background image

23

Majestic Fireplaces

®

 ODSR Series "A"

20006811

LIMITED WARRANTY

Factory-Build Fireplace and Components

(Except Blowers)

What is Covered and For How Long

Five-Year Coverage:

 For five years from the date this fireplace and components are first purchased for use, MHSC 

will, at its option, repair or replace any defective part of this fireplace or components, or refund to you a sum not to 
exceed the factory retail price in effect at the time of purchase.

Ten-Year Coverage:

 From the sixth through the tenth year following the date this fireplace or accessory is first 

purchased for use, MHSC will make available to you, at our factory, a free replacement for any defective part in this 
fireplace or accessory.

Twenty-Five-Year Availability of Replacement Parts:

 From the eleventh through the twenty-fifth year following the 

date this fireplace or accessory is first purchased for use, MHSC will make available at our factory replacement parts 
for this fireplace or accessory, which you may purchase for the list price current at the time your purchase order is 
received.

What is Not Covered

•  This limited warranty does not cover:
•  Transportation or shipping cost.
•  The cost of a service call to diagnose trouble.
•  Painted surfaces.
•  Damage or defect caused by improper installation, accident, misuse, abuse or alteration.
•  Poor ventilation of smoke or gases caused by air-conditioning and heating systems, exhaust fans, or pressure dif-

ferentials produced by wind.

•  Broken glass components.
•  Cracks in ceramic and castable parts that do not affect safe operation.
•  We do not warrant this fireplace to be in compliance with your local building code. Building codes vary greatly 

throughout the country, and you should determine whether your local building code contains restrictions on the use 
of this fireplace before you purchase it.

•  Blowers or fans, which are warranted separately.
•  Heat loss due to the passage of heat or air through or around the fireplace.
Also, under our five year coverage, we do not pay the cost of removal and replacement of any portion of the structure 
in which the fireplace is situated, made necessary by the repair, removal or re-installation of the fireplace.
And under our twenty-five year warranty of availability of replacement parts, we only promise to maintain a supply of 
replacement parts at our factory for you to purchase.

Limitations and Exclusions

1.  No one has authority to add to or vary this limited warranty, or to create for MHSC any other obligations of liability 

in connection with this fireplace and accessory.

2.  MHSC shall not be liable for incidental, consequential, special or contingent damages you might suffer as a result 

of its breach of this written warranty or any implied warranty. Some states do not allow the exclusion of limitation of 
incidental or consequential damages, so the above limitations may not apply to you.

3.  This warranty applies only to a fireplace sold and used in the United States.
For information about this warranty, contact:
 

MHSC

 

149 Cleveland Drive

 

Paris, Kentucky  40361

Summary of Contents for Al Fresco ODSR36A

Page 1: ...eplace For Models ODSR36A ODSR42A 948 SR cover 11 18 97 For use in U S Canada Underwriter s Laboratories Report No MH6018 20006811 8 08 Rev 7 DO NOT DISCARD THIS MANUAL Retain for future use Homeowner...

Page 2: ...ips Securing the Fireplace 11 Installing Outside Air Kit 12 Installing the Chimney System 12 Finishing 14 Side Wall Protection 16 Hearth Installation 16 Installing Line for Gas Logs 18 Replacement Par...

Page 3: ...ound Burn only solid wood fuel or gas logs Do not install a solid fuel burning insert or other products not speci ed for use with this replace These replaces are not approved for installation in mobil...

Page 4: ...210 mm 22 559 mm 22 572 mm 26 667 mm 43 1111 mm 14 372 mm 11 279 mm 8 203 mm 7 191 mm Outside Air Gas Line Access 8 Dia 203 mm 3 6 9 1 4 m m ODSR36A Series Woodburning Fireplace Fig 1 ODSR36A speci c...

Page 5: ...climate not a requirement for unit operation or exterior installation FP554 Fig 5 Fireplace and chase parts identi cation Termination Cap Storm Collar Pan Flashing Batt Insulation cut out around rest...

Page 6: ...Min NOTE If the replace is a freestanding unit it must be located a minimum of 10 3 m from the opening of the rebox to a combustible structure A minimum height of 6 4 1 9 m measured from the base of...

Page 7: ...42A Maximum 90 0 90 0 Minimum Without Elbows 12 6 12 6 With 2 Elbows 14 6 14 6 With 4 Elbows 21 0 21 0 B Do not use more than 4 elbows per chimney Attach the straps of the return top elbow to a struct...

Page 8: ...un Determine how the chimney will be run length of run and chimney components required to complete the job Fig 6 Never install a chimney below minimum heights In planning a chimney system it is import...

Page 9: ...your Majes tic Fireplaces dealer for assistance FP284 Fig 10 Chimney support installation FP284 MBUF 5 25 96 Chimney Sup port Strap SKCS8 Insulating Fireplace Enclosure for Cold Climates If you live...

Page 10: ...plumb bob positioned directly over center point of replace ue collar mark the ceiling to establish the chimney center point Fig 12 Offset Installation In order to clear an obstruction it may be necess...

Page 11: ...trips Securing the Fireplace Slide replace into position Lift the replace front slightly and slide the metal safety strips under front bottom edge about 1 38 mm al lowing the remainder to extend in fr...

Page 12: ...restop spacer Installing the Firestop Spacer in the Ceiling Hole A restop spacer is used to keep pipe spaced properly and required for safety Nail the restop spacer at each corner to the framing membe...

Page 13: ...used in long runs in a chase installation Additional Ceilings If you encounter additional ceilings repeat same steps required for rst ceiling installation Refer to restop illustration on Figure 19 Pen...

Page 14: ...be sealed with non combustible material to prevent cold air leakage into the room Only noncombustible material may be applied to the facing of the replace surround Black painted area Fig 21 Finish Wal...

Page 15: ...urround to bottom of screen rail Finished Wall Header Standoff Noncombustible Material Radiant Surround Face Noncombustible Facing Material Radiant Surround Face 2 x 4 Stud Finished Wall Must be seale...

Page 16: ...92 mm 508 mm 1562 mm Side Wall Protection Adjacent combustible side walls that are within the mini mum dimensions shown in Figure 24 of replace open ing must be protected with MHSC Wall Shield Model S...

Page 17: ...ne the thickness required for any new mate rial NEW K of new material per inch Thickness required X of listed thickness K of listed material per inch material Example for Common Brick T new 5 0 0 458...

Page 18: ...of re place and remove insulation from gas line tube Fig 27 From inside the replace locate the knockout on the rebrick be sure you are on the appropriate or gas line side of the replace Using a at bl...

Page 19: ...2225 6a Firebrick Hearth 20005621 20005421 6b Firebrick Rear 20005627 20005462 6c Firebrick Right Side 20005626 20005461 6d Firebrick Left Side 20005625 20005460 6e Firebrick Ashlip 20005619 20005418...

Page 20: ...d Mantels available in a wide selection of styles Accessory Descritpion Model Number Glass Door Standard Bi Fold set Brushed Brass nish 36GDKBBSR ODSR36A recommended for indoor use 42GDKBBSR ODSR42A B...

Page 21: ...propriate adapter required Flashing not included Adapter Kit Unites Square Chase Termination with chimney CTSK pipe required for CT100 cap Chase Top Housing Low pro le pyramid style chimney cap used t...

Page 22: ...o assist in cooling the chimney system Attic Insulation Shield Used to prevent insulation from coming in AIS SK contact with the chimney system 45 Chimney Elbows Provides 45 offset and return For Cana...

Page 23: ...e dif ferentials produced by wind Broken glass components Cracks in ceramic and castable parts that do not affect safe operation We do not warrant this replace to be in compliance with your local buil...

Page 24: ...MHSC 149 Cleveland Drive Paris Kentucky 40361 www mhsc com...

Reviews: