6.3. DC CURRENT MEASUREMENTS
CAUTION:
Do not make 20A current measurements for longer than 30
seconds. Exceeding 30 seconds may cause damage to the
meter and/or the test leads.
1. Insert the black test lead banana plug into
the negative
COM
jack.
2. For current measurements up to 4000μA DC,
set the function switch to the yellow
μA
position and insert the red test lead banana
plug into the
μA/mA
jack.
3. For current measurements up to 400mA DC,
set the function switch to the yellow mA
position and insert the red test lead banana
plug into the
μA/mA
jack.
4. For current measurements up to 10A DC, set
the function switch to the yellow
10A/HZ
/%
position and insert the red test lead banana
plug into the
10A
jack.
5. Press the
MODE
button to indicate "
DC
" on
the display.
6. Remove power from the circuit under test,
then open up the circuit at the point where
you wish to measure current.
7. Touch the black test probe tip to the
negative side of the circuit. Touch the red
test probe tip to the positive side of the
circuit.
8. Apply power to the circuit.
9. Read the current on the display.