4
53D9028
c
leaRances
F
iguRe
2
USE ONLY
NON-COMBUSTIBLE
MATERIALS BELOW
TOP OF SPACERS
SIDE WALL INSTALLATION
LCL TELESCOPING
CHIMNEY CAP (1 REQUIRED)
METAL SAFETY STRIP
(REQUIRED WHEN PLACED
ON A COMBUSTIBLE FLOOR)
H2068 HEARTH
EXTENSION OR EQUIVALENT
(1 REQUIRED) WHEN PLACED
ON A COMBUSTIBLE FLOOR
(REFER TO PG. 11)
OUTSIDE INSTALLATION
2" MINIMUM CLEARANCE
TO COMBUSTIBLES
(EITHER SIDE)
LCF FLAT
FLASHING
SHOWN (OR EQUIVALENT)
L48 CHIMNEY
SECTION
(1 REQUIRED)
8 FT MIN.
CLEARANCE
AIR SPACE
1 1/2
16*
(MIN)
27 7/8
23 1/2
28
(MIN)
SCREENED OPENING
(MIN)
(MIN)
76 1/2
* APPLIES WHEN GLASS DOORS ARE INSTALLED
SAMPLE INSTALLATION
(FOR REFERENCE ONLY)
EXTERIOR FINISH
MATERIALS
REMOVED FOR CLARITY
TOP EDGE OF FIREPLACE
COMBUSTIBLE MANTEL
USE ONLY
NON-COMBUSTIBLE
MATERIALS BELOW
TOP OF SPACERS
COMBUSTIBLE FRAMING
MEMBERS TO
TOP OF SPACERS
12"
MAX
18" MIN. FROM FIREPLACE OPENING
TO BOTTOM OF COMBUSTIBLE MANTEL.
(MANUFACTURER RECOMMENDATION)
TOP EDGE OF
FIREPLACE OPENING
MANTEL INSTALLATION