background image

                                                                                              

 

 

Section 1

  

Introduction   

 

1.1 Overview 

The Major Science Mini Horizontal Electrophoresis System series has a 

comprehensive design for several kinds of applications. Its excellent and 

consistent performance delivers accurate and reliable experimental results. 

Furthermore, this series is also offered with the Major Science Minis Power 

Supply series as packages with competitive pricing offerings and great value 

as well as convenience to the user. More importantly, the Mini Horizontal 

Electrophoresis System series is RoHS- compliant and designed to comply 

with CE regulations. 

 

Major Science Mini Horizontal Electrophoresis System series

 offers many 

advantages for nucleic acid separation. Agarose gels are convenient to cast 

and samples are easy to load

The moulded design prevents cracks and 

leakages and the sturdy PC provides a 130°C temperature capacity. The 

safety interlock cover is designed to prevent electrical hazards during 

electrophoresis. It is ideal for several applications, including Northern and 

Southern blotting, Cosmid library restriction analysis, STS screening, 

microsatellite analysis, PCR fragment analysis, RFLP analysis, DNA 

finger-printing and high throughput analysis. 

 

Features: 

 

Less agarose consumption 

 

Less running buffer consumption 

 

Multichannel pipette compatible 

 

Single molded tank 

 

Safety & Ventilation Lid 

 

High temperature capability, 130

°

 

Easy sample loading 

 

Great indications for gel-making and running 

 

No tapes, clamps or springs needed 

 

No direct heat impact from power supply unit 

 

MJ-105A additional features: 

 

Transparent tank and lid 

DOMINIQUE 

DUTSCHER SAS

Summary of Contents for MJ-105A

Page 1: ...Mini Horizontal Electrophoresis System Instruction Manual Catalog No MJ 105A MT 108 www majorsci com service majorsci com Version 10E Date 2018 11 29 D O M I N I Q U E D U T S C H E R S A S...

Page 2: ...83 mm Tray 2x 50 x 83 mm Tray 1x Double Side Comb 6 teeth x 2 12 teeth Prep 1 Marker 2 Prep2 Marker 2 23 teeth 1x Double Side Comb 8 teeth x 2 17 teeth 12 teeth x 2 25 teeth 1x Black Red Power Cord 1...

Page 3: ...ection 2 Technical Specifications 8 Section 3 Installation Instructions 9 Section 4 Operation Instructions 10 4 1 Controls and Features 10 4 2 Start the operation 11 Section 5 Maintenance 15 Section 6...

Page 4: ...is strongly recommended for the user to read the following points carefully before operating this equipment 1 Read and follow the manual instructions carefully 2 Do not alter the equipment Failure to...

Page 5: ...Environmental Conditions Ensure that the instrument is installed and operated strictly under the following conditions 1 Indoor use only 2 95 RH 3 75 kPa 106 kPa 4 Altitude must not exceed 2000 meters...

Page 6: ...rs should check with the manufacturer s instruction to see if the proposed method will damage the equipment Equipment Operation Follow the guidelines below to ensure safe operation of the unit 1 NEVER...

Page 7: ...are convenient to cast and samples are easy to load The moulded design prevents cracks and leakages and the sturdy PC provides a 130 C temperature capacity The safety interlock cover is designed to pr...

Page 8: ...er stand Cast 6 pcs of agarose gel in one time MT 108 additional features Longer tray allows running of bigger fragments to attain higher resolution Two tray options available Contain 1 set of gel mak...

Page 9: ...C Gel Tray Dimension W x L 52 x 60 mm 50 x 83 mm 107 x 60 mm 105 x 83 mm Maximum Gel Thickness 10mm Maximum sample 25 samples Buffer Volume Approx 200 ml Approx 400 ml Lid Safety and ventilation desi...

Page 10: ...rection So make sure that the comb grooves closest to the black electrode are marked 2 Remove the tray 3 Note the position of the cover on the unit This indicates the correct polarity and the correct...

Page 11: ...Features MJ 105A MT 108 Tank Lid Black Red Power Cord 50 x 83 mm Tray Analytical Comb Gel Maker Stand 105 x 83 mm Tray 52 x 60 mm Tray Analytical comb 107 x 60 mm Tray Tank Lid Black Red Power Cord Ge...

Page 12: ...ranslucent crystals These will interfere with sample migration if not completely dissolved Note The gel is suggested to be cooled to between 50 C and 60 C degrees before pouring 3 Install the Gel Tray...

Page 13: ...he electrophoresis tank to 5mm above the gel 4 Load the samples into the wells and then attach the safety ventilation cover Finally connect the power cords to the power supply unit 5 Turn on the power...

Page 14: ...on Caution The fan is NOT water proof please be careful not to spill liquid onto the fan Otherwise the fan may malfunction 3 Switch MBE 300 on whenever users would like to observe the gel 4 For captur...

Page 15: ...resis place the DNA gel onto the center of MBE 300 to capture clearer images 2 Switch MBE 300 on and place MBE HOOD to cover MBE 300 and a DNA gel 3 Observe and capture images of a DNA gel through the...

Page 16: ...rinse with distilled water Air dry before use Some cleaning agents are not supposed to come in contact with the electrophoresis systems such as Acetone Phenol Chloroform Alcohol and Alkalis If you ha...

Page 17: ...synthetic paper hood are included MJA MBEP Package of MJ 105A and MBE 300 amber filter lid with fan synthetic paper hood are included Dual Electrophoresis Packages MJAA Mini300 Package of 2 x MJ 105A...

Page 18: ...alytical Comb 8 teeth x 2 for mini gel 17 teeth for midi gel 12 teeth x 2 for mini gel 25 teeth for midi gel MT C03 Analytical Comb 6 teeth x 2 for mini gel 12 teeth for midi gel Prep 1 Marker 2 Prep...

Page 19: ...Electrophoresis Packages For MT 108 Single Electrophoresis Packages Dual Electrophoresis Packages MT Mini300 MJAT Mini300 MJAA Mini300 MJAT Mini300 MTT Mini300 MT 100P D O M I N I Q U E D U T S C H E...

Page 20: ...r the warranty is limited to the receipt of reasonable proof by the customer that the defect is embraced within the terms of the warranty All claims made under this warranty must be presented to Major...

Reviews: