background image

38

10000836

Vermont Castings, Majestic Products RHE Natural Vent Insert

BASIC WARRANTY

 

The  Vermont  Castings,  Majestic  Products  Company  (hereinafter 
referred to collectively as the Company) warrants that your new Vermont 
Castings or Majestic Gas Fireplace/Stove is free from manufacturing 
and material defects for a period of one year from the date of purchase, 
subject to the following conditions and limitations.

EXTENDED LIFETIME WARRANTY

 

The  heat  exchanger,  where  applicable,  and  combustion  chamber 
of every Vermont Castings or Majestic gas product is warranted for 
life against through wall perforation. All appliances equipped with an 
Insta-Flame  Ceramic  Burner  have  limited  lifetime  coverage  on  the 
ceramic burner plaque. Warrantees are made to the original owner 
subject to proof of purchase and the conditions and limitations listed 
on this Warranty Document

COMPONENT WARRANTY

CAST IRON: All external and internal cast iron parts are warranted for a 
period of three years.

 

Note

: On porcelain enamel finished external parts and accessories The 

Company offers no Warranty on chipping of enamel surfaces. Inspect 
all product prior to accepting it for any damage to the enamel.

 

 The salt air environment of coastal areas or a high humidity environment 
can be corrosive to the porcelain enamel finish. These conditions can 
cause rusting of the cast iron beneath the porcelain enamel finish, 
which will cause the finish to flake off.

 

Dye lot variations with replacement parts and/or accessories can occur 
and are not covered by warranty.

GLASS DOORS: Glass doors are covered for a period of one year. 
Glass doors are not warranted for breakage due to misuse or accident.  
Glass doors are not covered for discoloration or burned in stains due to 
environmental issues, or improper cleaning and maintenance.
BRASS PLATED PARTS AND ACCESSORIES: Brass parts should be 
cleaned with Lemon oil only.

 

Brass cleaners cannot be used.  Mortar 

mix and masonry cleaners may corrode the brass finish.  The Company 
will not be responsible for, nor will it warrant any brass parts which are 
damaged by external chemicals or down draft conditions.
GAS VALVES: Gas valves are covered for a period of one year
ELECTRONIC  AND  MECHANICAL  COMPONENTS:  Electronic  and 
mechanical components of the burner assembly are covered for one year. 
All steel tube burners are warranted for one year.
ACCESSORIES: Unless otherwise noted all components and Vermont 
Castings, Majestic Products company supplied accessories are covered 
for a period of one year.

CONDITIONS AND LIMITATIONS

•  This new Vermont Castings or Majestic product must be installed by 

a competent, authorized, service contractor. A licensed technician, as 
prescribed by the local jurisdiction must perform any installation/service 
work. It must be installed and operated at all times in accordance with 
the Installation and Operating instructions furnished with the product. 
Any alteration, willful abuse, accident, or misuse of the product shall 
nullify this warranty.

•  This warranty is non-transferable, and is made to the original owner, 

provided that the purchase was made through an authorized supplier 
of the Company.

•  The customer must pay for any Authorized Dealer in-home travel fees 

or service charges for in-home repair work. It is the dealers option 
whether the repair work will be done in the customer’s home or in the 
dealer’s shop.

•  If upon inspection, the damage is found to be the fault of the manufacturer, 

repairs will be authorized at no charge to the customer parts and/or 
labor.  

•  Any  part  and/or  component  replaced  under  the  provisions  of  this 

warranty is covered for six months or the remainder of the original 
warranty, whichever is longest.

•  This warranty is limited to the repair of or replacement of part(s) found 

to be defective in material or workmanship, provided that such part(s) 
have been subjected to normal conditions of use and service, after 
said defect is confirmed by the Company’s inspection.

•  The  company  may,  at  its  discretion,  fully  discharge  all  obligations 

with respect to this warranty by refunding the wholesale price of the 
defective part(s)

•  Any installation, labor, construction, transportation, or other related 

costs/expenses  arising  from  defective  part(s),  repair,  replacement, 
or otherwise of same, will not be covered by this warranty, nor shall 
the Company assume responsibility for same. Further, the Company 
will not be responsible for any incidental, indirect, or consequential 
damages except as provided by law.

• 

SOME  STATES  DO  NOT  ALLOW  FOR  THE  EXCLUSION  OR 
LIMITATIONS OF INCIDENTAL AND CONSEQUENTIAL DAMAGES 
OR  LIMITATIONS  ON  HOW  LONG  AN  IMPLIED  WARRANTY 
LASTS, SO THE ABOVE LIMITATIONS MAY NOT APPLY TO YOUR 
CIRCUMSTANCES.    THIS  WARRANTY  GIVES  YOU  SPECIFIC 
RIGHTS AND YOU MAY HAVE OTHER RIGHTS WHICH VARY FROM 
STATE TO STATE. 

•  All other warranties-expressed or implied- with respect to the product, 

its components and accessories, or any obligations/liabilities on the 
part of the Company are hereby expressly excluded.

•  The  Company  neither  assumes,  nor  authorizes  any  third  party  to 

assume on its behalf, any other liabilities with respect to the sale of 
this Vermont Castings, Majestic product

•  The warranties as outlined within this document do not apply to chimney 

components or other non Vermont Castings, Majestic accessories used 
in conjunction with the installation of this product..

•  Damage to the unit while in transit is not covered by this warranty but 

is  subject  to  claim  against  the  common  carrier.  Contact  the  dealer 
from whom you purchased your fireplace/stove (do not operate the 
appliance as this might negate the ability to process the claim with the 
carrier).

•  The Company will not be responsible for:

a)  Down drafts or spillage caused by environmental conditions such 

as near-by trees, buildings, roof tops, hills, or mountains.

b)  Inadequate  ventilation  or  negative  air  pressure  caused  by 

mechanical systems such as furnaces, fans, clothes dryers, etc.

•  This warranty is void if:

a)  The fireplace has been operated in atmospheres contaminated by 

chlorine, fluorine, or other damaging chemicals.

b)  The fireplace has been subjected to prolonged periods of dampness 

or condensation

c)  Any damages to the fireplace, combustion chamber, heat exchanger 

or other components due to water, or weather damage, which is the 
result of but not limited to, improper chimney/venting installation.

d)  Any alteration, willful abuse, accident, or misuse of the product 

has occurred.

IF WARRANTY SERVICE IS NEEDED…

1)  Contact your supplier.  Make sure you have your warranty, 

your sales receipt, and the model/serial number of your  
Vermont Castings, Majestic product.

2)  DO  NOT  ATTEMPT  TO  DO  ANY  SERVICE  WORK 

YOURSELF.

LIMITED LIFETIME WARRANTY 

PRODUCT COVERED BY THIS WARRANTY

All Vermont Castings gas stoves, gas inserts, and gas fireplaces, and all Majestic or Northern Flame brand gas fireplaces 
equipped with an Insta-Flame Ceramic Burner, or standard steel tube burner.

Summary of Contents for Vemont Castings RHE25

Page 1: ...h Do not use any phone in your building Immediately call your gas supplier from your neighbours phone Follow the gas suppliers instructions If you cannot reach your gas supplier call the re department...

Page 2: ...Venting Instructions 8 Venting and Installation 8 Common Flue Installations 9 Liner Installation 9 Draft Relief Opening 9 Test Chimney Draw 9 Vent Safety System 9 Fan Kit 10 Fan Removal Instructions...

Page 3: ...se appliances are certi ed for installation in a solid fuel burning replace unless using the model HEZC Zero Clearance kit When the Zero Clearance kit is used and the appliance is installed directly o...

Page 4: ...1 mm B 1 38 978 mm 38 975 mm 43 1095 mm A 2 29 743 mm 29 737 mm 33 848 mm B 2 43 1105 mm 41 1065 mm 48 1225 mm A 3 33 838 mm B 3 44 1118 mm A 4 28 712 mm B 4 40 1041 mm A 5 30 775 mm B 5 46 1171 mm C...

