BV4536, BV5142 Natural Vent Gas Fireplace

TROUBLESHOOTING

ELECTRONIC IGNITION

START

1.  Turn gas supply off.
2.  Turn ON/OFF switch to “ON”
  Power to module (24V Normal)

YES

 

Is there a spark across 

 ignitor sensor gap?

YES

Turn on gas. 

Does pilot burner light?

YES

Does spark stop when pilot is lit?

YES

Does main burner light?

YES

Does system run until ON/OFF switch

 is in “OFF” position?

YES

END OF TROUBLESHOOTING 

Check:  Line voltage (120VAC)
 

Low voltage transformer (19.5 minimum VAC)

 

ON/OFF switch

 

Wiring connections 

  Unplug ignition lead and 
  check spark at module   

 

 

(24VAC normal). 

 

Is spark OK? 

NO 

 

YES

A. Check ignition cable ground wiring, ceramic insulator and gap. 

Correct if necessary.

B. Does ignition cable show signs of melting or buckling?  

Take protective action to shield cable and boot from

 

excessive temperatures.

 

A. Are all manual gas valves open?
  Are supply tubing and pressure good?
  Are pilot burner ori

es blocked?

B. Check electrical connections between module and pilot 

operator on gas control.

C. Check for 24VAC across PV-MVPV terminals.
 

If voltage is correct, replace gas control.

 

If voltage is not correct, replace module.

 

NOTE: If

 

Module goes into lockout, reset system.

A. Check continuity of ignition cable and ground wire.
B. Clean 

ame rod.

C. Check electrical connections between 

ame rod and module.

D. 

Is ceramic flame rod insulator cracked?

E. 

Is pilot flame a steady blue? Does flame cover flame rod?

 

If not, adjust pilot flame. Replace module if problem persists.

A. Check for 24VAC across MV-MVPV terminal. 
 

Replace module if there is no voltage.

 

B. Are electrical connections between module and gas 

control good?  

If connections are good, replace gas control or gas 
control operator.

NOTE: If Module goes into lockout, reset system.

A. Check continuity of ignition cable and ground wire.
 

NOTE: If ground is poor or erratic, shutdown may 
occasionally occur even though operation is normal at 
time of checkout.

 

B. 

Is pilot flame a steady blue? Does flame cover flame rod?

NO

NO

NO

NO

NO

NO

Replace module

FP2031
Electronic trblsht

If above checks out, replace module

Summary of Contents for Super B-Vent Series BV4536

Page 1: ...ncy or the gas supplier WARNING Improper installation adjustment alteration services or maintenance can cause injury or property damage Refer to this man ual For assistance or additional information c...

Page 2: ...Up 11 Vertical Venting w Elbows 12 Install Vent Components 12 Firestop Installation 13 Vertical Termination 14 Outside Air Kit 15 Fireplace Installation 16 Check Gas Type 16 Installing Gas Piping to...

Page 3: ...To prevent performance problems do not use propane LP fuel tank of less than 100 lbs capacity 3 If you smell gas shut off gas supply do not try to light any appliance do not touch any electrical swit...

Page 4: ...same atmospheric pressure zone as the combustion air inlet to the appliance 23 For Massachusetts Residents Only This product must be installed by a licensed plumber or gas fitter when installed withi...

Page 5: ...is found Do not install any unit with damaged incomplete or substitute parts Check your packing list to verify that all listed parts have been received You should have the following Fireplace Firebox...

Page 6: ...as Fireplace FIREPLACE DIMENSIONS Figure 1 BV4536 Dimensions 45 36 2256O 3356O 2356O 11 6M 41 26 756O 4456 2 6 756M 412001 BV4536 dims 51 42 2556O 3956O 2356O 11 6M 41 26 756O 4456 2 6 756M 412001 BV5...

Page 7: ...eaders may rest on the top of the firebox standoffs The firebox may be installed directly on a combustible floor or raised on a platform of an appropriate height When the firebox is installed directly...

Page 8: ...t edition and Local Building Codes for specific installation requirements WALL and CEILING CLEARANCE REQUIREMENTS Ensure that minimum clearances shown in Figure 4 are maintained Left and right clearan...

Page 9: ...e appliance is a zero clearance fireplace with ribs spacers defining the minimum space to the sheet metal outer shell Combustibles may be placed up against these spacers Do NOT place combustibles i e...

Page 10: ...ntified in this manual NOTE Any remote wiring i e remote control and wall switch must be done prior to final finishing to avoid costly reconstruction 0 FINISHING MATL Combustible Finishing Material Hi...

Page 11: ...r must follow these safety rules Wear gloves and safety glasses for protection Use extreme caution when using ladders or when on rooftops Be aware of electrical wiring locations in walls and ceilings...

Page 12: ...nents Be certain that each section is locked properly 3 Where necessary add support brackets Figure 9 Incline runs must be supported every 3 Vertical runs must be sup ported every 8 using wall straps...

Page 13: ...ing using the center point 5 Frame the hole with framing lumber the same size as the ceiling joists Position firestop If attic is above mount firestop on top of framing Figure 10 If room is above moun...

Page 14: ...10 12 to 11 12 3 3 Over 11 12 to 12 12 4 Over 12 12 to 14 12 5 Over 14 12 to 16 12 6 Over 16 12 to 18 12 7 Over 18 12 to 20 12 7 6 Over 20 12 to 21 12 8 Figure 12 Minimum Vent Height for Various Roof...

Page 15: ...product into the living area OUTSIDE AIR KIT INSTALLATION 1 Attach aluminum flexible hose to outside air door on the appliance securing it with a spring clamp 2 Cut a hole through outside wall place o...

Page 16: ...rner system regulator damage could occur Install external regulator with the vent pointing down as shown in Figure 14 Pointing the vent down protects it from freezing rain or sleet WARNING A qualified...

Page 17: ...the gas to the fireplace Check your building codes for any special requirements for locating equipment shut off valve to fireplaces Apply pipe joint sealant lightly to male threads This will pre vent...

Page 18: ...from the gas meter to the fireplace for leaks Use a solution of 50 50 water and soap or a gas sniffer 4 To adjust flame height turn HI LO knob to HI to get maximum pressure to burner Turn HI LO knob t...

Page 19: ...only be performed by a qualified licensed electrician Main power must be off when connecting to main electrical power supply or performing service All wiring shall be in compliance with all local city...

Page 20: ...ver at junction box for your wall switch Pilot must be lit and the valve control knob turned to the ON position Meter leads must be con nected to the TP and TH TP terminals on the control valve Turn R...

Page 21: ...off any gaps at the top and sides between the fireplace and the finishing to prevent cold air leaks Refer to Page 10 Figure 6 for allowable locations for combustible materials ROCK WOOL PLACEMENT Roc...

Page 22: ...ve and discard the two 2 screws that secure the C Channel below the top opening of the fireplace 2 Attach bottom rail to unit with two 2 sheet metal screws Figure 20 3 Attach top rail to unit with two...

Page 23: ...tion a naturally vented gas fireplace may not be installed in a bedroom or bathroom in the Commonwealth of Massachusetts WARNING Damper must be in open position when appliance main burner is operatin...

Page 24: ...every second Subsequent lighting of the fireplace will not require this purging of air from the gas lines unless the gas valve has been shut off for a long period LIGHTING THE FIREPLACE You may notic...

Page 25: ...the fire department C Use only your hand to push in or turn the gas control knob Never use tools If the knob will not push in or turn by hand don t try to repair it Call a qualified service technician...

Page 26: ...nob pushed in push in and re lease the piezo ignitor button to light the pilot 9 Continue pushing the control knob in for a further 60 seconds to prevent the flame detector from shutting off the gas w...

Page 27: ...ructions If you cannot reach your gas supplier call the fire department C Turn off all electric power to the appliance D Do not use this appliance if any part of it has been under water Immediately ca...

Page 28: ...ation The pilot flame must always be present when the fireplace is in operation Figure 23 The pilot flame has three distinct flames one engulfing the thermopile one engulfing the thermo couple and the...

Page 29: ...y glass that is chipped cracked or broken Replacement glass door assemblies nust be supplied by MHSC WARNING No substitute materials may be used WARNING Handle glass door with care to avoid striking o...

Page 30: ...ocouple connection at the gas valve is fully inserted and tight Disconnect the thermocouple from the valve place one mil livolt lead wire on the tip of the thermocouple and the other meter lead wire o...

Page 31: ...B Check electrical connections between module and pilot operator on gas control C Check for 24VAC across PV MVPV terminals If voltage is correct replace gas control If voltage is not correct replace m...

Page 32: ...ir pressure A Blockage or restriction in venting ACTION A Install log set per instructions Inspect the injector and air intake area Make sure this area does not have any blockage from debris and clean...

Page 33: ...9 Ref Description Qty BV4536 BV5142 1 Hi Temperature Limit Switch 1 41D0202 41D0202 2 Firebrick Walls T Brown 1 Set FB4536W9TB FB5142W9TB 2a Firebrick Center 1 41D2015 41D2016 2b Firebrick Left Side 1...

Page 34: ...nversion Kits not shown Conversion NG to LP 1 SNPK3642 SNPK3642 Conversion LP to NG 1 SPNK3642 SPNK3642 Standing Pilot Millivolt Control Ref Description Qty BV4536NE BV4536PE BV5142NE BV5142PE 1 Gas V...

Page 35: ...e Limited Lifetime Warranty will also be void if the appliance is not operated and main tained according to the operating instructions supplied with the appliance and does not extend to 1 firebox burn...

Page 36: ...MHSC 149 Cleveland Drive Paris Kentucky 40361 www mhsc com FEBRUARY 2009 41D2001 Rev 6...

Reviews: