3.6.7.
Calibration of the water temperature measurement
→
If the temperature sensor is disabled, the menu below does not appear.
Menu
Possible settings
Default setting
Parameters
Temp. Adjust
From - to + 5°C compared to the measurement displayed,
in increments of 0.5.
Measurement displayed
3.6.8.
Calibration of the salt rate measurement
→
If the salt sensor is disabled, the menu below does not appear.
Menu
Possible settings
Default setting
Parameters
Salt Adjust
From 1.5 to 8 g/L, in increments of 0.5.
Measurement displayed
3.6.9.
Calibration of the pH measurement
Menu
Possible settings
Default setting
pH Regulation
Adjust
From 6.5 to 7.5, in increments of 0.1.
Measurement displayed
3.6.10.
Setting the inversion frequency of the current supplying the cell
I
Current inversion aims to prevent scale deposits on the cell. Current inversion must be set following the table
below in order to ensure that the cell continues to operate correctly in the long term.
Water hardness (°f)
0 to 5
5 to 12
12 to 20
20 to 40
40 to 60
> 60
Inversion frequency (h)
16
10
8
6
4
2
Menu
Possible settings
Default setting
Electrolysis
Inversion XX h
From 2 to 24 h, in increments of 1.
6 h
3.6.11.
Selecting the chlorinator operating mode
Menu
Possible settings
(depending on model)
Meaning
Default setting
Electrolysis
Mode XXX
%
Continual production, following the
production setpoint.
•
For
UNO
and
DUO
models : %.
•
For
PRO
model : ORP.
ORP
Inspection of production using the
ORP probe, according to the ORP
setpoint and the ORP production
setpoint.
OFF
Deactivation of the chlorinator cell.
→
The choice of operating mode can be seen on the initial display («
PROD
» as a %, or «
ORP
» in mV).