background image

Portofino Installation Guide

 

Page 5

 

The Majestic Shower Company Limited

 

17 Flitch Industrial Estate, Chelmsford Road, 

Dunmow, CM6 1XJ

 

Telephone (0)1279 443644

 

[email protected]  

www.majesticshowers.com

 

 

 

 
 

  

1A

 Standard Enclosure 

– if you have a bespoke enclosure, please skip to step 1. 

 
 If you have purchased a standard enclosure the underframe for the enclosure will be sent out in identical lengths. 
This means you can turn the enclosure to suit the handing required. The below image shows the left- and right-hand 
enclosures, the below chart tells you the maximum cut that could be required 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

STANDARD 

ENCLOSURE SIZE 

UNDERFRAME SENT 

FRONT 

 

(Maximum Cut)

 

RETURN

  

(Maximum Cut)

 

800 x 800 

790mm x 790mm 

18mm 

18mm 

900 x 800 

890mm x 890mm 

18mm 

118mm 

1000 x 800 

990mm x 990mm 

18mm 

218mm 

1100 x 800 

1090mm x 1090mm 

18mm 

318mm 

1200 x 800 

1190mm x 1190mm 

18mm 

418mm 

800 x 900 

890mm x 890mm 

118mm 

18mm 

900 x 900 

890mm x 890mm 

18mm 

18mm 

1000 x 900 

990mm x 990mm 

18mm 

118mm 

1100 x 900 

1090mm x 1090mm 

18mm 

218mm 

1200 x 900 

1190mm x 1190mm 

18mm 

318mm 

800 x 1000 

990mm x 990mm 

218mm 

18mm 

900 x 1000 

990mm x 990mm 

118mm 

18mm 

1000 x 1000 

990mm x 990mm 

18mm 

18mm 

1100 x 1000 

1090mm x 990mm 

18mm 

118mm 

1200 x 1000 

1190mm x 1190mm 

18mm 

218mm 

 
 

 All Glass has been supplied with an Anti-Calcium coating to the glass which has been supplied on both sides to 
make the glass reversible 

 
             If you have any questions, please contact the office before cutting 
 
 
 
 
 

Summary of Contents for Portofino

Page 1: ...Profiles DO NOT ASSEMBLE WITHOUT FULLY READING THESE INSTRUCTIONS The Majestic Shower Company Limited 17 Flitch Industrial Estate Chelmsford Road Dunmow CM6 1XJ Telephone 44 0 8448 001 500 Facsimile 4...

Page 2: ...Some lean in or lean out of the wall relative to the floor can be accommodated up to 18 mm if 24 mm wall profile is used Floor flatness and levelness or tray rim flatness and levelness if a shower tr...

Page 3: ...1 x Glass Return Panel 1 x Glass In line Panel 1 x Glass Door 2 x Glass to Glass Hinge assemblies with rubber packing strips 4 x Glass to Wall Bracket assemblies for recessed wall profiles with wall p...

Page 4: ...Flitch Industrial Estate Chelmsford Road Dunmow CM6 1XJ Telephone 0 1279 443644 info majesticshowers com www majesticshowers com 1 x Finger Pull Assembly pre installed OR 1 x Door Handle or Towel Rail...

Page 5: ...E UNDERFRAME SENT FRONT Maximum Cut RETURN Maximum Cut 800 x 800 790mm x 790mm 18mm 18mm 900 x 800 890mm x 890mm 18mm 118mm 1000 x 800 990mm x 990mm 18mm 218mm 1100 x 800 1090mm x 1090mm 18mm 318mm 12...

Page 6: ...n on the floor or tray Both sections of the underframe are supplied at maxi mum length to be cut down on site to accommodate any lean in or lean out of the wall relative to the floor For 24 mm wall pr...

Page 7: ...ile If your wall leans inwards cut 0 5 mm from the wall end of the profile if it leans outwards cut 5 10 mm If the wall is at right angles to the floor or tray cut 5 mm from the wall end of the profil...

Page 8: ...nt of silicone in the corners where the underframe will sit against the wall Replace the underframe in position where you have marked the floor or tray and tape it in place whilst the silicone sets In...

Page 9: ...the position of these strips Do not use more than 3 thicknesses of rubber under each panel of glass 11 Disassemble the Glass to Wall brackets being careful not to damage the face plates With the clear...

Page 10: ...erframe channels where the Return panel and In Line panel will sit Do not apply silicone to the underframe where the Insert will be fitted under the door Place a generous amount of silicone into the b...

Page 11: ...as shown Position the door mounting blocks in the underframe channel as shown and lift the door on to the blocks It may be advisable to fit the vertical seal to the In Line panel opposite the hinged...

Page 12: ...the deflector blade back so that it clears the vertical seals both of which should run down to the top of the underframe Open the door and slide the 3 sections of seal on to the edge of the Door pushi...

Page 13: ...hers are located in the holes on both sides of the glass Tighten the grub screws on the inside handle to secure 27 Run a small bead of silicone along the outside edge of the underframe where it meets...

Page 14: ...s com Adjust the bias on the hinges using the 2 small grub screws on the inside and outside of the hinge For an outward opening door the two grub screws on the outside of each hinge should be undone u...