1. INTRODUCTION

MT222 is a sensor for sensing AC High Voltage. It provides electric 
engineering personnel, power engineering personnel, firefighting 
personnel and instrument equipment workers with prominent warning 
when approaching high voltage and for taking necessary safety action, 
preventing illusion and misjudgment which could lead to electric shock to 
person.
When a person wearing MT222 is approaching high voltage source or 
equipment, the sensor will detect automatically and buzzer will generate a 
"BeBe" sound for warning and LED will flash to remind operators that the 
user is approaching a high voltage sauce and special attention shall be 
given to the safety of operations.

2. FEATURES

●  Designed for detecting un-shielded cables. If the shielding of the cable is 

connected to the ground, it can't work.

●  Compact, easy to wear and convenient in use.
●  Usable both indoor and outdoor.
●  Water-proof design. (IP65)
●  Equipped with self-testing functions.
●  Sound and flash light warning on different frequencies varied positively 

with sensed voltages.

●  Able to sense all kinds of AC High Voltage System.
●  Low power consumption.
●  Meets : EN 61326-1.
●  CE Certified.
●  Voltage detection :

Voltage 

 

Detection  

Detection 

 

 

angle 

distance

6.6kV 

 

90°   

40cm ± 20%

(3.8kV phase to ground)

11.4kV 

 

90°   

55cm ± 20%

(6.6kV phase to ground)

19.7kV 

 

90°   

80cm ± 20%

(11.4kV phase to ground)

22.8kV 

 

90°   

85cm ± 20%

(13.2kV phase to ground)

Summary of Contents for MT222

Page 1: ...INSTRUCTION MANUAL 22kV AC VOLTAGE DETECTOR MT222 ...

Page 2: ...2 ...

Page 3: ...3 Contents Page no 1 Introduction 4 2 Features 4 3 Specifications 5 4 Method Of Use 5 5 Cleaning Replacing Battery 6 6 Cautions 6 7 Combinations of the Detector 7 ...

Page 4: ...r is approaching a high voltage sauce and special attention shall be given to the safety of operations 2 FEATURES Designed for detecting un shielded cables If the shielding of the cable is connected to the ground it can t work Compact easy to wear and convenient in use Usable both indoor and outdoor Water proof design IP65 Equipped with self testing functions Sound and flash light warning on diffe...

Page 5: ...stic cord x 2 Battery Hook x 3 Elastic cord adjustment x 1 Connection ring x 2 Range 3 SPECIFICATIONS 4 METHOD OF USE 4 1 Inspection before use 1 Check the appearance and structure for any abnormality 2 Press Self Test switch about 10 seconds to confirm all functions are working normally 3 To be careful and to avoid misjudgment test the unit by contacting AC 110V 230V insulated wire with its front...

Page 6: ...ak the battery shall be replaced 2 Use coin to open battery cover and remove used battery Place new battery into slot with the battery positive face up and fasten battery cover with coin 6 CAUTIONS 1 This instrument is an auxiliary testing unit and is only for obtaining warning as additional protection Never use this instrument as substitution for Tester Electrical Test shall be the prime electric...

Page 7: ...on and self test to ensure no damage occurred before using again 6 If the instrument is wet by rain remove battery and place it at cool place to dry 7 The MT222 can t detect the HV cable which has an outer sheathing that is connected to the ground COVERING OUTER SHEATING EARTH INSULATION CABLE CORE LINE 7 COMBINATION OF THE DETECTOR S Ÿ eparate the elastic cord and the elastic cord adjustment E Ÿ ...

Page 8: ...nection ring can be assembled T Ÿ he hook can be disassembled 1 The combination of the hook 2 The hook can be adjusted according to the user s requirement Sealed for stuck Buckle Follow the GAP Up Adjustment Down 1 2 ...

Page 9: ...the upper part of the connection ring pass through the elastic cord and one side of the detector Assemble the connection ring firmly A Ÿ ttention this elastic cords strip must be A side A Side 1 A Side A Side 2 A Thick B Thin Correct Incorrect Stuck ...

Page 10: ...t pass through from B side 6 First assemble the connection ring of the other side 7 Take the elastic cord B side pass through the space of the connection ring as below B Side B Side Turn over B Side 8 Turn over the elastic cord pass through the elastic cord adjustment as below B Side 1 2 Attention The second combination is different ...

Page 11: ... 10 Fix the detector to the helmet 11 Short elastic cord Be Ÿfore assembling the connection ring take the upper part of the connection ring pass through the elastic cord and one side of the detector Assemble the connection ring firmly As Ÿsemble the connection ring of the other side of the elastic cord ...

Page 12: ...www major tech com www majortech com au sales major tech com info majortech com au MAJOR TECH PTY LTD South Africa Australia ...

Reviews: