4.  Never install the fireplace 

• 

in a recreational vehicle

• 

where curtains, furniture, clothing, or other flammable 
objects are less than 42" from the front, top, or sides 
of the fireplace

  in high traffic areas

  in windy or drafty areas 

5.  This fireplace reaches high temperatures. Keep children 

and adults away from hot surfaces to avoid burns or 
clothing ignition. Fireplace will remain hot for a time after 
shutdown. Allow surfaces to cool before touching. 

6.  Carefully  supervise  young  children  when  they  are  in 

the room with fireplace. 

7.  Do not modify fireplace under any circumstances. Any 

parts removed for servicing must be replaced prior to 
operating fireplace. 

8.  Turn fireplace off and let cool before servicing, install-

ing, or repairing. Only a qualified service person should 
install,  service,  or  repair  the  fireplace.  Have  burner 
system  inspected  annually  by  a  qualified  service 
person. 

9.  You  must  keep  control  compartments,  burners,  and 

circulating air passages clean. More frequent cleaning 
may  be  needed  due  to  excessive  lint  and  dust  from 
carpeting, bedding material, pet hair, etc. Turn off the 
gas valve and pilot light before cleaning fireplace. 

10.  Have venting system inspected annually by a qualified 

service person. If needed, have venting system cleaned 
or repaired. Refer to 

Cleaning and Maintenance

, page 

41. 

11.  Keep the area around your fireplace clear of combus-

tible materials, gasoline, and other flammable vapor and 
liquids. Do not run fireplace where these are used or 
stored. Do not place items such as clothing or decora-
tions on or around fireplace. 

12.  Do not use this fireplace to cook food or burn paper or 

other objects.

13.  Never place anything on top of fireplace.

INSTaLLER

Please leave these instructions with the owner.

owNER

Please retain these instructions for future reference.

IMPoRTaNT SaFETy INFoRMaTIoN

This fireplace is a vented product. This fireplace must be 
properly installed by a qualified service person. The glass 
door must be properly seated and sealed. If this unit is not 
properly installed by a qualified service person with glass 
door properly seated and sealed, combustion leakage can 
occur. 

CaRBoN MoNoxIDE PoISoNING:

 Early signs of carbon 

monoxide poisoning are similar to the flu with headaches, 
dizziness and/or nausea. If you have these signs, the fire-
place may not have been installed properly. Get fresh air 
at once! Have the fireplace inspected and serviced by a 
qualified service person. Some people are more affected 
by carbon monoxide than others. These include pregnant 
women,  people  with  heart  or  lung  disease  or  anemia, 
those  under  the  influence  of  alcohol,  and  those  at  high 
altitudes. 
Propane/LP  gas  and  natural  gas  are  both  odorless. An 
odor-making agent is added to each of these gases. The 
odor helps you detect a gas leak. However, the odor added 
to these gases can fade. Gas may be present even though 
no odor exists.
Make certain you read and understand all warnings. Keep 
this manual for reference. It is your guide to safe and proper 
operation of this fireplace.
1.  This  appliance  is  only  for  use  with  the  type  of  gas 

indicated  on  the  rating  plate.  This  appliance  is  not 
convertible for use with other gases unless a certified 
kit is used. 

2.  For  propane/LP  fireplace,  do  not  place  propane/LP 

supply  tank(s)  inside  any  structure.  Locate  propane/
LP  supply  tank(s)  outdoors. To  prevent  performance 
problems, do not use propane/LP fuel tank of less than 
100 gal. capacity. 

3.  If you smell gas

• 

shut off gas supply.

• 

do not try to light any appliance.

• 

do not touch any electrical switch; do not use any 
phone in your building .

• 

immediately call your gas supplier from a neighbor’s 
phone. Follow the gas supplier’s instructions.

• 

Read this owner’s manual carefully and completely before trying to assemble, operate, 
or service this fireplace. 

• 

any change to this fireplace or its controls can be dangerous.

• 

Improper installation or use of this fireplace can cause serious injury or death from 
fire, burns, explosions, electrical shock and carbon monoxide poisoning.

w

a

RNING

Summary of Contents for DVDNV

Page 1: ...nstaller service agency or the gas supplier This appliance may be installed in an aftermarket permanently located manufactured home USA only or mobile home where not prohibited by local codes This app...

Page 2: ...rmination 24 Flat Ceiling Installation 24 Fireplace Installation 26 Check Gas Type 26 Installing Gas Piping 26 Checking Gas Pressure 28 Electrical Installation 28 Electrical Wiring 28 Remote Wall Swit...

Page 3: ...st be properly installed by a qualified service person The glass door must be properly seated and sealed If this unit is not properly installed by a qualified service person with glass door properly s...

Page 4: ...pe appliances draw all combustion air from outside of the dwelling through the vent pipe These appliances have been tested by CSA and found to comply with the established standards for DIRECT VENT GAS...

Page 5: ...in accordance with the current ANSI Z223 1 NFPA 54 and or local codes having jurisdiction In Canada please consult provincial and or local authorities having jurisdiction for installation at eleva ti...

Page 6: ...ims FIREPLACE DIMENSIONS Gas Electric Access See Through and Peninsula Model Dimensions STDVD PFDVD Rear Vent Shown 3256M 356M 18 6 4 6QE 39 6 2456O 1 6M 1956O 37 6M 405 6QE 5 8 1 2 44 37 6M 5 8 1 2 4...

Page 7: ...wood particle board or other hard surfaces Be sure firebox rests on a solid continuous floor or platform with appropriate framing for support No cold air should enter room from under the firebox FIREP...

Page 8: ...mounted flue pipe adaptor Refer to Page 16 Figures 10 and 11 Reattach both assemblies C A 2 B A 1 A1 A2 C FP2038 designer see thru framing 10 08 See through Framing Top View 2 x 4 Minimum Gas Connecti...

Page 9: ...appliance Figure 6 Mantel Clearances 2 4 6 8 10 4 6 8 10 12 FP2279 mantel clearance 2 09 Wall Insulation Board Standoff Top of Louvers FP2279 WARNING Never obstruct or modify the air inlet or outlet g...

Page 10: ...ng system chimney of this fireplace should be checked at least once a year and if needed your venting system should be cleaned 8 Keep the area around your fireplace clear of combus tible materials gas...

Page 11: ...ible Fireplace Locations FP2277 A Flat on Wall B Room Divider X X X A B Y Y Z A Y FP2277 locate fireplace SecurE fireplace to floor The fireplace must be secured to the floor and or to framing studs a...

Page 12: ...sket Figure 9 4 Remove eight 8 screws securing the flue pipe to the back of the intake box and remove the pipe and gasket Figure 10 5 Replace flue pipe to top of firebox Ensure the gasket is in place...

Page 13: ...oroughly before attempting installation Failure to do so could result in serious injury property damage or loss of life Operation of improperly installed and maintained venting system could result in...

Page 14: ...Installing Vent System in a Chase below If pipe is enclosed in chase it is not exposed It is very important that the venting system maintain its balance between the combustion air intake and the flue...

Page 15: ...mbly above the meter regulator assembly 5 m above the meter regulator assy I Clearance to service regulator vent outlet 3 91 cm 3 91 cm J Clearance to nonmechanical air supply inlet 6 15 cm for applia...

Page 16: ...m Example If the vertical dimension from the floor of the unit is 7 2 14m the horizontal run to the face of the outer wall must not exceed 8Z x 2 6 m Sidewall Vent Graph showing the relationship betwe...

Page 17: ...on the male end of adjacent pipes and fittings Push the pipe sections together and twist one section clockwise approximately one quarter turn until the sections are fully locked Figure 18 3 Attach ven...

Page 18: ...provided to attach the standoff Figure 20 5 Slide fire stop over the vent pipe before connecting hori zontal run to vent cap Figure 21 6 Insert vent pipe into the horizontal termination The pipe over...

Page 19: ...eplace in such a way that minimizes the number of offsets and horizontal vent length The horizontal vent run refers to the total length of vent pipe from the flue collar of the fireplace or the top of...

Page 20: ...s permitted per side wall installation is two 2 These elbows can be installed in either the vertical or horizontal run For each 45 elbow installed in the horizontal run the length of the horizontal ru...

Page 21: ...oil to a depth of approximately 16 below base of snorkel Install drain pipe Install window well not supplied Refill hole with 12 of coarse gravel leaving a clearance of approxi mately 4 below snorkel...

Page 22: ...horizontal length No elbows 10 3 m 1 x 45 elbows 8 5 2 6 m 2 x 45 elbows 7 2 1 m A minimum of an 8 2 5 m vertical rise is required Two sets of 45 elbows offsets may be used within the vertical sectio...

Page 23: ...e locating hole as a center point The opening should be framed to 9Z x x 9Z x 241 x 241 mm inside dimensions as shown in Figure 33 using framing lumber the same size as the ceiling joist If the area a...

Page 24: ...the top edge of the flashing There must be a 1 clearance from the vent pipe to combustible materials 6 Continue to add pipe sections until the height of the vent cap meets the minimum building code r...

Page 25: ...g gas pressure to between 11 and 13 inches of water If you do not reduce incoming gas pressure burner system regulator damage could occur Install external regulator with the vent pointing down as show...

Page 26: ...t you install a sediment trap drip leg in supply line as shown in Figure 36 Locate sediment trap drip leg where it is within reach for cleaning Install in piping system between fuel supply and burner...

Page 27: ...irmly to reseal Do not over torque Check test points for gas leaks Electrical Wiring This fireplace will work without any electrical supply Electricity is only needed to operate blower NOTE If install...

Page 28: ...switch wire length provided NOTE Extended lengths of wire may cause the fireplace not to function properly Longer length of wire is permitted if the wire is made out of larger gauge diameter wire Alw...

Page 29: ...the Millivolt hand held remote instruc tions supplied with the remote 1 Plug in remote connector wire to remote receiver 2 Connect the wire terminal from the remote receiver This replaces the 15 wall...

Page 30: ...e up until it clears three tabs on top of fireplace 3 Set glass frame aside FP2310 remove glass Figure 40 Remove Glass Frame Glass Frame Three Tabs Clamp Clamp FP2310 WARNING Each clamp has a quick sp...

Page 31: ...oves to prevent skin irritation from ceramic fibers After handling the logs wash your hands gently with soap and water to remove any traces of fibers LG639 Figure 42 Install Right Log 2 Right Log 2 Pi...

Page 32: ...3 Snug right end of bottom center back log 3 to the middle of right log 2 Figure 43 6 Line up pin holes on bottom front log 4 with pins on grate Figure 44 LG641 bottom front log Bottom Front Log 4 Pi...

Page 33: ...back of grate Position other end of top log 6 in cutout of bottom center log 3 Figure 46 Rock Wool L643 DV6000 top log Figure 46 Install Top Log 6 Top Log 6 Cutout on Bottom Center Log Grate Prong Fou...

Page 34: ...not back the screw all the way out 3 Slide the baffle on top of the restrictor plate to block a percentage of the grille opening Refer to the chart below for recommended settings Note All the setting...

Page 35: ...technician Force or attempted repair may result in a fire or explosion D Do not use this appliance if any part of it has been under water Immediately call a qualified service technician to inspect th...

Page 36: ...time when the magnet is closed it is possible to start the lighting operation The gas control knob is designed to be operated by hand DO NOT use any tools during this operation Damaged knobs may resul...

Page 37: ...s switch allows you to turn on and to turn off the main burner without using the gas valve knob Make sure the button is in the ON position to light the main burner Figure 50 Lighting the burner Depres...

Page 38: ...aners They will damage the glass surface pilot and burner flames firebox cleaning 1 Carefully remove log set and embers rock wool from combustion chamber 2 Vacuum burner compartment thoroughly 3 Vacuu...

Page 39: ...thermocouple connec tion at the gas valve is fully inserted and tight Disconnect the thermocouple from the valve place one millivolt lead wire on the tip of the thermocouple and the other meter lead...

Page 40: ...fices blocked B Check electrical connections between module and pilot operator on gas control C Check for 24VAC across PV MVPV terminals If voltage is correct replace gas control If voltage is not cor...

Page 41: ...ctor and air intake area Make sure this area does not have any blockage from debris and clean Check gas supply A Ensure that the vent cap is installed properly and free of debris Ensure that the vent...

Page 42: ...ally approved with this appliance may result in property damage or personal injury Ref Description Qty Natural Propane 1 Left Bottom Log 1 1 42D0401 42D0401 2 Right Bottom Log 2 1 42D0400 42D0400 3 Bo...

Page 43: ...ural Propane 1 Junction Box 1 26D2128K 26D2128K 2 Large Glass Assy 1 42D0364K 42D0366K Peninsula See through 2 Large Glass Assy 1 42D0366K 42D0366K Corner Left Corner Right 3 Small Glass Assy 1 42D036...

Page 44: ...1D0048 41D0048 5 Piezo Igniter 1 14D0503 14D0503 6 Injector 1 37D0362 37D0362 7 Burner Assy 1 42D0351 42D0351 8 Wire Assy Female 1 44D0500 44D0500 8 Wire Assy Male 1 44D0501 44D0501 Accessories 9 Ther...

Page 45: ...17 2 Pilot Assy 1 37D0020 37D0021 3 Flexhose w Shut off Valve 1 69D0030 69D0030 4 Rocker Switch 1 41D0048 41D0048 5 Injector 1 37D0362 37D0349 6 Burner Assy 1 42D0351 42D0351 7 Wire Assy 1 54D2001 54D...

Page 46: ...90 Elbow and BHSTK 11 x 14B Adjustable Pipe 1 1 Horizontal Flexible Pipe Termination Kit w Horizontal Termination Cap w BHSFTK Built in Vinyl Siding Standoff Heat Deflector Firestop 20 to 40 Flexible...

Page 47: ...53D0419 Designer Series Gas Fireplaces 47...

Page 48: ...48 53D0419 Designer Series Gas Fireplaces...

Page 49: ...53D0419 Designer Series Gas Fireplaces 49...

Page 50: ...omply with the above requirements provided however that during said thirty 30 day period a battery operated carbon monoxide detector with an alarm shall be installed Massachusetts Residents Only Pleas...

Page 51: ...ifetime Warranty will also be void if the appliance is not operated and maintained according to the operating instructions supplied with the appliance and does not extend to 1 firebox burner assembly...

Page 52: ...s Model EnerGuide Ratings Fireplace Efficiency STDVDNV 62 8 PFDVDNV 62 8 CRDVDNV 62 8 CLDVDNV 62 8 STDVDPV 70 6 PFDVDNV 70 6 CRDVDPV 70 6 CLDVDPV 70 6 STDVDNE 65 1 PFDVDNE 65 1 CRDVDNE 65 1 CLDVDNE 65...

Reviews: