16 000 Hz THD 0 1 S N 70 dB Protection Protection against high temperatures short circuits an...

Page 8: ...l a mb re 31300 To u l o u s e FR ANCE T l 33 0 5 61 31 86 87 Fax 33 0 5 61 31 87 73 co mmerc i a l ma j o rco m fr w w w majorcom fr User manual PX 6120 AMPLIFICATEUR MATRICIEL 6 6 ZONES AVEC LECTEUR...

Reviews: