background image

15

Majestic  •  MERIDPLA36IN, MERIDPLA36IL, MERIDPLA42IN, MERIDPLA42IL Owner’s Manual  •  2519-981 Rev. E  •  1/19

DANGER

DANGER

       

-  Wait five (5) minutes to allow possible     

 

          accumulated gas to clear. 

 
       -  Set the IFT-ECM 3-position selector switch to ON  
          or REMOTE position.  Module will beep once and  

          flash a three GREEN LED code on successful 

 

          startup. 

 
       -  If placed in ON position, the appliance will ignite  
          normally if the error condition was corrected. 

 
       -  If placed in REMOTE position, use the paired IFT-   
          RC400, IFT-RC150 or wired wall switch to start  
          the appliance; appliance will ignite normally if the 
          error condition was corrected.

      -  If the IFT-ECM re-enters the lock-out condition 

 

         after these steps, call your dealer for service.

Appliance ON/OFF:

A wall control, thermostat or remote control may be used 
to control the ON/OFF function of the appliance. Follow 
instructions included with the installed control.

IntelliFire

TM

 Touch Ignition System 

NOTICE:  Batteries should not be placed in the battery 

pack while using the transformer. Remove batteries before 

using the transformer, and unplug the transformer before 

installing the batteries. Battery polarity must be correct or 

module damage will occur.

Optional Heat-Zone

®

-Gas Kit

The Heat-Zone

®

-Gas heat management option is avail-

able for use with the MERIDPLA36I and MERIDPLA42I  
appliances. The Heat-Zone

®

-Gas Kit draws heat from 

your fireplace to an adjacent room in your home, up to 

20 feet away.

Optional Heat-Out-Gas Kit

The Heat-Out-Gas heat management option is available 
for use with the MERIDPLA36I and MERIDPLA42I 

 

appliances and must be used in conjunction with the IFT-

RC400 remote control. The Heat-Out-Gas kit draws heat 

from your fireplace and directs it outside, up to 25 feet 

away.

Optional Heat-Duct Kit

The Heat-Duct heat management option is available 
for use with the MERIDPLA36I and MERIDPLA42I 

 

 

appliances.  The Heat-Duct redistributes heat from the 

fireplace via the furnace ductwork. 

Optional Fan Kit 

If desired, a fan kit may be added.  Contact your dealer 

to order the correct fan kit.  Detailed instructions are in

-

cluded with the fan kit.

Heat Management

Summary of Contents for MERIDPLA36IN

Page 1: ...pliance installation manual for additional Commonwealth of Massachusetts requirements DANGER HOT GLASS WILL CAUSE BURNS DO NOT TOUCH GLASS UNTIL COOLED NEVER ALLOW CHILDREN TO TOUCH GLASS A barrier de...

Page 2: ..._______________________________________________________ Gas and Electric Information Serial Number Type of Gas Model Number Not Not for use use with with solid solid fuel fuel Ne Ne doit doit pas entr...

Page 3: ...ications 6 3 Important Safety and Operating Information A Appliance Safety 7 B General Operating Parts 8 C Fuel Specifications 8 D Good Faith Wall Surface TV Guidelines 8 E Before Lighting Appliance 1...

Page 4: ...verage begins on the date of original purchase In the case of new home construction warranty coverage begins on the date of first occupancy of the dwelling or six months after the sale of the product...

Page 5: ...EXCLUSIONS This warranty does not cover the following Changes in surface finishes as a result of normal use As a heating appliance some changes in color of interior and exterior surface finishes may o...

Page 6: ...nd applicable sections of Gas Burn ing Heating Appliances for Manufactured Homes and Recreational Vehicles and Gas Fired Appliances for Use at High Altitudes Installation and service of this appliance...

Page 7: ...en to NEVER touch the fireplace Consider not using the fireplace when children will be present Contact your dealer for more information or visit www hpba org Product Info Fireplace Stove Heater Glass...

Page 8: ...4 B FIXED GLASS ASSEMBLY NOT SHOWN SECTION 4 B MANTEL HEARTH not required FAN KIT SECTION 3 J CLEAR SPACE SECTION 3 A GRATE Figure 3 3 Good Faith Wall Surface Temperatures Above Appliance D Good Faith...

Page 9: ...anufacturer and from model to model actual TV temperatures should be validated at the me of each installa on TVs should not be used in situa ons where the actual TV temperature exceeds the manufacture...

Page 10: ...materials have been removed from inside and or underneath the firebox Review proper placement of logs ember material and or other decorative materials Check the wiring Check the air shutter adjustment...

Page 11: ...ow the gas sup plier s instructions C Use only your hand to push in or turn the gas control knob Never use tools If the knob will not push in or turn by hand DO NOT D DO NOT use this appliance if any...

Page 12: ...the fan speed or to turn the fan OFF The fan speed dynamic icon is used to change the setting G Appliance Break In Follow the initial break in procedure below to cure the materials used to manufactur...

Page 13: ...iring diagram is included in the Electrical section of the appliance Installation Manual 3 Turn the appliance on according to the instructions below for the appropriate type of control Standard Wall S...

Page 14: ...rror When switched to the OFF position while the appliance is operating the system will shut down ON Position The appliance will ignite and run continuously at the HI flame setting No adjustment in fl...

Page 15: ...in the battery pack while using the transformer Remove batteries before using the transformer and unplug the transformer before installing the batteries Battery polarity must be correct or module dama...

Page 16: ...ove freely and no obstructions are present Reinstall decorative front B Maintenance Tasks Homeowner The following tasks may be performed annually by the homeowner If you are uncomfortable performing a...

Page 17: ...ust be performed by a qualified ser vice technician Gasket Seal and Glass Assembly Inspection Frequency Annually By Qualified Service Technician Tools needed Protective gloves drop cloth and a stable...

Page 18: ...lowing embers with new dime size pieces DO NOT block ports or obstruct lighting paths Refer to installation manual for proper ember placement Verify batteries have been removed from battery back up IP...

Page 19: ...glass assembly with care Glass is breakable Avoid striking scratching or slamming glass Avoid abrasive cleaners DO NOT clean glass while it is hot Remove decorative front from fireplace and set aside...

Page 20: ...noise Noise is caused by metal expanding and contracting as it heats up and cools down similar to the sound produced by a furnace or heating duct This noise does not affect the operation or longevity...

Page 21: ...aced in the path of an air draft or vent Move the remote away from the direct path of air flow The remote acts as the thermostat Flame Modulation The control system is designed to automatically adjust...

Page 22: ...no loose connections or electrical shorts in wiring from module to pilot assembly Verify wire insulation is not dam aged Verify wires are not grounding out to chassis pilot burn er or any other metal...

Page 23: ...ted to green main valve solenoid Check main valve solenoid resistance nominal is 60 ohms If open or shorted replace valve Verify valve inlet pressure is correct for gas type Pilot and main do not ligh...

Page 24: ...ed to operate your fireplace For safety Install a switch lock or a wall remote control with child protection lockout feature Keep remote controls out of reach of children See your dealer if you have q...

Page 25: ...S PART NUMBER Log Assembly LOGSDBDV36PLAT Y 1 Log A SRV2454 701 2 Log B SRV2454 702 3 Log C SRV2397 705 4 Log E SRV2454 705 5 Log D SRV2454 704 6 Log F SRV2454 706 7 Log G SRV2454 707 8 Log H SRV2397...

Page 26: ...og Assembly LOGSDBDV42PLAT Y 1 Log A SRV2454 701 2 Log B SRV2454 702 3 Log C Qty 2 req SRV2454 707 4 Log D SRV2397 702 5 Log E Qty 2 req SRV2454 704 6 Log F SRV2454 705 7 Log G SRV2454 706 8 Log H SRV...

Page 27: ...15 4 Valve Bracket 2118 104 15 5 Battery Pack SRV2326 134 Y 15 6 Power Supply SRV2326 131 Y 15 7 Flex Ball Valve Assembly SRV302 320 Y 15 8 Valve NG 2166 302 Y Valve Propane 2166 303 Y 15 9 Male Conn...

Page 28: ...45 Y Jumper Wire SRV2187 198 Y Lava Rock 4021 297 Mineral Wool SRV14333 Refractory Set Tavern Brown MERIDPLA36IN IL BRICK36MERTB MERIDPLA42IN IL BRICK42MERTB Refractory Set Cottage Red MERIDPLA36IN IL...

Page 29: ...____________________________ ________________________________________________________________________________ ________________________________________________________________________________ _________...

Reviews: