![Major tech MT1887 IV Instruction Manual Download Page 17](http://html1.mh-extra.com/html/major-tech/mt1887-iv/mt1887-iv_instruction-manual_3795720017.webp)
7.1. BATTERY INSTALLATION
WARNING:
To avoid electric shock, disconnect the test leads from
any source of voltage before removing the battery cover.
1. Turn power off and disconnect the test leads from the meter.
2. Open the rear battery cover by removing two screws (B) using a
Phillips head screwdriver.
3. Insert the battery into battery holder, observing the correct polarity.
4. Put the battery cover back in place. Secure with the screws.
WARNING:
To avoid electric shock, do not operate the meter until
the battery cover is in place and fastened securely.
NOTE:
If your meter does not work properly, check the fuses and
batteries to make sure that they are still good and that they are
properly inserted.
17
7.2. REPLACING THE FUSES
WARNING:
To avoid electric shock, disconnect the test leads from
any source of voltage before removing the meter cover.
1. Disconnect the test leads from the meter.
2. Remove the protective rubber holster.
3. Remove the battery cover (two "B" screws) and the battery.
4. Remove the six "A" screws securing the rear cover.
5. Gently remove the old fuse and install the new fuse into the holder.
6. Always use a fuse of the proper size and value (0.5A/1000V fast blow
for the 400mA range 10A/1000V fast blow for the 10A range.
7. Replace and secure the rear cover, battery and battery cover.
WARNING:
To avoid electric shock, do not operate the meter until
the fuse cover is in place and fastened securely.