Page 5: ...is recessed into the wall and at least 12 305mm above oor level no hearth is required A 3 for RHE25 4 for RHE32 and RHE42 diameter Class B vent must be used when installing the replace insert along wi...

Page 6: ...zero clearance replaces RHE25 RHE32 RHE42 Certi ed To ANSI Z 21 88 2002 CSA 2 33 2002 Vented Gas Fireplace Heaters Preparation Before beginning remove the glass frame from the replace Also check to m...

Page 7: ...ew Nonadjustable HV118 Fig 5 On replaces equipped with the Eurosit 630 gas valves there are brass plugs in two of the holes These plugs are not to be removed The gas inlet hole has a plastic cap in it...

Page 8: ...proved by the authority having jurisdiction Cutting any sheet metal parts of the re place in which the gas replace insert is to be installed is prohibited If the factory built replace has no gas acces...

Page 9: ...be 25 635mm to allow for a 90 offset elbow to be installed FP1354a RHE Flue outlet 6 03 Damper Flue Collar Plate Clamp Chimney Liner Screw Chimney Liner Damper Clamp FP1354 Fig 10 Remove ue collar pla...

Page 10: ...speed control The appliance when installed must be electrically connected and grounded in accordance with local codes or in the ab sence of local codes with the current CSA C22 1 Canadian Electrical...

Page 11: ...nding on the circumstances present Clean glass after rst two weeks of opera tion Glass Frame Removal 1 Remove the top louvre Refer to Louvre Removal section 2 Open the access door 3 Remove two 2 machi...

Page 12: ...0 21 Flame Adjustment RN RP Models L O HI Turn counterclockwise to decrease flame height Turn clockwise to increase flame height HV102 Honeywell hi lo knob 4 5 99 djt Fig 20 Flame adjustment knob for...

Page 13: ...e gas line connection a small amount of air will be in the lines When rst lighting unit with pilot light it will take a few minutes to purge themselves of air Once the purging is complete the pilot an...

Page 14: ...ns exactly B BEFORE LIGHTING smell all around the heater area for gas Be sure to smell next to the oor because some gas is heavier than air and will settle on the oor WHAT TO DO IF YOU SMELL GAS Do no...

Page 15: ...ner tions Jumper wire accross terminals at wall switch if burner comes on replace defective wall switch If okay jumper wires across wall switch wires at valve if burner comes on wires are faulty or co...

Page 16: ...mocouple carefully following lighting thermocouple Clean and or adjust pilot for maximum ame instructions impingement on thermocouple B Defective automatic valve Turn valve knob to Pilot Maintain ow t...

Page 17: ...um 325mv Adjust Pilot Flame Height All Wiring Connections Replace Thermopile Thermocouple Needs A Minimum of 14mv Defective Valve Turn To Pilot Meter Should Read Greater Than 100 Mv If Not Replace Pil...

Page 18: ...require only an occa sional checkup and cleaning and some may require ad justment If repair is necessary it should be performed by a quali ed technician In order to properly clean the burner and pilot...

Page 19: ...1f 1a 1c 1b 1d 1e 1f 1a 1c 18 9 a b 13 18 17 L O H I PILOT ADJ P I L O T ON OFF 23 a b 21 11 a b 10 a b 22a b 0836 RHE25 32 42 parts 7 02 LOCAL REMOTE ON PILO T OFF L E D 42a b 39a b 44 45 40 43 41a...

Page 20: ...10000672 10000672 10000672 10b Pilot Assembly SIT Prop 10000673 10000673 10000673 11a Pilot Assembly PSE Nat 10001739 10001739 10001739 11b Pilot Assembly PSE Prop 10001740 10001740 10001740 12 Pilot...

Page 21: ...Ceramic Refractory Kit Not Shown JT2TBO KT2TBO 10000851 38 Antennae HW 395783 1 RFN RFP Valve 20003561 20003561 39a RF Valve 8310E Natural 20003719 20003719 39b RF Valve 8310E LP 20003720 20003720 40...

Page 22: ...ol different functions of the appliance Model Function s Controlled MRC1 ON OFF MRC2 ON OFF and Temperature MRC3 ON OFF and Temperature control with a digital and a programmable 24 hour clock IMT Wall...

Page 23: ...mbly 1 Remove the front glass see Glass Frame Removal section 2 Install top and bottom brass trim by using the short est black screw Fig 28 29 3 Install bottom decorative plate by simply sliding it un...

Page 24: ...Bracket into the Cabinet Only for RN RP VALVE units c Install the Control Knob Extensions onto the ap propriate Control Valve Knobs Fig 33 On units tted with a Honeywell brand control valve the locat...

Page 25: ...otice IMPORTANT Only trim panel assemblies approved by Vermont Castings Majestic Products can be used on these products ALL repair parts will be available from your local dealer When ordering always g...

Page 26: ...m top channel and fasten it from the back side 3 Install the trim top de ector and use two 2 screws to fasten it Fig 40 41 4 Remove ALL plastic protective covering from brass trim RHESSD and RHESLD Fi...

Page 27: ...formation The Decorative Front Frame should be installed last after all other work such as gas connections vent ing etc has been completed and thoroughly checked and tested for operation leaks and pro...

Page 28: ...x 965mm 3 SL and SLD trim dimensions are for openings smaller than 29 H x 41 W 736mm x 1040mm 4 SXL trim dimensions are for openings smaller than 32 H x 43 W 813mm x 1092mm RHESS RHESL RHESSD RHESLD R...

Page 29: ...1 deflector 1 03 Side View Trim Top De ector Trim Frame Top Section FP1261a Fig 44 Trim top de ector Key Description RHEBSLP RHEBSLA RHEBXLP 1 RHEBXLA 1 1 Trim Frame Flat Black 57926 57926 2 Trim Top...

Page 30: ...brass trim top as shown small end up to prevent heat discoloration Glass Frame FP1291 Fig 46 Position brass trim to with small end up FP1292 bottom channel 2 03 Bottom Decorative Plate FP1292 Fig 47...

Page 31: ...an Speed Control Box to the Bracket Fig 50 and install the Bracket into the Cabinet Only for RN RP VALVE units c Install the Control Knob Extensions onto the ap propriate Control Valve Knobs Fig 51 On...

Page 32: ...eel frame Fig 55 KT205 Bay Front remove fan control box 3 19 01 djt Fan Control Box KT205 Fig 49 Remove fan control box KT207 Bay Front attach fan control box HEDV30 HEDV32 3 19 01 djt Fan Control Box...

Page 33: ...828 PB 52828 AB 3 Top Louvre Grill Assembly 1301199 1341199 1301199 57945 4 Bottom Louvre Grill Assembly 57947 5 Control Door 1301200 1341200 1301200 57946 6 Bottom Louvre Left 1301219 1341219 1301219...

Page 34: ...riser kit should only be used with the RHEBSL RHEBXL trim Riser Trim Dimensions Length A Height B Depth C RHER1 Riser 1 42 1067mm 1 25 6mm 2 55 64 8mm RHER2 Riser 2 42 1067mm 2 50 9mm 2 58 65 6mm RHE...

Page 35: ...penings smaller than 30 H x 42 W 781mm x 1089mm LP trim dimensions are for openings smaller than 33 H x 48 W 846mm x 1225mm C2 RHE42FP Trim For use with RHEDV42 RHE42FP Flat face louvres with polished...

Page 36: ...not remove existing glass with frame Trim Assembly 1 Reposition controls a Remove the Fan Speed Control Box Fig 62 b Attach the Fan Speed Control Box to the Bracket Fig 61 and install the Bracket int...

Page 37: ...e used on these products ALL repair parts will be available from your local dealer When ordering always give the following information Model and serial number part description with nish and part numbe...

Page 38: ...home or in the dealer s shop Ifuponinspection thedamageisfoundtobethefaultofthemanufacturer repairs will be authorized at no charge to the customer parts and or labor Any part and or component replace...

Reviews: