Version: 2.0, 18.11.2011    

General 

No matter if fixed installation or touring business – complex lighting systems always 
require best reliability together with relatively easy operation and maintenance 
features. In order to be able to solve eventually occurring problems not only fast but 
also most efficiently, it is important to know which component of the system fulfils 
which purpose. 

This fact has been taken into consideration during the design and development of 
Rainbow Colour Changers. And this is why we find the entire “intelligence” where we 
first expect it to be: within the Colour Changers themselves, but not in the power 
supply unit. Consequently the DMX-addressing, the selection of channels, etc... is 
done right on the Colour Changer itself. 

The external power supply unit (PSU) combines the DMX signal with the internal 24 V 
DC of the Colour Changer. These power/control signals are available on the female 
XLR4 outputs. 

 

Different versions 

In order to meet your individual demands, we offer two different PSU-versions: 

the MICRO PSU with 1 output is able to run up to 6 Colour Changers 

the MAXI PSU with 4 outputs can run up to 24 units 

 

The maximum number of Colour Changers per output is restricted:  

 

 

 

 

 

 

 

 

 

PSU 

max. no. of 
units (altogether) 
 

max. no. of 6”, 8”, 
12” per output  

max. no. of 15”, 
8-Lite per output 

 

Micro   

  6 

  6 

Maxi 

24 

12 

 

Power Supply 

The Micro PSU as well as the Maxi PSU are connected with the mains via powerCON 
connection. The necessary operating voltage of the Colour Changers (24 V) is 
guaranteed by the opto-isolated, overload-protected power supply. 

The PSUs adjusts itself automatically to the operating voltage from 100 to 240 Volt. 

 

 

Summary of Contents for Maxi 4 PSU

Page 1: ...Power Supply Unit PSU Maxi PSU Micro PSU Manual ...

Page 2: ... or publish any part of this manaul neither in printed form nor by photos or electronic media All technical specifications are subject to change without Notification Contact service and support Germany und Europe Lightpower GmbH An der Talle 24 28 33102 Paderborn Telefon 49 5251 1432 20 Fax 49 5251 1432 80 E Mail info lightpower de Web www lightpower de ...

Page 3: ...t on the Colour Changer itself The external power supply unit PSU combines the DMX signal with the internal 24 V DC of the Colour Changer These power control signals are available on the female XLR4 outputs Different versions In order to meet your individual demands we offer two different PSU versions the MICRO PSU with 1 output is able to run up to 6 Colour Changers the MAXI PSU with 4 outputs ca...

Page 4: ...SU The outputs to the scrollers are designed as XLR4pol sockets which are connected with the XLR4pol male socket of the first Colour Changer in line via Major Power Data cables Further scrollers are connected from the XLR4pol female socket of the first Colour Changer in line to the second one etc In order to improve current feeding and DMX transmission we always recommend to connect a so called re...

Page 5: ...increases the maximum cable length which you can use within the system In order to ensure a reliable operation you should not use more than 300 m total cable length theoretical figure per output Please note that you have to differentiate between the theoretical cable length and the actually usable cable length Example 1 Actually usable cable length 145 m see systemdrawing 2 Theoretical cable lengt...

Page 6: ... 24 V DC supply is OK When the termination switch is activated the red LED is flashing The green LED indicates that a DMX signal is present at the XLR5pol input The Micro PSU has three LEDs The yellow LED indicates that the termination switch is activated The red LED shows if the 24 V DC supply is OK The green LED indicates that a DMX signal is present at the XLR5pol input ...

Page 7: ...to isolated DMX512 input low load Yes Switch for termination of the DMX512 input Yes Connector Mains powerCON blue Mains input 100 240V Volt AC Standard Max number of units altogether 6 x 6 8 12 PRO or 3 x 15 8 Lite PRO Max number of scroller per output 6 x 6 8 12 PRO or 3 x 15 8 Lite PRO CE approval 2006 95 EG Niederspannungsrichtlinie 2004 108 EG Elektromagnetische Verträglichkeit EN 60204 1 Sic...

Page 8: ...x 293 x 250 Weight 3 3 kg 7 3 lbs Connectors Out to scrollers XLR 4 pin F Connectors Return from scroller XLR 4 pin M Connector DMX512 input XLR 5 pin M Connector DMX512 output XLR 5 pin F Opto isolated DMX512 input low load Yes Switch for termination of the DMX512 input Yes Connector Mains Standard ...

Page 9: ...5 8 Lite PRO Max number of scroller per output 12 x 6 8 12 PRO or 6 x 15 8 Lite PRO CE approval 2006 95 EG Niederspannungsrichtlinie 2004 108 EG Elektromagnetische Verträglichkeit EN 60204 1 Sicherheit von Maschinen Protection class I Accessories 210474 Schukocable 280178 1 Saveking ...

Page 10: ...10 Version 2 0 18 11 2011 ...