This gas replace should be installed by a qualied installer 

in accordance with local building codes and with current CAN 

/CGA-B149 (. 1 or .2) Installation codes for Gas Burning 

Fireplaces and Equipment.  If the unit is being installed in a 

mobile home the installation should comply with the current 

CAN/CSA Z 240 .4 code.
FOR U.S.A Installations follow local codes and/or the current 

National Fuel Gas Code. ANSI Z223.1.

FOR SAFE INSTALLATION AND OPERATION PLEASE 

NOTE THE FOLLOWING:

1.  This replace gives off high temperatures and should be 

located out of high trafc areas and away from furniture 

and draperies.

2.  Children and adults should be alerted to the hazards of the 

high surface temperatures of this replace and should stay 

away to avoid burns or ignition of clothing.

3. 

Caution, due to high glass surface temperature children 

should be carefully supervised when they are in the same 

room as the replace.

4.  Under no circumstances should this replace be modied. 

Parts removed for servicing should be replaced prior to 

operating the replace again.

5.  Installation and any repairs to this replace should be 

carried out by a qualied service person. A professional 

service person should be contacted to inspect this replace 

annually. Make it a practice to have all of your gas re-

places checked annually.  More frequent cleaning may 

be required due to excess lint and dust from carpeting, 

bedding material, etc.

6.  Control compartments, burners and air passages in this 

replace should be kept clean and free of dust and lint. 

Make sure that the gas valve and pilot light are turned off 

before you attempt to clean this replace.

7.  The venting system (chimney) of this replace should be 

checked at least once a year and if needed your venting 

system should be cleaned.

8.  Keep the area around your replace clear of combustible 

materials, gasoline and other ammable vapour and liq-

uids. This replace should not be used as a drying rack for 

clothing, nor should Christmas stockings or decorations 

be hung on or around the replace.

9.  Under no circumstances should any solid fuels (wood, 

coal, paper or cardboard etc.) be used in this replace.

10.  The ow of combustion and ventilation air must not be 

obstructed in any way.

11.  When the replace is installed directly on carpeting, vinyl 

tile or any combustible material other than wood, the 

replace must be installed on a metal or wood panel 

extending the full width and depth of the replace.

12.  This replace requires adequate ventilation and combus-

tion air to operate properly.

13.  This replace must not be connected to a chimney ue 

serving a separate solid fuel burning replace.

14.  When the replace is not in use it is recommended that the 

gas control valve be left in the 

OFF

 position.

This appliance has been approved for 

after-market mobile home installations

IMPORTANT:

PLEASE REVIEW THE FOLLOWING CAREFULLY

Remove any plastic from trim parts before turning the 

replace 

ON

.

It is normal for replaces fabricated of steel to give off 

some expansion and/or contraction noises during the start 

up or cool down cycle. Similar noises are found with your 

furnace heat exchanger or car engine.

It is not unusual for your Majestic gas replace to give 

off some odour the rst time it is burned.  This is due to 

the curing of the paint and any undetected oil from the 

manufacturing process.

Please ensure that your room is well ventilated - open all 

windows.

It is recommended that you burn your Majestic replace for 

a least six (6) hours the rst time you use it.  If the optional 

fan kit has been installed, place the fan switch in the 

OFF

 

position during this time.

L

OCATING

 Y

OUR

 F

IREPLACE

A - Flat on the wall 

B - Cross corner

C - **Island 

D - *Room divider

E - *at on wall, corner 

F - Chase Installation

Note:

** Island (C) and room divider (D) installation is possible as 

long as he horizontal portion of the vent system (X) does not 

exceed 20' (6.1 m).  See the venting instructions for details
* When you install the appliance in a room divider (D) or at 

in a corner (E) you must have a minimum of 6" (152 mm) 

between the edge of the replace and the adjacent wall (Y).

Fig. 1

Summary of Contents for DVR33

Page 1: ...yourgas supplier from your neighbours phone Follow the gas suppliers instructions If you cannot reach your gas supplier call the re department WARNING IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED...

Page 2: ...nstallation 6 Remote switch installation 7 EB 1 electrical box connection 7 Converting the appliance from LP to Natural Gas 8 General Venting Information Terminal Location 10 Venting Installation Inst...

Page 3: ...eplace should not be used as a drying rack for clothing nor should Christmas stockings or decorations be hung on or around the replace 9 Under no circumstances should any solid fuels wood coal paper o...

Page 4: ...L L M N O P Q Appliance Dimensions DVR33 A 838 mm 33 B 733 mm 28 7 8 C 416 mm 16 3 8 D 787 mm 31 E 560 mm 22 1 16 F 292 mm 11 1 2 G 375 mm 14 3 4 H 622 mm 24 1 2 I 127 mm 5 J 191 mm 7 1 2 K 216 mm 8...

Page 5: ...ic purpose We recommend a non combustible hearth which projects out 12 305 mm or more from the front of the replace Cold climate Installation Recommendation When installing this unit against a non ins...

Page 6: ...ce as well as the bottom Knockouts are provided on the bottom behind the valve to allow for the gas pipe installation and testing of any gas connection It is most convenient to bring the gas line in f...

Page 7: ...the house electrical supply follow the steps below 1 Unscrew the retaining screw from the EB 1 base plate Fig 8 and remove the EB 1 assembly from the appliance 2 Remove the front cover of the EB 1 box...

Page 8: ...ori ce supplied in the kit Re t the pilot hood assembly Do not over tighten the pilot hood The hood must return to its original alignment Take care not to damage the thermocouple thermopile or ignite...

Page 9: ...10002823 0 DVR33 9 Vermont Castings Majestic Products Fig 10...

Page 10: ...nlet to building or the combustion air inlet to any other replace 12 inches 305mm minimum K clearance to a mechanical air supply inlet 72 inches 1828mm minimum L clearance above paved side walk or a p...

Page 11: ...combustible 2 50mm A Balcony with no side wall G Combustible Non Combustible 12 305mm G Balcony with perpendicular side wall H 24 610mm J 20 508mm H J B Recessed Location C Maximum depth of 48 1219mm...

Page 12: ...vent section used in the system To join the twist lock pipes together simply align the beads of the male end with the grooves of the female end then while bringing the pipes together twist the pipe u...

Page 13: ...all face plus 2 50 mm or the distance required if installing a second 90 elbow Fig 14 Step 4 Install the 4 100 mm vent to the appliance collar and secure with 3 sheetmetal screws Install the 7 175 mm...

Page 14: ...em maintain its balance between the combustion air intake and the ue gas exhaust certain limita tions as to vent con gurations apply and must be strictly adhered to The Sidewall Vent Graph showing the...

Page 15: ...gth in a system with a 7 5 vertical rise is 20 6 m and if a 90 elbow is required in the horizontal vent it must be reduced to 17 5 2 m In Fig 20 Dimension A plus B must not be greater than 17 5 2 m Th...

Page 16: ...attach a 90 transition elbow Ensure that the inner and outer elbow ends are concentric before attaching the vertical lengths of venting Place the replace into position Fig 24 Measure the vertical heig...

Page 17: ...ectly to the wall you may also use expanding plugs or an approved exterior construction adhesive You may also attach the termination with screws through the inner body into the 4 vent pipe however for...

Page 18: ...imum of 8 2 4 m of vent pipe can be used between elbows Fig 30 A 7DVCS bracket must be used to support offsets This application will require that you rst determine the roof pitch and use the appropria...

Page 19: ...into position and secure with screws or nails Fig 34 7 Install roof support Fig 32 and roof ashing making sure the upper ange of the ashing is under the shingles Fig 33 8 Install appropriate pipe sec...

Page 20: ...Vertical Installation Offsets 7TDR45 for Rear Vent Application 90 transition elbow kit 7TDVRT90 for Vertical Sidewall Applications or thru the roof Telescopic vent sections 7TDVP1218 12 to 18 adjustab...

Page 21: ...r Vertical Installation Offsets 7DV45 for Rear Vert Application 90 transition elbow kit 7DVRT90 for Vertical Sidewall Applications or thru the roof Telescopic vent sections 7DVP610 6 to 10 adjustable...

Page 22: ...htly dampened with lemon oil Do not use water or household cleaners on any brass components LOUVRE REMOVAL The top louvre panel is removed by lifting the panel vertically and pulling it away from the...

Page 23: ...ace The left end of this log rest on the outer edge of the burner housing the inner top fork rest across the cutout in the left rear log A23 and the inner front fork rest on the front edge of the burn...

Page 24: ...l gas go to the next step 7 Remove glass door before lighting pilot See Glass Frame Removal in manual 8 Visibly locate pilot by the main burner 9 Turn knob on gas control counter clockwise to PILOT ne...

Page 25: ...10002823 0 DVR33 25 Vermont Castings Majestic Products TROUBLE SHOOTING THE GAS CONTROL SYSTEM HONEYWELL MILLIVOLT VALVE...

Page 26: ...block not supplied must be used to conduct this test 3 Pilot burning no gas to A Wall switch or wires defective Check wall switch and wires for proper connections main burner Jumper wire across termin...

Page 27: ...4b Pilot assembly PSE Prop 10001740 5 Pilot SIT top convertible 10002266 6 Pilot PSE with cable and electrode 10001824 Pilot ori ce SIT Nat 10002268 Pilot ori ce SIT Prop 10002269 Pilot ori ce PSE Na...

Page 28: ...ssembly with bracket FK12 option ZA1110 20 Window frame assembly 10001803 21 Window glass with casket 10000961 Gasket window replacement kit 57317 22 Clamp window frame 54174 23 Window trim polished b...

Page 29: ...2823 0 DVR33 29 Vermont Castings Majestic Products PARTS PICTORIAL L O H I PILOT ADJ P I L O T ON OFF 1a 1b 1c 1d 1e 2 3a b 4a b 5 6 7 8 9 10 10 11 12 13 14 15 16a b 17a b 18 19 20 21 22 23 24 25 26 2...

Page 30: ...y fan system increases the ef ciency of the circu lation of the heating air The FK12 Fan Assembly is a xed speed fan system and does not allow for variable speed control It does not use the speed cont...

Page 31: ...er housing 5 Loosely attach the top adjustable tabs to the studs located in the top of the rebox toward the front corners 6 Place the rear refractory panel in place Locate the lower edge of the panel...

Page 32: ...play and a programmable 24 hour clock IMT Wall mounted thermostat control DECORATIVE FRAME TRIMS A selection of decorative frame trim kits is available for mounting around the outside of the appliance...

Reviews: