22
10000836
Vermont Castings, Majestic Products RHE Natural Vent Insert
Optional Accessories
Ceramic Refractory
Optional for RHE25 and RHE32
Model Description
RHE25CR
Ceramic Firebox Liner
RHE32CR
Ceramic Firebox Liner
RHE42CR
Ceramic Firebox Liner
1. Remove front glass (Refer to Glass Frame Removal
section)
2. Remove logs from unit.
Logs may be hot!
3. Remove refractory from packaging.
Refractory are fragile and must be handled
with care. Where at all possible, two hands
should be used when handling.
4. Take center refractory and tilt so bottom edge slides
into support angle in back of fireplace.
5. Now press center refractory to back side of fireplace
and hold in place.
6. Take left or right refractory and align it so leading
edge faces outward. Place refractory in fireplace
side and slide it back to support center refractory.
7. Install metallic piece in the leading edge (RHE32
only).
8. Repeat Step 6 and 7 for remaining side refractory.
When side refractory is installed correctly, the
center refractory will be supported by the side
refractory.
9. Fasten top tab supports against refractory to hold
sides in place.
Clearance Kit and the requirements of the Air Kit when
planning out the installation.
Follow the instructions supplied with the Zero Clear-
ance Kit carefully for proper installation.
Remote Controls
Optional remote control units are available to control
different functions of the appliance.
Model Function(s) Controlled
MRC1
ON/OFF
MRC2
ON/OFF and Temperature
MRC3
ON/OFF and Temperature control
with a digital and a programmable
24 hour clock
IMT
Wall mounted thermostat control
FP1287
Ceramic Refractory
2/03
Left Side
Center
Right Side
Leading
Edge
Bottom Edge
FP1287
Fig. 26
Ceramic refractory.
Leading
Edge
A Trim Options for RHE25
A1 RHE25SSP, RHE25LP
Trim Assembly
RHE25SSP
1. Install trim channels (left and right sides). Use two
screws to assemble each piece.
2. Slide on the trim top channel and fasten it from the
back side.
3. Install the trim top deflector using two screws.
4. Remove ALL plastic protective covering from brass
trim.
FP1261
deflector
1/03
Trim Top Deflector
Trim Frame Top Section
Side View
FP1261a
Fig. 27
Trim top deflector.
Zero Clearance Kit
For installations other than in existing woodburning fire-
places such as new construction or renovation projects,
a Zero Clearance Kit must be used. The HEZC enables
these inserts to be installed in combustible environ-
ments. It is recommended that an Air Kit (AKZC) be
installed whenever using a Zero Clearance Kit. Con-
sideration must be given to the dimensions of the Zero
HE25LP
1. To install the kit you do not have to remove any
piece of brass, you just add the external pieces.
2. Remove the frame trim from the unit if it is already
installed.
3. Install trim channels (left and right sides) by remov-
ing the two screws that hold the side brass trim and
put them back to hold both parts.
4. Slide on the trim top channel and fasten it from the
back side.