background image

20

Majestic Fireplaces

®

 ODSR Series "A"

20006811

The following accessories for this appliance are available from your local Majestic distributor. Should you need addi-
tional information beyond what your distributor can furnish, contact: MHSC, 149 Cleveland Drive, Paris, KY  40361, 
Attn:  Technical Services.

CAUTION: This fireplace and chimney assembly is a highly engineered system, and, as such, must be oper-
ated only with MHSC approved components.  If you use an unapproved component to make any modifica-
tions, you may create a possible fire hazard and will void the MHSC warranty.  In addition, such action may 
void the coverage provided by the owner’s insurance. 

Accessories

Contact your Majestic distributor or dealer for finishing Marble and 
Mantels, available in a wide selection of styles.

 

Accessory 

Descritpion 

Model Number

  Glass Door - Standard 

Bi-Fold set 

 

Brushed Brass finish 

36GDKBBSR (ODSR36A)

   

 

(recommended for indoor use)

 

42GDKBBSR (ODSR42A)

   

 

 

Black finish 

36GDKBKSR (ODSR36A)

   

 

(recommended for indoor use)

 

 42GDKBKSR (ODSR42A)

   

 

 

Polished Brass finish 

36GDKDBSR (ODSR36A)

   

 

(recommended for indoor use)

 

 36GDKDBSR (ODSR42A)

   

 

 

Pewter finish 

36GDKSSR (ODSR36A)

   

 

(recommended for indoor use)

 

 42GDKSSR (ODSR42A)

   

 

 

Stainless Steel 

36GDKSSSR (ODSR36A)

   

 

(recommended for outdoor use)

   42GDKSSSR (ODSR42A)

  Outside Air Kit 

Complete kit for connection from fireplace 

AKU1 

   

 

 

   

to out-of-doors

  Chimney Adapter 

Converts fireplace to 3-wall system 

TWABR

  Hearth Extension Insulation 

Provides hearth extension floor prtesi 

EH2416

  Hearth Patch Compound 

Patch cracks in hearth 

HPC-1

  Drain Pan 

Designed to be installed under unit to  

20014194 (36" models)

   

shed water by means of containing and 

20014195 (42" models)

   

piping away from structure.

Summary of Contents for Al Fresco ODSR36A

Page 1: ...eplace For Models ODSR36A ODSR42A 948 SR cover 11 18 97 For use in U S Canada Underwriter s Laboratories Report No MH6018 20006811 8 08 Rev 7 DO NOT DISCARD THIS MANUAL Retain for future use Homeowner...

Page 2: ...ips Securing the Fireplace 11 Installing Outside Air Kit 12 Installing the Chimney System 12 Finishing 14 Side Wall Protection 16 Hearth Installation 16 Installing Line for Gas Logs 18 Replacement Par...

Page 3: ...ound Burn only solid wood fuel or gas logs Do not install a solid fuel burning insert or other products not speci ed for use with this replace These replaces are not approved for installation in mobil...

Page 4: ...210 mm 22 559 mm 22 572 mm 26 667 mm 43 1111 mm 14 372 mm 11 279 mm 8 203 mm 7 191 mm Outside Air Gas Line Access 8 Dia 203 mm 3 6 9 1 4 m m ODSR36A Series Woodburning Fireplace Fig 1 ODSR36A speci c...

Page 5: ...climate not a requirement for unit operation or exterior installation FP554 Fig 5 Fireplace and chase parts identi cation Termination Cap Storm Collar Pan Flashing Batt Insulation cut out around rest...

Page 6: ...Min NOTE If the replace is a freestanding unit it must be located a minimum of 10 3 m from the opening of the rebox to a combustible structure A minimum height of 6 4 1 9 m measured from the base of...

Page 7: ...42A Maximum 90 0 90 0 Minimum Without Elbows 12 6 12 6 With 2 Elbows 14 6 14 6 With 4 Elbows 21 0 21 0 B Do not use more than 4 elbows per chimney Attach the straps of the return top elbow to a struct...

Page 8: ...un Determine how the chimney will be run length of run and chimney components required to complete the job Fig 6 Never install a chimney below minimum heights In planning a chimney system it is import...

Page 9: ...your Majes tic Fireplaces dealer for assistance FP284 Fig 10 Chimney support installation FP284 MBUF 5 25 96 Chimney Sup port Strap SKCS8 Insulating Fireplace Enclosure for Cold Climates If you live...

Page 10: ...plumb bob positioned directly over center point of replace ue collar mark the ceiling to establish the chimney center point Fig 12 Offset Installation In order to clear an obstruction it may be necess...

Page 11: ...trips Securing the Fireplace Slide replace into position Lift the replace front slightly and slide the metal safety strips under front bottom edge about 1 38 mm al lowing the remainder to extend in fr...

Page 12: ...restop spacer Installing the Firestop Spacer in the Ceiling Hole A restop spacer is used to keep pipe spaced properly and required for safety Nail the restop spacer at each corner to the framing membe...

Page 13: ...used in long runs in a chase installation Additional Ceilings If you encounter additional ceilings repeat same steps required for rst ceiling installation Refer to restop illustration on Figure 19 Pen...

Page 14: ...be sealed with non combustible material to prevent cold air leakage into the room Only noncombustible material may be applied to the facing of the replace surround Black painted area Fig 21 Finish Wal...

Page 15: ...urround to bottom of screen rail Finished Wall Header Standoff Noncombustible Material Radiant Surround Face Noncombustible Facing Material Radiant Surround Face 2 x 4 Stud Finished Wall Must be seale...

Page 16: ...92 mm 508 mm 1562 mm Side Wall Protection Adjacent combustible side walls that are within the mini mum dimensions shown in Figure 24 of replace open ing must be protected with MHSC Wall Shield Model S...

Page 17: ...ne the thickness required for any new mate rial NEW K of new material per inch Thickness required X of listed thickness K of listed material per inch material Example for Common Brick T new 5 0 0 458...

Page 18: ...of re place and remove insulation from gas line tube Fig 27 From inside the replace locate the knockout on the rebrick be sure you are on the appropriate or gas line side of the replace Using a at bl...

Page 19: ...2225 6a Firebrick Hearth 20005621 20005421 6b Firebrick Rear 20005627 20005462 6c Firebrick Right Side 20005626 20005461 6d Firebrick Left Side 20005625 20005460 6e Firebrick Ashlip 20005619 20005418...

Page 20: ...d Mantels available in a wide selection of styles Accessory Descritpion Model Number Glass Door Standard Bi Fold set Brushed Brass nish 36GDKBBSR ODSR36A recommended for indoor use 42GDKBBSR ODSR42A B...

Page 21: ...propriate adapter required Flashing not included Adapter Kit Unites Square Chase Termination with chimney CTSK pipe required for CT100 cap Chase Top Housing Low pro le pyramid style chimney cap used t...

Page 22: ...o assist in cooling the chimney system Attic Insulation Shield Used to prevent insulation from coming in AIS SK contact with the chimney system 45 Chimney Elbows Provides 45 offset and return For Cana...

Page 23: ...e dif ferentials produced by wind Broken glass components Cracks in ceramic and castable parts that do not affect safe operation We do not warrant this replace to be in compliance with your local buil...

Page 24: ...MHSC 149 Cleveland Drive Paris Kentucky 40361 www mhsc com...

Reviews: