Description

The SHR Series fireplaces are solid fuel, woodburn-
ing fireplaces. The SHR36/42A/48 (Super Hearth) are 
clean-face fireplaces.

Precautions

CFM Corporation fireplaces and component parts have 
been highly tested and will operate safely when in-
stalled in accordance with instructions provided in this 
manual. Carefully read and understand all instructions 

before

 beginning installation.

If you notice any damage to fireplace or component 
parts, immediately report damage to your Majestic Fire-
places dealer.
Only use CFM Corporation components or the warranty 
will be voided and a fire hazard may be created.
CFM Corporation warranty will be voided by and CFM 
Corporation  disclaims any responsibility for the follow-
ing actions:

• 

Installation by any other than a qualified 
installer, preferably NFI or WETT (Canada) 
certified.

• 

Installation of any damaged fireplace or chim-
ney component;

• 

Modification of fireplace, chimney assembly 
or any component parts thereof; (except for 
chase flashings as detailed in the Chimney 
Top installation instructions).

• 

Installation other than as instructed by CFM 
Corporation; or

• 

Installation and/or use of any component part 
not manufactured or approved by CFM Corpo-
ration in combination or assembly with a CFM 
Corporation fireplace system, notwithstanding 
any independent testing laboratory or other 
third party approval of such component parts 
or accessory.

Any such action may possibly cause a fire hazard.

Consult local building codes to ensure that you are in 
compliance 

before 

installing the fireplace.

Fireplaces must be vented to the out-of-doors.

Do not obstruct or modify air inlets/outlets in any 
manner. 

Do not install combustible materials on any of the 
black fireplace surround.
Burn only solid wood fuel or gas logs.
Do not install a solid fuel burning insert or other 
products not specified for use with this fireplace.

Proposition 65 Warning:

 Fuels used in gas, wood-

burning or oil fired appliances, and the products of 
combustion of such fuels, contain chemicals known 
to the State of California to cause cancer, birth de-
fects and other reproductive harm.
California Health & Safety Code Sec. 25249.6

WARNING: Check with your electronics manufac-
turer before installing a television or other electron-
ic device above this fireplace.

Drafts

The fireplace should not be located in areas that create 
drafts (ie: frequently opened doors and central heating 
air inlets/outlets) that hamper the normal flow of air into 
the fire.

Gas Logs

If you plan to install a gas log, the gas line should be 
installed before framing the fireplace. The gas line must 
be installed by a certified gas line installer.  

SHR36 / SHR42A / SHR48 / SHR52

Listed

UL 127 / ULC-S610

Standard for Factory Built Fireplaces

Safety Information . . . . . . . . . . . . . . . . . .  2
Specifications and Framing   . . . . . . . . . .  3
Parts Identification  . . . . . . . . . . . . . . . . .  5
Chimney Requirements  . . . . . . . . . . . . .  6
Planning Information . . . . . . . . . . . . . . . .  7
Installation   . . . . . . . . . . . . . . . . . . . . . . .  8
Replacement Parts . . . . . . . . . . . . . . . .  20
Accessories   . . . . . . . . . . . . . . . . . . . . .  21

Table of Contents

Summary of Contents for SHR36

Page 1: ...HR Series Woodburning Fireplace For Models SHR36 SHR42A SHR48 SHR52 Underwriter s Laboratories Report No MH6018 DO NOT DISCARD THIS MANUAL Retain for future use 20001384 4 08 Rev 21 Homeowner s Instal...

Page 2: ...o ration in combination or assembly with a CFM Corporation replace system notwithstanding any independent testing laboratory or other third party approval of such component parts or accessory Any such...

Page 3: ...Gas Line Access Gas Line Access 1365mm FP546A Fig 2 SHR42A Series speci cations and framing SHR42A Series Woodburning Fireplace 36 914mm 46 1175mm 44 1118mm 610mm 189mm 13 Dia 340mm Rough Opening Widt...

Page 4: ...Access Gas Line Access 1518mm SHR48 Series Woodburning Fireplace Fig 3 SHR48 Series speci cations and framing FP545A 9 235mm 52 1321mm 62 1584mm 52 1334mm 838mm 189mm 13 Dia Rough Opening Width 63 Rou...

Page 5: ...att Insulation cut out around restop Firestop Ceiling Level Draftstop Ledge Bracket Surround Damper Control Gas Line Knockout both sides Screen Grate Firebox Metal Safety Strips 1 2 or 3 Outside Air C...

Page 6: ...h to the chimney exit SHR36 SHR42A SHR48 SHR52 Max 90 90 90 90 Min 0 Elbows 14 6 14 6 16 0 16 0 2 Elbows 15 6 15 6 19 0 19 0 4 Elbows 21 0 21 0 24 0 24 0 B Do not use more than 4 elbows per chim ney A...

Page 7: ...2 A chimney cannot be offset more than 30 degrees from a vertical plane 3 A chimney may run straight up or it may be neces sary to offset it to avoid obstructions 4 The maximum length of an angled run...

Page 8: ...how the chimney system should be run contact your Majes tic Fireplaces dealer for assistance Insulating Fireplace Enclosure for Cold Climates If you live in a cold climate it is not required but high...

Page 9: ...corner be hind the end of the left rebrick Push both panels back as far as possible into the left side and corner 4 Swing the right side of the back rebrick into place Attach the left brick in place u...

Page 10: ...hed by using CFM Corporation elbows Use the 30 Offset Elbow table on Page 6 to determine proper offset and parts required Each offset requires two 2 elbows The second elbow is equipped with support st...

Page 11: ...ety strips are not required over noncombus tible oors where all supports at the base of the re place are noncombustible Four 4 nailing anges are supplied with the replace found on the replace hearth T...

Page 12: ...Spacer in the Ceiling Hole A restop spacer is used to keep pipe spaced properly and required for safety Nail the restop spacer at each corner to the framing members of the ceiling hole Note A restop...

Page 13: ...te Run Continue attaching pipe sections to complete system to next level always being careful that the pipe is rmly snap locked in place before proceeding to next pipe section Chimney Supports If chim...

Page 14: ...hase installation CAUTION Treatment of restop spacers and construc tion of chase may vary with type of building These instructions are not a substitute for local building codes You must check your loc...

Page 15: ...in 1 12 305mm Max 12 305mm min 1 6 159mm Min 3 4 FP531 Fig 24 Mantel clearance Header Must be sealed with non combustible material Surround Face Finished Wall Ledge Bracket Finished Wall Ledge Bracket...

Page 16: ...front 12 20 01 djt CAUTION Do Not Place Finishing Ma terial Beyond These Edges or Cover Air Inlets Screen Rail Hearth FP1168 Fig 28 Finishing front of replace MA81 rev 8 5 97 rev 4 18 01 1 Ref MA81 F...

Page 17: ...alue of the al ternate material employed is greater than or equal to R 1 09 Thermal resistance R or thermal conductivity K may be obtained from manufacturer of the material Factors are related by the...

Page 18: ...will vary depending on thickness of noncombustible surround facing 4 Shaded area starts 1 2 away from edge of unit A B C D E F G H J SHR36 20 12 35 42 18 14 8 16 52 508 mm 305 mm 457 mm 356 mm 203 mm...

Page 19: ...Corporation replaces Be sure to have the appliance installed in accordance with building codes Gas connection may enter from either left or right side of the replace Locate appropriate gas line in the...

Page 20: ...0006021 20001431 20005569 4 Screen Rod two per replace 7554181 7554199 20001428 20005790 5 Screen two per replace 7554295 20001723 20001723 20005278 6 Screen Pull two per replace 5584139 5584139 55841...

Page 21: ...accessories for this appliance are available from your local Majestic Fireplaces distributor Should you need additional information beyond what your distributor can furnish contact CFM Corporation 269...

Page 22: ...CFM Corporation Type 11CF Chimney Systems Used to terminate chimney at top of chase Adapter kit included Flashing not included Used to build 11CF chimney systems Used to develop 30 offset chimney sys...

Page 23: ...nstalled in the continental United States the state of Alaska and Canada only if and so long as the Fireplace is installed or serviced by a quali ed installer preferably NFI or WETT Canada certi ed an...

Page 24: ...CFM Corporation 2695 Meadowvale Blvd Mississauga Ontario Canada L5N 8A3 800 668 5323 www cfmcorp com CFM Corporation...

Reviews: