Castings, Majestic Products, 410 Admiral Blvd., Mississauga, Ontario, Canada L5T 2N6, Attn:  Technical Services.

CAUTION: This fireplace and chimney assembly is a highly engineered system, and, as such, must be
operated only with Vermont Castings, Majestic Products approved components.  If you use an unapproved
component to make any modifications, you may create a possible fire hazard and will void the Vermont
Castings, Majestic Products warranty.  In addition, such action may void the coverage provided by the
owner’s insurance.

Glass Door — Standard

Bi-Fold door set

Brushed Brass finish

36GDKBB (SR/C36)
42GDKBB (SR/C42)

Black finish

36GDKBK (SR/C36)
42GDKBK (SR/C42)

Polished Brass finish

36GDKDB (SR/C36)
42GDKDB (SR/C42)

Pewter finish

36GDKS (SR/SC36)
42GDKS (SR/SC42)

Fan Kit

Provides forced air flow

FK12

Variable Speed Control

Provides speed adjustment of fans

SCVS

Outside Air Termination

Completes connection from air kit to out-of-doors AK-MST

Chimney Adapter

Converts fireplace to 3-wall system

TWABR

Hearth Extension Insulation Provides hearth extension floor protection

EH2416

Grate SR/SC36/42

Holds firewood in firebox

RSBG36

Hearth Patch Compound

Patch cracks in hearth

HPC-1

Accessories

Model Number

Description

Accessory

Contact your Vermont Castings, Majestic Products distribu-
tor or dealer for finishing Marble and Mantels, available in a
wide selection of styles.

Summary of Contents for SC36

Page 1: ...678901234567890123 12345678901234567890123 12345678901234567890123 12345678901234567890123 12345678901234567890123 12345678901234567890123 12345678901234567890123 12345678901234567890123 1234567890123...

Page 2: ...ings Majestic Products Chimney Top installation instructions Installation other than as instructed by Vermont Castings Majestic Products or Installation and or use of any component part not manufactur...

Page 3: ...97mm 7 191mm 7 191mm Outside Air Gas Line Access Gas Line Access Electrical Access Recessed Nailing Flange 11 DIA Rough Opening Width 41 Rough Opening Height Rough Opening Depth 3 4 8 7 6 m m 1041mm 1...

Page 4: ...epth 50 1270mm 50 1270mm 3 6 9 1 4 m m 7 0 1 7 9 1 m m 8 210mm 22 559mm 22 572mm 26 667mm 40 1035mm 14 372mm 15 397mm 9 241mm 3 76mm 8 203mm 7 191mm Outside Air Gas Line Access Electrical Access 1194m...

Page 5: ...Fireplace and chase parts identification TERMINATION CAP STORM COLLAR PAN FLASHING DRAFTSTOP FIRESTOP STANDOFF NAILING FLANGE GAS LINE ACCESS both sides ELECTRICAL ACCESS OUTSIDE AIR COVER PLATE DAMPE...

Page 6: ...exit SR SC36 SR SC42 Maximum 90 90 Minimum Without Elbows 12 6 12 6 With 2 Elbows 14 6 14 6 With 4 Elbows 21 0 21 0 B Do not use more than 4 elbows per chimney Attach the straps of the return top elbo...

Page 7: ...of the chimney to the peak of the roof is 10 feet or less the top of the chimney must be at least 2 feet above the peak of the roof but never less than 3 feet in height above the highest point where i...

Page 8: ...A FIRE PLACE IN AN INSULATED ENCLOSURE BE SURE ALL REQUIRED AIR SPACES ARE MAINTAINED Fig 20 Page 14 Installation Chimney Supports The chimney system is supported by the fireplace for vertical chimney...

Page 9: ...Remove knockout in the center of the back of the EB1 and install listed cable clamps Feed electrical wire through listed cable clamp leaving approximately six 6 inches of wire exposed through the EB1...

Page 10: ...pass through ceiling Locate center point of the chimney on ceiling as though a straight up chimney arrangement is to be used Measure your offset dimension from straight up chimney center point on ceil...

Page 11: ...t by attaching the first chimney section to the collar on top of the fireplace Install the pipe as pictured in Figure 16 When you get a good lock you will hear the pipe clearly snap together Once sect...

Page 12: ...lange on the ceiling side and the angled portion extending up into the hole If the area above the ceiling is an attic position the firestop spacer with the flange on the top of the framed hole and the...

Page 13: ...point of the flue system Drive a nail up through roof at the center point This will determine center point on outside of the roof Cut and Frame Roof Hole Size of roof hole varies with the type of chi...

Page 14: ...Fig 20 8 Finish Wall Finish the wall with material of your choice Do not install a combustible mantel shelf less than 12 inches above the grille opening If a combustible material is used below a flat...

Page 15: ...cified for the SP40 Rt must 1 85 minimum Examples of wall shield insulation 1 Manville CERAFORM 126 K 27 1 2 inches thick 2 Majestic EH2416 K 458 1 inch thick required FP531 See mantel drawing for she...

Page 16: ...rial Factors are related by the formula K 1 R T given thickness R thermal resistance for a given thickness T K thermal conductivity Noncombustible material with a lower R value may be used provided th...

Page 17: ...new material per inch K of listed material per inch thickness of listed material x Example for Common Brick T new 5 0 0 458 x 0 50 in 5 46 in new required thickness Fig 24 Hearth extension material f...

Page 18: ...ace side NOTE When installing an ANSI Z21 11 2 ventless appliance the finishing material used for the mantel must be rated at 250 F or greater BTU input of a gas appliance installed in fireplace shoul...

Page 19: ...2 3030172 8 Screen Clips 7512135 7512135 9 Hearth Pan Cover Plate SC Only 3031104 3031104 10 Outer Collar Assembly SK8 Chimney 3030143 3030143 11 Nailing Flange 2253161 2253161 12 Top Grille Assembly...

Page 20: ...h action may void the coverage provided by the owner s insurance Glass Door Standard Bi Fold door set Brushed Brass finish 36GDKBB SR C36 42GDKBB SR C42 Black finish 36GDKBK SR C36 42GDKBK SR C42 Poli...

Page 21: ...ney through CT100 a chase top Appropriate adapter required Flashing not included Adapter Kit Unites Square Chase Termination with chimney CTSK pipe required Chase Top Housing Low profile pyramid style...

Page 22: ...Shield Used to prevent insulation from coming in AIS SK contact with the chimney system SK8 Chimney Sections Used to build chimney systems exposed above SK818CAN 1 Long roof SK84CAN 4 Long 45 Chimney...

Page 23: ...t at a cost to the consumer of Vermont Castings Majestic Products then current list price FOB Vermont Castings Majestic Products factory or pay to the consumer the then current wholesale price of such...

Page 24: ...c Fireplaces SR SC Series Vermont Castings Majestic Products 410 Admiral Blvd Mississauga Ontario Canada L5T 2N6 905 670 7777 www majesticproducts com www vermontcastings com Vermont Castings Majestic...

Reviews: