8
7
Range
Resolution
Accuracy
200.0uA
0.1uA
±1.5% of rdg ±5 dgts
2000uA
1uA
20.00mA
10uA
±1.8% of rdg ±5 dgts
200.0mA
100uA
10A
10mA
±3.0% of rdg ±7 dgts
5.4. AC Current (Auto-ranging for uA and mA)
Overload Protection: 0.2A / 250V and 10A / 250V Fuse.
Frequency Range: 50 to 60 Hz
Maximum Input:
200mA DC or 200mA AC RMS on uA /
mA ranges, 10A DC or AC RMS on 10A
range.
Range
Resolution
Accuracy
200A
0.1A
±1.0% of rdg ±3dgts
2000A
1A
(meter only, Clamp-on
Adaptor accuracy not
included)
5.5. Clamp-on Adaptors DC Current
Sensor:
Clamp-on Adaptor
(Note: not provided)
200A Range Input Sensitivity: 1mV/A
2000A Range Input Sensitivity: 1mV/A
Overload protection:
500V DC or AC RMS.
Range
Resolution
Accuracy
200A
0.1A
±1.5% of rdg ±3dgts
2000A
1A
(meter only, Clamp-on
Adaptor accuracy not
included)
5.6. Clamp-on Adaptor AC Current
Sensor:
Clamp-on Adaptor
(Note: not provided)
200A Range Input Sensitivity: 1mV/A
2000A Range Input Sensitivity: 1mV/A
Frequency Range:
50 to 60 Hz
Overload protection:
500V DC or AC RMS.
Summary of Contents for MT22
Page 1: ...INSTRUCTION MANUAL 1000V AC DC MULTIMETER MT22...
Page 2: ...2...